Anolis Ambiane™ User manual

Category
Stroboscopes & disco lights
Type
User manual
1
User manual
Ambiane RGBW
The unit generates colored light by means of high power LEDs. The product was designed for indoor use only.
1. Attention
Theunitmustbeinstalledbyaqualiedelectricianinaccordancewithall
national and local electrical and construction codes and regulations.
The unit was designed for indoor use only.
Avoid looking directly into the LED light beam at close range!
Donotinstalltheunitnearhighlyinammableliquidsormaterials.
Do not allow anything to rest on the unit.
Donotinstalltheunitnearanopename.
Do not install the unit in dirty,dusty or badly ventilated location.
Sucientairaccessingtothehousingoftheunithastobeensured,
there must not be any heat or anti-noise insulation within a 0.6m x 0.6m
areaaroundtheunit(non-ICratedxture).
Suitable for fastening on Unsuitable for covering by heat insulation
non-ammablesurfacesonly material
2. Installation
1.Prepareacircularopeninginthelowerceiling(1)asshowninthepicturebelow.
2.InserttheAmbianeunitintotheopening.Fastenthexturebymeansoftwospringfasteners(2)totheopening
Alvays switch o power suply of the unit before connecting or disconnecting the unit
2
Toconnectneededcablestothexture,unscrewtwoscrews(4)fromtheplasticcover(3)andchipneeded
plasticthin-walledcovers(6)oinordertopasscablestotheconnectionblocks(5).
Theconnectionblocks(5)havethefollowingwiring:
Theprimarypowerinputservesforastandardpower(e.g.ArcPowerforAmbiane).
Thesecondarypowerinputservesforabackuppower(incasethatprimarypowerfailed).
If both power inputs are under voltage, the primary power has a priority and the secondary power is disabled.
In case of primary power loss, the secondary power is enabled.
Ifthextureissuppliedviathesecondarypower,thelightoutputofthextureisawhitecolour(3200K)andits
light intensity can be set by a trimmer.
Thexturecanbecontrolledbyoneofthefollowingmethods:DMX512
DALI
ThextureisequippedwithtwoDMXandDALIconnectionblocksforeasyconnectiontoDMXorDALIchain
(In/Outmethod).
DMX connection Power connection
PCB Function PCB Function
0V - Shield + Power +
D+ Signal(+) - Power-
D- Signal(-)
3. DMX and DALI address setting and control
TheDIPswitch,locatednexttotheconnectionblocks,allowsyou,runatestlightandswitchthexturetothe
update mode in case of software update.
.
3
DIP10-ifswitchedtoON=testlight(thexturelightsat3200K)
DIP11-hastobeswitchedtoOFFpositiontoreceiveDMX512orDALI
DIP12-changefromOFFtoONpositionswitchesthexturetotheupdatemode.
DMX control
TheDMXstartaddress,istherstchannelusedtoreceiveinstructionsfromtheDMXcontroller.Theaddress
maybeanychannelfrom1to509.DMXaddresscanbeseteitherbyDIPswitchorbyRDM.DMXaddress
setbyRDMoverwritesaddresssetbyDIPswitchandviceversa.ThegreenLEDonPCBsignalswayofDMX
addresssetting:
LEDlights-DMXaddressissetbymeansoftheDIPswitch.
LEDdoesnotlight-DMXaddressissetbymeansofRDM.
DIP 11 has to be set in OFF position.
ExampleofDMXaddresses:
DALI control
AddressingofthextureismadebymeansofanexternalDALIcontroller.TheexternalDALIcontrollerhasto
sendactivatingcommand(8=ON)ifyouneedtostartthepermanentcontrolofthexture(xturewillnotrespond
toDMXcommands)anddeactivatingcommand(0=OFF)tostopcontrolofthexture.
DIP 11 has to be set in OFF position.
Note:IfDIP11=OFF(xtureiscontrolledbyDMXorDALI),therstcomingcommandswitchesthexturetothe
correspondingoperationmode(DMXoperationbyaDMXcommand,DALIoperationbyaDALIcommand).E.g.
thexturestaysinaDALIoperationandcomingDMXcommandswitchesthexturetoDMXoperation.Next
commandisaDALIcommandandswitchesthexturetotheDALIoperationetc.Ifyouneedthepermanent
DALIoperation,youhavetosendaDALIcommand8tothexture.
4. RDM
ThisxturesupportsRDMoperation.RDM(RemoteDeviceManagement)isabi-directionalcommunication
protocolforuseinDMX512controlsystems,itisthenewopenstandardforDMX512devicecongurationand
status monitoring.
RDMallowsyoutosetaDMXaddress,selectDMXmodeandreadoutsoftwareversionofthexture.
4
5. Anti-glare ring installation
Inserttheanti-glarering(1)intothextureuntilthreelocks(2)snapintoslots(3).
6. Adapter ring installation
1.Removebothspringfasteners(2)byunscrewingthefourscrewsM4x10(1).
2.Slidetheadapterring(4)ontothehousingofthexture.Screwthenewfasteners(3)onthehousing.
UseoriginalscrewsM4x10(1).
5
7. DMX protocol
Version 1.1
Mode 1
Channel
Mode 2
Channe
Mode 3
Channe
Value Function Type of control
1 1 1
0-255
Red
RedLEDssaturationcontrol(0-100%) proportional
- - 2
0-255
Red Fine
RedLEDssaturationcontrolfrommin.-->max. proportional
2 2 3
0-255
Green
GreenLEDssaturationcontrol(0-100%) proportional
- - 4
0-255
Green Fine
GreenLEDssaturationcontrolfrommin.-->max. proportional
3 3 5
0-255
Blue
BlueLEDssaturationcontrol(0-100%) proportional
- - 6
0-255
Blue Fine
BlueLEDssaturationcontrolfrommin.-->max. proportional
4 4 7
0-255
White
WhiteLEDssaturationcontrol(0-100%) proportional
- - 8
0-255
White Fine
WhiteLEDssaturationcontrolfrommin.-->max. proportional
- 5 9
0-255
Dimmer
Lightintensitycoarse0%-->100% proportional
- 6 10
0-255
Dimmer Fine
Lightintensityfrommin.-->max. proportional
8. Technical specications
Inputvoltage: 24VDC
Protectionclass: CE: (ClassIII)
ETL:Class2orLVLE
Max.powerconsumption: 40W
Beamangle: 67°,80°,withanti-glarering
Control: DMX,DALI,RDMcompatible
DMXchannels: 4(Mode1),6(Mode2),10(Mode3)
TypicalLumenmaintenance: 70%@50,000hours
Ledlifeexpectancy: minimum50,000hours
Operatingambienttemp.range:  -20°C/+45°C(-4F/+113F)
Operatingtemperature: 75°C@Ambient+35°C(167°F@Ambient+95°F)
Totalheatdissipation: 136BTU/h(calculated)
Cooling: convection
Totalheatdissipation: 136BTU/h(calculated)
Housing: alluminium
Weight: 1.8kg
Installationmethod: viatwospringfasteners
ICrating: non-ICrated
Power/DMX/DALIconnection: screwconnectionblockDegsonDG306-5.0-02P
(Wirerange:22-14AWG(UL),1.5mm
2
(IEC))
Max.distancebetweenAmbianeand
ArcPowerforAmbiane: 1m(for2x18AWGcable)
Protectionfactor: IP20(withoutdiuserglass),IP20/IP54(withDiuserGlass)
6
AmbianewithoutDiuserGlass AmbianewithDiuserGlass
9. Optional Accessories
ArcPower for Ambiane
Anti-GlareRing(P/N10980386)
DiuserGlassFrosted(P/N10980387)
AdapterRing(230-255mm)(P/N10980388)
10. Maintenance
Keepthextureclean,especiallylightsourceandtheribbedhousing.
7
11. Dimensions
mm [inch]
Version2.1May11,2018
Specications are subject to change without notice.
Made in CZECH REPUBLIC by ROBE LIGHTING s.r.o. Palackeho 416/20 CZ 75701 Valasske Mezirici
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Anolis Ambiane™ User manual

Category
Stroboscopes & disco lights
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI