  • Hello! I am an AI chatbot trained to assist you with the Robertshaw Bi-Metal Gas Valves User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
INSTALLATION DATA
BI-METAL GAS VALVES
Customer Service Telephone 1.800.304.6563
Customer Service Facsimile 1.800.426.0804
Robertshaw®, Ranco®, Paragon® and Uni-Line® are
trademarks of Robertshaw, its subsidiaries and/or
affiliated companies. All other brands mentioned
may be the trademarks of their respective owners.
For Technical Service
Telephone 1.800.445.8299
Facsimile 1.630.260.7294
www.uni-line.com
www.robertshaw.com
©2014 Robertshaw
10/14 –1-960 RevB
Robertshaw® gas valves come in single and dual 115V models with or
without pilot take-o or in 3 volt versions for use with a silicon carbide
ignitor. Make sure your replacement valve has the correct warning label
for the range to be serviced.
CAUTION
THIS VALVE SHOULD BE REPLACED BY A QUALIFIED SERVICE
TECHNICIAN. IMPROPER INSTALLATION CAN PRESENT A
HAZARD.
CAUTION
LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN
SERVICING VALVES. WIRING ERRORS CAN CAUSE IMPROPER
AND DANGEROUS OPERATION.
WARNING:
DO NOT APPLY 115 VOLTS TO ANY VALVE USING A SILICON
CARBIDE IGNITOR AS IT WILL BURN THE WINDINGS OUT. IF
TEST SHOWS THE VALVE IS GOOD, CHECK FOR OTHER
REASONS FOR THE FAILURE.
The operang ambient temperature range for this valve is 32°F - 300°F.
This valve is cered for use with natural, LP manufactured, and
mixed gases.
TEST:
1. Turn o gas and disconnect electrical power.
2. To test valve, disconnect wires from valve terminals and test for
electrical connuity using a volt/ohm meter.
3. Remove old control. Note: When removing or replacing valve,
support valve inlet ng with a wrench.
4. Inspect electric wires for worn insulaon, breaks, etc., and replace
with original equipment wires, if necessary.
5. Make sure hood size on replacement valve is idencal to original
valve. DO NOT REMOVE OR REPLACE THE HOOD AND/OR PIN.
6. Extreme care must be taken not to let any foreign material, dirt,
burrs, etc., fall into hood outlet or valve inlet. This could present
a hazard.
7. For LP gas installaon, the hood should be screwed down against
the hood pin. For natural gas installaon, the hood should be
backed o two to three turns from the hood pin.
8. Replace the new control exactly as originally installed. Make sure all
gas connecons are ght and that the wires are properly aached.
9. Turn on gas and check for leaks using a diluted soap soluon applied
over all ngs. Watch for bubbles which would indicate a leak.
Aer test, rinse o soap soluon with water as soluon might cause
corrosion. Make sure electrical connecons are dry.
10. Connect electric power and test for operaon:
a. Turn on oven.
b. Check for ignion of burner.
c. If burner does not ignite within 140 seconds turn gas o and
reevaluate system for other problem.
Single Valve Dual Valve
115 Volt Silicon Carbide Igniter Silicon Carbide Igniter
ALTERNATE LABEL ALTERNATE LABEL ALTERNATE LABEL
/