Service XXL
Congratulations on choosing the quality and precision of METTLER
TOLEDO. Proper use according to these instructions and regular
calibration and maintenance by our factory-trained service team
ensure dependable and accurate operation, protecting your investment.
Contact us about a ServiceXXL agreement tailored to your needs and
budget.
We invite you to register your product at
www.mt.com/productregistration
so we can contact you about enhancements, updates and important
notications concerning your METTLER TOLEDO contact.
03/10Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
3
03/10
Contents
English
1 Introduction ...............................................................................5
2 Putting into operation .................................................................9
3 Basic operation ........................................................................11
4 Factor weighing .......................................................................13
5 Formula weighing ....................................................................14
6 Scale check .............................................................................19
7 Master Mode ............................................................................20
8 Error messages ........................................................................23
9 Technical data .........................................................................24
Deutsch
1 Einführung ...............................................................................26
2 Inbetriebnahme ........................................................................31
3 Grundfunktionen.......................................................................33
4 Faktorwägung ..........................................................................35
5 Rezepturwägung ......................................................................36
6 Waagentest .............................................................................41
7 Mastermodus ...........................................................................42
8 Fehlermeldungen ......................................................................45
9 Technische Daten .....................................................................46
Français
1 Introduction .............................................................................48
2 Mise en service ........................................................................53
3 Fonctionnement de base ...........................................................55
4 Pesage avec facteur .................................................................57
5 Formulation .............................................................................58
6 Contrôle de la balance ..............................................................63
7 Master Mode ............................................................................64
8 Messages d'erreur ....................................................................67
9 Caractéristiques techniques .......................................................68
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
5
03/10
1 Introduction
1.1 Safety and environment
1.1.1 General
Product safety is very important for METTLER TOLEDO.
Non-observance of the following instructions can lead to damage to
the weighing terminal and/or injuries.
Read this manual carefully before operating or servicing the
scale.
Store these instructions for future use.
Strictly observe these instructions.
Only permit qualied personnel to make checks, tests and adjust-
ments to be carried out with power on. Failing to observe these
precautions can result in bodily harm.
Always disconnect the scale from the power supply before install-
ing, servicing, cleaning or performing maintenance.
Check the cable of the AC adapter/power supply unit regularly. If
the cable is damaged the scale must not be used.
Treat the scale carefully, it is a precision instrument. Knocks to
the weighing pan or overloading it excessively damage the scale.
Only use recommended accessories and peripherals.
Do not open the scale. The warranty is void if this stipulation is
ignored. The scale may only be opened by authorized persons.
1.1.2 BBA242
Do not use BBA242 in hazardous areas where there are explosive
mixtures of gases, vapors or dusts.
Only use the supplied AC adapter to connect the scale to the
power supply
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Introduction
6
03/10
1.1.3 BBA242x
In hazardous areas of zone 1 resp. Class 1, Division 1, only use
BBA242x.
Only use the METTLER TOLEDO PANDA-EX1P certied power sup-
ply unit to connect the BBA242x to the power supply.
Strictly observe the separate Installation Instructions of the
PANDA-EX1P power supply unit.
It is only permitted to use a protective cover in hazardous areas if
the cover is made from statically non-hazardous material.
1.1.4 BBA242xx
In hazardous areas of zone 2, only use BBA242xx.
Only use the METTLER TOLEDO HK-CP07-A12 certied AC adapt-
er to connect the BBA242xx to the power supply.
The scale shall be installed in such a way that there is a low risk
of mechanical danger for the plastic parts of the enclosure and
the display window.
The plastic surfaces must not be wiped clean or rubbed in a haz-
ardous area to avoid the ignition danger caused by electrostatic
charges.
Indoor use only. Not allowed to be exposed to sunlight, or other
source of UV radiation.
The scale may only be used in a dust free, dry environment (IP4X
by location).
1.1.5 Disposal
In conformance with the European Directive 2002/96/EC on Waste
Electrical and Electronic Equipment (WEEE), this device must not be
disposed of in domestic waste. This also applies to countries outside
the EU as per their specic regulations.
Please dispose of this product in accordance with local regula-
tions at the collecting points specied for electrical and electronic
equipment.
If you have any questions, please contact the responsible authority or
the distributor from which you purchased this device.
Should this device be passed on to other parties (for private or profes-
sional use), the content of this regulation must also be related.
Thank you for your contribution to environmental protection.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
7
03/10
1.2 Description
1.2.1 Features
With the paint scale you can mix components in predened propor-
tions by weighing.
The paint scale offers three operating modes:
Simple weighing
Factor weighing to modify a given formula
Formula weighing controlled by a computer via the built-in
RS232 interface
The paint scale offers two different correction modes to compensate
errors made when weighing the components.
1.2.2 Overview
2
1 Rubber feet
2 Weighing pan
3 Display
4 Function keys
5 Model designation with details of Max. (maximum capacity) and
d (resolution)
6 AC adapter
7 Power supply unit PANDA-EX1P
8 Connecting socket for AC adapter/power supply unit
9 Grounding screw
10 RS232 interface
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Introduction
8
03/10
1.2.3 Keys
Key Press briey Press and hold
Tare the scale Switch the scale on and off
Enter conversion
factor for weighing
a smaller or larger
quantity of a given
formula
Reset the conversion fac-
tor to 1, i.e. to weighing
without factor
Enter Master Mode
Select weighing
mode or conrm
Cancel or return to
previous menu
Up selection
Down selection
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
9
03/10
2 Putting into operation
2.1 Assembling
1. Remove display module and scale base from the package and
place it on a solid, at surface.
2. Mount the display module to the scale base using the included
M6x20 screw.
2.2 Setting up
For accurate weighing results, care must be taken to select the optimal
location for the scale!
Place the scale on a stable surface which is free of vibrations and
as horizontal as possible.
Avoid excessively uctuating temperatures and direct sunlight.
Ensure correct environmental conditions.
Avoid drafts (for example, from fans or air conditioning).
Never use a hammer to close paint cans on the weighing pan.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Putting into operation
10
03/10
2.3 Connecting to the power supply
2.3.1 BBA242x and BBA242xx for hazardous zones
In hazardous zones only certied power supply units must be used.
BBA242x PANDA-EX1P certied power supply unit
BBA242xx HK-CP07-A12 certied AC adapter
Strictly observe and follow the instructions in the separate instal-
lation instructions for the PANDA-EX1P certied power supply unit
or HK-CP07-A12 certied AC adapter.
2.3.2 BBA242
For normal environment use the AC adapter included.
CAUTION!
Damages to the device!
Make sure that the voltage printed on the AC adapter is the same
as the local power supply voltage.
1
2
1. Connect the AC adapter to the socket of the scale.
2. Insert the plug of the AC adapter into the power supply outlet.
When the scale has been connected, it performs a display test and
then the sofware version is displayed briey.
As soon as the weight display appears, the scale is ready for op-
eration.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
11
03/10
3 Basic operation
3.1 Switching on and off
Switching on
Press and hold until the display lights go on.
The scale performs a display test.
As soon as the weight display appears, the scale is ready for
operation.
Switching off
Press and hold until the display lights go out.
3.2 Simple weighing
1. Place the empty container on the scale.
2. Press briey to tare the container.
The zero display appears.
3. Fill in the desired quantity of the substance to be weighed.
4. Wait until the stability detector (ring symbol in the display) goes
out and then read the weighing result.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Basic operation
12
03/10
3.3 Locking the keyboard
You can lock the keyboard so that only the key is active.
Locking
Press and simultaneously for at least 2 seconds.
The message "keys locked" appears briey.
Unlocking
Press and simultaneously for at least 2 seconds.
The message "keys unlocked" appears briey.
The message "keys locked" also appears if a key is pressed while the
keyboard is locked.
3.4 Cleaning
DANGER!
Electric shock hazard due to ingress of moisture!
Before cleaning the paint scale, disconnect the unit from the
power supply.
Further notes on cleaning
Use a damp cloth.
Do not use any acids, alkalis or strong solvents.
Do not clean the paint scale using a high-pressure cleaning unit
or under running water.
If the scale is heavily soiled, remove the protective cover (if pres-
ent) from the weighing pan and clean these parts separately.
Follow all the relevant instructions regarding cleaning intervals
and permissible cleaning agents.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
13
03/10
4 Factor weighing
To weigh a larger or smaller quantity of a given formula, a factor from
0.20 to 5.00 can be selected.
4.1 Selecting factor
1. Press to activate the factor weighing function.
The factor used for the last factor weighing (e.g. 0.5) appears in
the lower left corner of the display.
2. Press briey several times until the desired factor (e.g.0.2)
is displayed.
4.1.1 Weighing with a factor
Weigh the component as described in simple weighing.
For the weight displayed see the examples below.
Example 1
Weight according to formula 1000 g
For half the quantity Factor = 0.50
Display 1000 g
Current weight 500 g
Example 2
Weight according to formula 1000 g
For triple quantity Factor = 3.00
Display 1000 g
Current weight 3000 g
4.2 Deactivating factor weighing
Press and hold until the factor display disappears.
The factor is reset to 1.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Formula weighing
14
03/10
5 Formula weighing
5.1 Entering formula mode
1. In simple weighing mode press to enter the mode selection
menu.
2. Move the cursor to "Formula Mode" using and press to
enter the formula mode.
With a new scale no formulas are displayed. Formulas must be down-
loaded rst.
If formulas are already downloaded to the scale you can proceed with
the formula process, see page 16.
5.2 Download formulas
Prerequisite
The interface settings of the scale and the computer must be the same.
For the interface settings of the scale see page 22.
5.2.1 Remote download
If the scale is in simple weighing mode the PC can send formulas and
read mixing protocols.
During transmission the keys are locked and the message "Download
Formula Data" is displayed.
After transmission the keys are automatically unlocked and the mes-
sage "New Jobs" is displayed.
Make sure to leave formula mode when you have nished your
jobs, so that the remote download of new formulas is enabled.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
15
03/10
5.2.2 Download manually
With "Formula Management" highlighted, press to enter the
formula management menu.
The rst menu of formula management "Communication" is high-
lighted.
1. Select Communication and press .
The scale automatically communicates with the PC.
2. Start the formula download on the PC.
All keys on the scale are blocked during the download procedure.
After nishing the download, the new formulas are displayed.
The scale can manage up to 20 formulas.
5.3 Setting recalculation mode
The scale provides two methods of recalculation when an error in
pouring has occurred:
ADV ABS IMM
Correction immediately after an incorrectly weighed component
ADV ABS END
Correction at the end of the formula weighing operation
1. Select Recalculation using and press .
2. Select the desired correction mode using or and con-
rm with .
or
Press to return to the previous menu.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Formula weighing
16
03/10
5.4 Formula process
After formulas have been downloaded to the scale from a PC, the
display shows the formula names and statuses.
Formula 1 pending – this formula can be selected
Formula 1 completed – this formula cannot be selected again
Formula 1 aborted or discarded this formula cannot be selected
again
5.4.1 Formula weighing
1. Select a pending formula using or and press to
start formula weighing.
The formula name is displayed.
If necessary, additional information is displayed, too. This infor-
mation is provided by the PC program.
2. Place the empty container on the scale and press to tare
the container.
The weighing dialog is now displayed.
In the upper left corner the selected recalculation mode is shown,
here ADV END.
The main part of the display shows the weight data and the com-
ponent name.
The weight is shown as negative value, zero corresponds to the
target value.
3. Fill in the component and follow the operator guidance.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
17
03/10
Depending on the weight, one of the following three statuses appears:
r Current weight lower than the minimum tolerance
No keys accessible
2TQEGGFYKVJƂNNKPIKPWPVKNVJGVCTIGVTCPIGKUTGCEJGF
r Current weight within the target range
Press VQ EQPƂTO VJG EQORQPGPV CPF EQPVKPWG YKVJ VJG
next component
r Current weight higher than the maximum tolerance
Press VQEQPƂTOVJGEQORQPGPV
"Recalculation?" is displayed.
By pressing , recalculation is done using the selected recal-
culation mode, here at the end.
By pressing , no recalculation will be carried out.
5.4.2 Finishing the formula
9JGPCNNEQORQPGPVUJCXGDGGPƂNNGFKP,QDEQORNGVGF2TGUU'PVGT
VQƂPKUJKUFKURNC[GF
Press VQƂPKUJVJGHQTOWNCCPFTGVWTPVQVJGHQTOWNCNKUV
The status of the formula is automatically updated.
A completed formula cannot be accessed again.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Formula weighing
18
03/10
5.4.3 Aborting a formula
You can abort a formula at any time. An aborted formula cannot be
accessed again.
1. In formula weighing press to exit and abort the formula.
A safety query is displayed.
2. Press to abort the formula and return to the formula list.
or
Press not to abort the formula and continue formulation.
5.4.4 Deleting a formula
Only pending formulas can be deleted.
1. Select the formula to be deleted using or .
2. Press .
A safety query is displayed.
3. Press to delete the formula and return to the formula list.
or
Press to keep the formula.
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
19
03/10
6 Scale check
The scale check function is a quick way to check whether the scale
operates within acceptable tolerances.
1. In simple weighing mode press to enter the mode selection
menu.
2. Select "Scale Check" using and press to enter the scale
check.
3. When the message "Unload scale" appears, make sure that the
scale is empty and press .
When a weight value is displayed the scale asks for the test
weight.
4. Place the test weight you have received with the scale on the
scale. The test weight must be clean and free from paint or other
residues.
5. Check that the correct test weight is shown on the display and
press to continue.
If the scale operates within the tolerances, the message "Scale is OK"
will be shown.
Press to go back to standard weighing operation.
If the scale operates outside of the tolerances, the message "Scale is
out of tolerance" will be shown.
1. Press to go back to standard weighing operation.
2. Repeat the scale check function by pressing again.
If the scale still operates out of tolerance, contact the supplier of the
scale or the designated support contact.
The test weight and the acceptable tolerances can be adjusted in
the scale conguration menu (see page 22).
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Master Mode
20
03/10
7 Master Mode
In the Master Mode the settings of the scale can be changed and func-
tions can be activated.
7.1 Calling up the Master Mode
1. In weighing mode press .
"Master Mode" is displayed.
2. Press to enter the Master Mode.
The rst menu block of the Master Mode is highlighted.
7.2 Operating the Master Mode
For operating the Master Mode the following keys are used:
Key Master Mode
Scrolling forward
Scrolling back
Moving back to the next higher menu item
Activating menu item
Accepting selected setting
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
21
03/10
7.3 Overview of the Master Mode
Factory settings are printed in bold characters.
Settings Function
Calibrate Calibrate/adjust scale
Language
English
French
Italian
Spanish
German
Select language
Scale
Resolution
0.1
0.05
Unit
g
oz
P
Backlight
On
Off
Automatic
On
Off
Filtering
Low
Middle
High
Process
Dosing
Universal
Reset
Factory Setting
Congure scale settings
Select resolution
Single range: 0 .... 7100 g / 0.1 g
Delta range: 0 ... 999.95 g / 0.05 g;
1000 ... 7100 g / 1.0 g
Select weighing unit
Gram
Ounce
Parts (1P = 1/32 oz)
Switching display backlighting on/off
Display backlighting on
Display backlighting off
Switching automatic memory function on/off
With "Automatic On", the scale keeps zero
and tare values when being switched off and
on.
Memory function on
Memory function off
Select ltering mode
Very stable environment
Normal environment
Unstable environment
Select weighing process
Dosing, e.g. for liquids or powders
For other weighing goods
Reset scale settings to factory settings
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
Master Mode
22
03/10
Settings Function
Interface
Protocol
Xon/Xoff
No
Parity
7 EVEN
7 NO P
8 NO P
7 ODD
Baud
300
...
38400
Auto Mode
AUT.SIR
No
Reset
Factory Setting
Congure serial interface
Select transmission protocol
Xon/Xoff protocol
No protocol
Select data bits and parity
7 bits, parity even
7 bits, no parity
8 bits, no parity
7 bits, parity odd
Select baud rate
300 baud
600, 1200, 2400, 4800, 9600,
19200baud
38400 baud
Automatic data transmission
Continuous data transmisssion
Data transmission on request
Reset interface settings to factory settings
Scale Check
Load
0.2 kg
...
7 kg
Tolerance
1 %
2 %
Reset
Factory Setting
Congure scale check settings
Select load for checking the scale
0.2 kg
0.5 kg, 1 kg, 2 kg, 3 kg, 4 kg, 5 kg, 6 kg
7 kg
Select tolerance for checking the scale
1 %
2 %
Reset scale check settings to factory settings
Order number 72227280 METTLER TOLEDO User Manual BBA242 / BBA242x / BBA242xx
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116

Mettler Toledo BBA242x User manual

Category
Kitchen scales
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI