  • Hello! I've reviewed the user manual for the tempmate C1 Temperature Data Logger and I'm ready to assist you with any questions you may have about its features, setup, operation, or technical specifications. It's designed for monitoring temperature during transport with features like a LCD display, USB connection, configurable alarms, and a long battery life of up to 90 days.
  • What is the intended use of the tempmate C1?
    How do I start the data logger manually?
    How do I stop the data logger manually?
    Can I reconfigure the device during recording?
empower your supply chain.
V1.0-08/2023-EN · Technical Changes and Errors excepted 3
1. Intended Use ...........................................................................................................................................................................................3
2. Device Description ................................................................................................................................................................................4
3. Display ...................................................................................................................................................................................................... 5
4. Operation and Use ................................................................................................................................................................................6
 Conguration................................................................................................................................................................................6
 Startlogger..................................................................................................................................................................................6
Set mark .................. .....................................................................................................................................................................7
 Temporaryevaluation...............................................................................................................................................................8
 Stoplogger....................................................................................................................................................................................8
 Evaluation......................................................................................................................................................................................8
5. Important Notes ....................................................................................................................................................................................9
6.MainTechnicalSpecicationstempmate.®-C1.....................................................................................................................10
7. Contact Information...........................................................................................................................................................................12
Contents
1. Intended Use
Thetempmate.®-C1isasingle-usetemperaturedata
loggerspecicallydesignedtomonitortemperaturedu-
ringtransportationofproductsthatmustbestoredat
extremelylowtemperatures.Anyuseoroperationthat
requiresspecicrequirementsandstandardsnotspe-
cicallymentionedinthedatasheetmustbevalidated
andtestedatthecustomer‘sownresponsibility.
empower your supply chain.
V1.0-08/2023-EN · Technical Changes and Errors excepted 5
1RecordingStatus
2 Mark
3 Battery Level
4AlarmLevel
5 Password Protection
6MeasurementValue
7TemperatureUnit,TimeUnit
8Max.Value,Min.Value,AverageValue
9AlarmStatus
10 Start Delay
11 Reuse–canbeusedforseveralcampaigns
12StopButtonInvalid
2. Device Description 3. Display
USB Port
StartButton
StopButton
- Toscrollthroughthemenu,pressthegreenstartbuttonseveraltimesinquicksuccession.
- Thedisplaychangesfromthecurrenttemperaturedisplayrsttothemaximumrecorded
 temperaturevalue,thentotheminimumandnallytotheaveragevalueofthecurrentrecording.
- Pressingthebuttonagaintakesyoubacktothecurrenttemperaturedisplay.
- Todisplaytheremainingusagetimeofthedevice,presstheredstopbutton.Theeffective
 recordingtimedependsontheselectedmeasuringinterval.
Important:Thetotalrunningtimeof90dayswith24hourseachwillbedeductedperhourafterthestart
Menunavigation
empower your supply chain.
V1.0-08/2023-EN · Technical Changes and Errors excepted 7
4. Operation and Use
STEP1Conguration*optional
Thisstepisonlynecessaryifyouwanttoadjustthepre-installedcongurationtoyourapplication.
- Downloadthefreetempbase.-Cryosoftware.
https://www.tempmate.com/de/download/
- Installthetempbase.-CryosoftwareonyourPC.
- RemovethecapandconnecttheunbootedloggertoyourPC.
- Openthetempbase.-Cryosoftware.Thecongurationscreenisdisplayeddirectly.
- Makethedesiredsettingsandsavethemviathemenuitem„SaveParameter“(1) ontoyourdevice.
- RemovetheloggerfromyourPCandreplacethecapsecurely.
STEP2Startlogger(manually)
- Pressandholdthegreenstartbuttonfor5seconds.
- Asuccessfulstartisindicatedby
bEGn
onyourdevicedisplay.
Important:Ifadifferentsignalornosignalappears,donotusetheloggerandcontactoursupportvia
suppor[email protected].Thedevicedisplayisdisableduntilthedevicehasbeensuccessfullystarted.
Alternativestartmodes
Startviasoftware(optional)
o Thissettingcanbemadeinthetempbase.-Cryosoftware.
  (seeSTEP1)
o ThestartistriggeredautomaticallyassoonasthedeviceisdisconnectedfromthePC.
Important:Amanualstartisnotpossiblewiththisconguration.
Timedstart:(optional)
o Thissettingcanbemadeinthetempbase.-Cryosoftware.
  (seeSTEP1)
o Thedevicewillstartaccordingtothetimesetinthecongurationsoftware.
Important:Amanualstartisnotpossibleinthisconguration.
Important:Whensettingastartdelay,thedisplayshowsacountdownoftheselectedtimeperiod.
STEP 3 Set mark
- Pressthegreenstartbuttontwiceinquicksuccession.
- Assoonasthedevicerecordsthemarking,thesymbolappears..
- Oncethesymboldisappears,themarkingprocessiscompleted.
Important:Onlyonemarkispossiblepermeasuringinterval.
*Example
empower your supply chain.
V1.0-08/2023-EN · Technical Changes and Errors excepted 9
STEP6Evaluation
- ConnectthestoppedloggertoyourPC.
- Thedisplaywillshow
PdF
and/or
CSu
toindicatethattherespectivereportsarebeinggenerated.
- Oncethereportisgenerated,thedisplaywillshow
USb
.
- TheloggercannowbedisconnectedfromthePC.
Important:Alwaysmakesurethatthisstepisperformedbeforerestartingthedevice.Ifthedeviceisrestarted,
allolddatawillbeoverwritten.
STEP4TemporaryEvaluation
- ConnectyourstartedorpauseddevicetoyourPC.
- Atemporaryreportwillbegeneratedautomatically.
- SaveyourreportandremovetheloggerfromyourPCagain.
Important: IfyouconnecttheloggertoyourPCinthestartedmode,therecordingwillcontinuealsointhis
moment.Inordertobeabletoassignanyuctuationsinyourmeasurementresults,weadviseyoutoseta
markbeforeandafterthetemporaryreadout(seeSTEP3).
STEP 5 StopLogger(manual)
- Pressandholdtheredstopbuttonfor5seconds.
- Thedisplayswitchesoffafterasuccessfulstop.
Important: Inthestoppedstate,ashortpressofanykeyissucienttoviewthemax.,min.andaveragevalue
ofthelastrecording.
Important:Thedevicestopsautomaticallywhenthememoryisfull.
Alternativestopmodes
StopbySoftware(optional)
o Openthetempbase.-Cryosoftwareandconnectyourunstoppedtempmate.®-C1toyourPC.
 (seeSTEP1)
o Selectthe„Stoprecording“menuitemtostopthedevice.
5. Important Notes
- Iftheiconisdisplayedonthescreen,theloggerneedstoberecongured
- Whenisdisplayedonthescreen,itmeansthatthebatteryleveloftheloggeristoolowtorecord
 formorethananother10days.
- Iftheiconisdisplayed,thelogger‘sbatteryistoolowtorecord.
- Thecongurationofyourdevicecannotbechangedduringrecording.
- Alwaysdisposeofbatteriesaccordingtoyourcountry‘sregulations.
- Donotplacethedeviceincorrosiveliquidsorexposeittodirectheat.
empower your supply chain.
V1.0-08/2023-EN · Technical Changes and Errors excepted 11
MainTechnicalSpecicationstempmate.®-C1
Model DryIce/LowTemperatureDataLogger
PartNumber TC1-000
Usage Single-Use/MultiStart/Stopwithin90dayspossible
TemperatureRange -90°Cto+70°C
Accuracy ±0.5°C(-30°Cto+70°C)±1.0°C(others)
Resolution 0.1°C
Memory Capacity 20.000ReadingsusingPDF&CSV(default)
35.000ReadingsusingPDFonly(optional)
Connection USB
Indication LCD
Battery 3.6VLithiumBattery
Runtime Max.90days
Dimensions 96mm(L)*44mm(W)*15mm(H)
IP Protection IP65
Mark Max. 9 points
Alarm Max. 6 points
LoggingInterval 1minute-24hours
Start Delay 1minute-24hours
ReportFormat PDF/CSV
Software Freetempbase-CryoSoftwareforWindowssystems
Certications CE,RoHs,EN12830,RTC-DO160
Shelf-Life 2 Years
empower your supply chain.
V1.0-08/2023-EN · Technical Changes and Errors excepted 13
Doyouhaveanyquestions?Pleasecontactus-our
experiencedteamwillbehappytosupportyou.
+49713163540
Contact Information
tempmateGmbH
Wannenäckerstr. 41
74078Heilbronn,Germany
Tel.+49-7131-6354-0
www.tempmate.com
/