HP D6000 User manual

Category
Disk arrays
Type
User manual
HP D6000 Disk Enclosure
User Guide
Abstract
This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, specifications, and technical
support. This guide is for an ex
perienced service technician. HP assumes that you are qualified in the servicing of computer equipment, trained in
recognizing hazards in products and are familiar with weight and stability precautions.
Part Number: 682254-001
September 2012
Edition: 1
© Copyright 2012 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Bluetooth® is a trademark owned by its proprietor and used by Hewlett-Packard Company under license.
Microsoft® and Windows® are U.S. registered trademarks of Microsoft Corporation.
Contents 3
Contents
Component identification ............................................................................................................... 5
Front panel components ............................................................................................................................. 5
Front panel LEDs and buttons ...................................................................................................................... 6
Rear panel components .............................................................................................................................. 7
Rear panel LEDs and buttons ....................................................................................................................... 8
Device bay ID numbers ............................................................................................................................ 10
Hard drive LEDs ...................................................................................................................................... 10
Hard drive LED combinations .................................................................................................................... 11
Operations ................................................................................................................................. 12
Firmware update ..................................................................................................................................... 12
Powering up ........................................................................................................................................... 12
Power down ........................................................................................................................................... 13
Setup ......................................................................................................................................... 14
Space and airflow requirements ................................................................................................................ 14
Temperature requirements ........................................................................................................................ 14
Power requirements ................................................................................................................................. 15
Electrical grounding requirements .............................................................................................................. 15
Rack warnings ........................................................................................................................................ 16
Third-party racks ..................................................................................................................................... 16
Site planning considerations ..................................................................................................................... 16
Installing the enclosure ............................................................................................................................. 16
Installing the hard drives .......................................................................................................................... 18
Installing optional I/O modules ................................................................................................................. 21
Cabling the D6000 ................................................................................................................................. 23
Mini-SAS I/O cables ...................................................................................................................... 23
Power cords .................................................................................................................................. 23
Configuration and utilities ............................................................................................................ 24
Configuration tools .................................................................................................................................. 24
Array Configuration Utility .............................................................................................................. 24
Option ROM Configuration for Arrays ............................................................................................. 24
Smart Components for ROM Flash ................................................................................................... 25
Management tools ................................................................................................................................... 25
HP Systems Insight Manager ........................................................................................................... 25
Management Agents ...................................................................................................................... 25
Diagnostic tools ...................................................................................................................................... 25
Integrated Management Log ........................................................................................................... 25
Array Diagnostic Utility .................................................................................................................. 26
Remote support and analysis tools ............................................................................................................. 26
HP Insight Remote Support software ................................................................................................. 26
Keeping the system current ....................................................................................................................... 27
Change control and proactive notification ........................................................................................ 27
Care Pack .................................................................................................................................... 27
Troubleshooting
.......................................................................................................................... 28
When the D6000 does not power up ........................................................................................................ 28
Contents 4
LED behavior .......................................................................................................................................... 28
7-segment display status codes and actions....................................................................................... 29
Recognizing hard drive failure .................................................................................................................. 30
Effects of a hard drive failure .......................................................................................................... 31
Compromised fault tolerance .......................................................................................................... 31
Recovering from compromised fault tolerance .................................................................................... 31
Factors to consider before replacing hard drives ......................................................................................... 32
Automatic data recovery (rebuild) .............................................................................................................. 32
Time required for a rebuild ............................................................................................................. 33
Failure of another drive during rebuild ............................................................................................. 33
Regulatory compliance notices ..................................................................................................... 34
Regulatory compliance identification numbers ............................................................................................. 34
Federal Communications Commission notice ............................................................................................... 34
FCC rating label ............................................................................................................................ 34
Class A equipment......................................................................................................................... 34
FCC Notice, Class B Equipment ...................................................................................................... 35
Declaration of conformity for products marked with the FCC logo, United States only ....................................... 35
Modifications .......................................................................................................................................... 36
Cables ................................................................................................................................................... 36
Canadian notice (Avis Canadien) .............................................................................................................. 36
European Union regulatory notice ............................................................................................................. 36
Disposal of waste equipment by users in private households in the European Union ......................................... 37
Japanese notice ...................................................................................................................................... 38
BSMI notice ............................................................................................................................................ 38
Korean notice ......................................................................................................................................... 38
Chinese notice ........................................................................................................................................ 39
Vietnam compliance marking notice .......................................................................................................... 39
Ukraine notice ........................................................................................................................................ 39
Power cord statement for Japan ................................................................................................................. 39
Electrostatic discharge ................................................................................................................. 40
Preventing electrostatic discharge .............................................................................................................. 40
Grounding methods to prevent electrostatic discharge .................................................................................. 40
Specifications ............................................................................................................................. 41
Environmental specifications ..................................................................................................................... 41
Storage array specifications ..................................................................................................................... 41
Support and other resources ........................................................................................................ 42
Before you contact HP .............................................................................................................................. 42
HP contact information ............................................................................................................................. 42
Customer Self Repair ............................................................................................................................... 42
Acronyms and abbreviations ........................................................................................................ 50
Documentation feedback ............................................................................................................. 51
Index ......................................................................................................................................... 52
Component identification 5
Component identification
Front panel components
Item Description
1
Drawer 1
2
Drawer 1 diagnostic cable access (For use by authorized
HP personnel only)
3
Drawer 2
4
Drawer 2 diagnostic cable access (For use by authorized
HP personnel only)
Component identification 6
Front panel LEDs and buttons
Item Description Status
1
Hard drive LEDs
Normal mode
(UID LED is solid)
Green = The drive is online, but is not
currently active.
Flashing irregularly green = The drive is
active and it is operating normally.
Flashing green (1 Hz) = Do not remove
the drive. Removing the drive may
terminate the current operation and
cause data loss. The drive is rebuilding,
or it is part of an array that is undergoing
expansion, logical drive extension, a
stripe size migration, or RAID migration.
Flashing amber/green = Drive is
configured and indicating a predictive
failure. The drive may also be
undergoing a rebuild, expansion,
extension, or migration.
Flashing amber (1 Hz) = A predictive
failure alert has been received for this
drive. Replace the drive as soon as
possible.
Amber = Drive failure, link failure, or
mismatched configuration.
Off = The drive is offline, a spare, or not
configured as part of an array.
Component identification 7
Item Description Status
1
Hard drive LEDs
Drive locate mode
(UID LED is flashing)
Green = The drive has been selected by
a management application and it is
operating normally.
Flashing amber (1 Hz) = The drive is not
selected and is indicating a predictive
failure.
Flashing amber/green = The drive has
been selected by a management
application and is indicating a
predictive failure.
Amber = The drive might or might not be
selected and is indicating drive failure,
link failure, or mismatched
configuration.
Off = The drive is not selected.
2
UID button/LED Blue = UID LED is enabled from the UID
button
Blue flashing = Item 1 is in locate mode
Off = UID LED is disabled
3
Internal Health LED Green = System health is good
Off = System is off
4
GSI LED Amber = Enclosure requires service
check: I/O, fan and power supply LEDs,
and AC power cables to power supplies.
Off = Enclosure is functioning normally.
Rear panel components
The figure shows a maximum configuration. Your enclosure might appear differently, for example,
containing power supply or I/O module blanks, depending on the configuration that was ordered.
Item Description
1
Power supply 1
Component identification 8
Item Description
2
Power On/UID 2 status panel
3
Fan module 1 (Drawer 2)
4
Primary I/O module (Drawer 2)
5
SAS port 1 connector
6
SAS port 2 connector
7
Power supply 3
8
UID 1 status panel
9
Fan module 1 (Drawer 1)
10
Primary I/O module (Drawer 1)
11
SAS port 1 connector
12
SAS port 2 connector
13
SAS port 1 connector
14
SAS port 2 connector
15
Secondary I/O module (Drawer 1)
16
Fan module 2 (Drawer 1)
17
Power supply 4
18
SAS port 1 connector
19
SAS port 2 connector
20
Secondary I/O module (Drawer 2)
21
Fan module 2 (Drawer 2)
22
Power supply 2
Rear panel LEDs and buttons
Item Description Status
1
Power On/Standby button
and system power LED
Green = On
Amber = Standby (auxiliary power
present)
Off = Off
Component identification 9
Item Description Status
2
Internal Health LED Green = System health is good.
Off = System is off.
3
GSI LED* Amber = Enclosure requires service
check: I/O, fan and power supply LEDs,
and AC power cables to power supplies.
Off = Enclosure is functioning normally.
4
UID button/LED (Drawer 2) Blue = UID LED is enabled from the UID
button.
Blue flashing = System is in hard drive
locate mode or an enclosure firmware
update is in progress.
Off = UID LED is disabled.
5
Power supply LED Green = Power on and power supply
functioning properly
Off = One or more of the following
conditions exists:
System powered off
AC power unavailable
Power supply failed
Power supply exceeded current limit
6
System fan LED Green = Normal operation
Amber flashing = Fault
Off = Fan unseated from connector or
failed
7
I/O module LED Green = System activity
Amber = Fault
Off = Enclosure is powered off.
8
7-segment display* 1 = SES overall warning
2 = Temperature sensor warning
3 = Cooling fan warning
4 = Power supply warning
5 = Host GSI enabled
6 = I/O PIC upgrade needed
7 = Power supply PIC upgrade needed
8 = CPLD upgrade needed
9 = Standby heartbeat failure
10 = Remote I/O module heartbeat
failure
11 = Enclosure thermal shutdown
imminent
12 = Enclosure thermal shutdown
occurred
13 = Enclosure management bus failure,
false fan failures may occur
14 = Signal integrity errors detected
15 = Power supply PIC communications
error
16 = Unsupported backplane detected
9
UID button/LED (Drawer 1) Blue = UID LED is enabled from the UID
button.
Blue flashing = System is in hard drive
locate mode or an enclosure firmware
update is in progress.
Component identification 10
Item Description Status
Off = UID LED is disabled.
* If the GSI is amber, the system needs service. Activate the associated drawer UID button to view any GSI error codes
on the rear display.
Device bay ID numbers
Hard drive LEDs
Item Description
1
Fault/UID LED (amber/blue)
2
Online LED (green)
Component identification 11
Hard drive LED combinations
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Interpretation
On, off, or flashing
Alternating amber
and blue
The drive has failed, or a predictive failure alert has been received
for this drive; it also has been selected by a management
application.
On, off, or flashing
Steadily blue The drive is operating normally, and it has been selected by a
management application.
On
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
On
Off The drive is online, but it is not currently active.
Flashing regularly
(1 Hz)
Amber, flashing
regularly (1 Hz)
Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is part of an array that is undergoing capacity expansion
or a stripe size migration, but a predictive failure alert has been
received for this drive. To minimize the risk of data loss, do not
replace the drive until the expansion or migration is complete.
Flashing regularly
(1 Hz)
Off Do not remove the drive. Removing a drive may terminate the
current operation and cause data loss.
The drive is rebuilding, or it is part of an array that is undergoing
array expansion, logical drive extension, a stripe size migration,
or RAID migration.
Flashing irregularly
Amber, flashing
regularly (1 Hz)
The drive is active, but a predictive failure alert has been received
for this drive. Replace the drive as soon as possible.
Flashing irregularly
Off The drive is active and it is operating normally.
Off
Steadily amber A critical fault condition has been identified for this drive and the
controller has placed it offline. Replace the drive as soon as
possible.
Off
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive. Replace
the drive as soon as possible.
Off
Off The drive is offline, a spare, or not configured as part of an array.
Operations 12
Operations
Important Safety Information
Before installing this product, read the Important Safety Information document provided.
Firmware update
Before configuring and using the D6000, be sure that the D6000 and all other devices in the SAS fabric are
running the latest compatible versions of firmware.
The D6000 can be installed in a variety of deployments, each of which uses an updating method specific to
the deployment:
If the D6000 is directly connected to a Smart Array controller installed in a rack-mounted server, update
the D6000 firmware using a downloaded Smart Component. For more information about Smart
Components, see Smart Components for ROM Flash.
If the D6000 is connected to a SAS BL Switch as part of a BladeSystem solution, update the D6000
firmware using downloaded firmware image files and the HP 6G Virtual SAS Manager software
embedded in the SAS BL Switch. For more information about updating firmware using the HP 6G Virtual
SAS Manager, see the HP 6G Virtual SAS Manager User Guide, available on the 6Gb SAS BL Switch
website HP website (http://www.hp.com/go/6gbsasbl).
If the D6000 is connected to a SAS BL Switch as part of an HP IBRIX X9000 solution, update the D6000
firmware using the solution's Firmware Management Tool. For more information about these
environments, see the user documents on HP website (http://www.hp.com/go/x9000). (The HP IBRIX
X9000 solution family will be rebranded in late 2012. At that time, product and deliverable names will
be updated to include the new branding.)
The new D6000 firmware activates only after the D6000 is reset from a software tool or manually power
cycled.
Powering up
Observe the following guidelines before powering up the D6000:
Always install all components of the D6000.
Install hard drives in the D6000 so the connected host controllers can identify and configure them at
power up.
Always power up the D6000 first, and then the server.
To power up the D6000:
1. Complete server hardware installation and cabling. For more information, see the server
documentation.
2. Connect the SAS cables and power cords to the D6000.
Operations 13
3.
Press and hold the Power On/Standby button.
Wait and observe the system power LED and system fans. When the D6000 powers up, the system
power LED illuminates solid green and the system fans spin to a high speed, and then spin down to a
low speed.
4. Power up the servers. For more information, see the server documentation.
Power down
Be sure that the partner servers are the first units to be powered down and the last to be powered back up.
Taking this precaution ensures that the system and the OS are shut down in an orderly manner.
IMPORTANT: If installing a hot-plug device, it is not necessary to power down the D6000.
To power down the D6000:
1. Power down the partner servers. See the server documentation.
2. Press and hold the Power On/Standby button for approximately 4 seconds. This action powers down
both hard drive drawers.
Setup 14
Setup
Space and airflow requirements
To allow for servicing and adequate airflow, observe the following space and airflow requirements when
deciding where to install a rack:
Leave a minimum clearance of 63.5 cm (25.0 in) in front of the rack.
Leave a minimum clearance of 76.2 cm (30.0 in) behind the rack.
Leave a minimum clearance of 121.9 cm (48.0 in) from the back of the rack to the back of another rack
or row of racks.
The HP D6000 draws in cool air through the front door, and then expels warm air through the rear door.
Therefore, the front and rear rack doors must be ventilated adequately to enable ambient room air to enter
the cabinet, and the rear door must be ventilated adequately to enable the warm air to escape from the
cabinet.
CAUTION: To prevent improper cooling and damage to the equipment, do not block the
ventilation openings.
When a vertical space in the rack is not populated by a server or rack component, the gaps between the
components cause changes in airflow through the rack and across the servers. Cover all gaps with blanking
panels to maintain proper airflow.
CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in improper cooling that can
lead to thermal damage.
The HP Rack 10000 series rack provides proper server cooling from flow-through perforations in the front
and rear doors that provide a 64-percent open area for ventilation.
CAUTION: HP has not tested or validated the D6000 with third-party racks. If a third-party rack
is used, observe the following additional requirements to ensure adequate airflow and to prevent
damage to the equipment:
Front and rear doorsIf the 42U rack includes closing front and rear doors, you must allow at
least 5,350 sq cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate
airflow (equivalent to the required 64-percent open area for ventilation).
SideThe clearance between the installed rack component and the side panels of the rack
must be a minimum of 7 cm (2.75 in).
Temperature requirements
To ensure continued safe and reliable equipment operation, install or position the D6000 in a well-ventilated,
climate-controlled environment.
The maximum TMRA for most storage products is 35°C (95°F). The temperature in the cold aisle where the
rack is located must not exceed 35°C (95°F). The D6000 reports an over-temperature condition and
Setup 15
performs an emergency shutdown of the hard drive bays within a drawer if the temperature exceeds this limit
for greater than 3 minutes. To recover the system, AC power cycle the D6000.
CAUTION: To reduce the risk of damage to the equipment when installing third-party options:
Do not permit optional equipment to impede airflow around the D6000 or to increase the
internal rack temperature beyond the maximum allowable limits.
Do not exceed the manufacturer’s TMRA.
Power requirements
Installation of this equipment must comply with local and regional electrical regulations governing the
installation of IT equipment by licensed electricians. This equipment is designed to operate in installations
covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992 (code for Protection of
Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the
product rating label or the user documentation supplied with that option.
WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do not
overload the AC supply branch circuit that provides power to the rack. Consult the electrical
authority having jurisdiction over wiring and installation requirements of your facility.
CAUTION: Protect the D6000 from power fluctuations and temporary interruptions with a
regulating UPS. This device protects the hardware from damage caused by power surges and
voltage spikes and keeps the D6000 in operation during a power failure.
When installing more than one D6000, you may need to use additional power distribution devices to safely
provide power to all devices. Observe the following guidelines:
Balance the D6000 power load between available AC supply branch circuits.
Do not allow the overall system AC current load to exceed 80 percent of the branch circuit AC current
rating.
Do not use common power outlet strips for this equipment.
Provide a separate electrical circuit for each power supply in the D6000.
Electrical grounding requirements
The D6000 must be grounded properly for proper operation and safety. In the United States, you must install
the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as
any local and regional building codes. In Canada, you must install the equipment in accordance with
Canadian Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, you must
install the equipment in accordance with any regional or national electrical wiring codes, such as the
International Electrotechnical Commission (IEC) Code 364, parts 1 through 7. Furthermore, you must be sure
that all power distribution devices used in the installation, such as branch wiring and receptacles, are listed
or certified grounding-type devices.
Because of the high ground-leakage currents associated with multiple D6000 connected to the same power
source, HP recommends the use of a power distribution unit (PDU) that is either permanently wired to the
building’s branch circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA
locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using
common power outlet strips for the D6000 is not recommended.
Setup 16
Rack warnings
WARNING: To reduce the risk of personal injury or damage to the equipment, be sure that:
The leveling jacks are extended to the floor.
The full weight of the rack rests on the leveling jacks.
The stabilizing feet are attached to the rack if it is a single-rack installation.
The racks are coupled together in multiple-rack installations.
Only one component is extended at a time. A rack may become unstable if more than one
component is extended for any reason.
WARNING: To reduce the risk of personal injury or equipment damage when unloading a rack:
At least two people are needed to safely unload the rack from the pallet. An empty 42U rack
can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft) tall, and might
become unstable when being moved on its casters.
Never stand in front of the rack when it is rolling down the ramp from the pallet. Always handle
the rack from both sides.
Third-party racks
HP has not tested or validated the D6000 with any third-party racks. Before installing the D6000 in a
third-party rack, be sure to properly scope the limitations of the rack.
Site planning considerations
Customer facility managers and system administrators must discuss site planning, preparation, and system
installation before system delivery. A common understanding of environmental requirements and how the
systems will be delivered, configured, installed, and maintained helps to create a suitable data center and
aids the successful installation of the servers and related equipment.
It is important to plan the facility as a whole, not design based on calculations of individual system or rack
level requirements. Too many interdependencies in a modern data center make such simple calculations
unreliable. Designs and plans must be made for the data center as a whole, including all of its equipment,
with the realization that making one change in the data center environment can affect many other physical,
mechanical, and environmental aspects of the facility.
Take into account the requirements of third-party equipment and support equipment in the room. Dense
computing locations might have high power and cooling demands that could affect power and
environmental constraints. Be aware of rack positioning and airflow patterns. Ensure that the raised floor
space, cooling equipment, power supply equipment and generators, and other support equipment meet the
demands of all the servers and other mission-critical equipment.
Installing the enclosure
WARNING: The D6000 with no drives installed weighs 72.58 kg (160.00 lb). With all drives
and components installed, the enclosure can weigh up to 145.15 kg (320 lb). Before configuring
your rack solution, be sure to check the manufacturer weight limits and specifications. Failure to
do so can result in physical injury or damage to the equipment and the facility.
Setup 17
CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack.
Install the heaviest item first, and continue to populate the rack from the bottom to the top.
CAUTION: HP has not tested or validated the D6000 with any third-party racks. Before installing
the D6000 in a third-party rack, be sure to properly scope the limitations of the rack and consider
the following:
You must fully understand the static and dynamic load carrying capacity of the rack and be
sure that it can accommodate the weight of the D6000.
You must install a 1U tray beneath the D6000 to ensure proper support.
Be sure sufficient clearance exists for cabling, installation and removal of the enclosure,
actuation of the rack doors, and full articulation of the drive drawers.
IMPORTANT: Some racks other than the HP Rack 10000 Series rack do not allow full access to
hard drive bays 2935 in hard drive drawer 2.
The rack rails are marked for easy identification. The left rack rail is marked "L" and the right rack rail is
marked "R."
To install the rack rails:
1. Begin with the left rack rail. Align the end of the rail with the rear rack column.
2. Slide the rack rail closed until the end of the rail is locked in place, wrapping behind the rear rack
column.
3. Slide the front end of the rail to the rack front column. When fully seated, the rack rail will lock into
place.
4. Repeat the procedure for the right rack rail.
Setup 18
WARNING: The D6000 is very heavy. To reduce the risk of personal injury or damage to the
equipment:
Observe local occupational health and safety requirements and guidelines for manual
material handling.
Remove all installed D6000 components from their D6000s before installing or moving the
D6000s.
Use caution and get help to lift and stabilize D6000s during installation or removal, especially
when the D6000 is not fastened to the rack.
WARNING: Always use at least two people to lift an enclosure into the rack. If the enclosure is
being loaded into the rack above chest level, a third person must assist with aligning the enclosure
with the rails while the other two people support the weight of the enclosure.
5. Install the D6000, making sure to tighten the thumbscrews to secure the D6000 to the rack.
The installation is complete.
Installing the hard drives
A D6000 supports up to 35 hard drives per storage drawer. For weight-distribution purposes and
best-possible cooling, populate hard drive bays from the rear to the front, starting with the highest device bay
ID number ("Device bay ID numbers" on page 10). To properly distribute air flow and cool the installed
drives, make sure that all drive bays are populated with a drive or a drive blank.
Before installing the drives, confirm that they are supported for use in the D6000. For more information, see
the QuickSpecs on the HP website (http://www.hp.com/go/d6000/quickspecs).
When adding hard drives to the hard drive drawer, observe the following general guidelines:
Verify that the drives are fully seated before closing the drawer.
The drawer is fully closed when the fans slow down to their normal speed.
The drawer should be closed with the handle in the released position.
Hard drives are sensitive to excess vibration. Use care when opening and closing the drawer.
Setup 19
A RAID 1 mirror requires an even number of hard drives.
Drives that will be configured within an array should be the same capacity to provide the greatest
storage space efficiency.
NOTE: ACU does not support mixing SAS and SATA drives in the same logical volume.
To install the drives:
1. Be sure all I/O bays contain either an I/O module or an I/O blank. The hard drive drawer does not
open if I/O bays are empty.
2. Be sure the I/O modules or I/O blanks are fully seated and their handles are in the locked position. The
hard drive drawer does not open if I/O modules or I/O blanks are not fully seated with their handles
in the locked position.
WARNING: TIP HAZARD! To reduce the risk of personal injury or damage to the equipment, do
not extend the hard drive drawers beyond the supporting surface when the unit is not installed in
a rack.
WARNING: To reduce the risk of personal injury or damage to the equipment, ensure that only
one hard drive drawer is extended at a time.
3. Extend the hard drive drawer.
WARNING: Pinch hazardKeep hands out of front and rear of chassis when closing hard drive
drawers.
CAUTION: To prevent improper cooling and thermal damage, do not operate the D6000 for an
extended period of time with the drawer open.
CAUTION: To prevent improper cooling and thermal damage, do not operate the D6000 unless
all bays are populated with either a component or a blank.
Setup 20
4.
Remove the hard drive blank.
5. Prepare the hard drive.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53

HP D6000 User manual

Category
Disk arrays
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI