Loctite
®
Zeta
®
7500
Portable UV
Spot Lamp
980127
Contents
Page No.
1 Please observe the following . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Emphasized Sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 Items Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.3 For Your Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.1 Field of Application (Intended Usage). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
2.2 Operating Elements and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.1 Utility and Space Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.2 Installing the UV Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3.3 Replacing the UV Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5 Care and Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.1 Glass and Reflector. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.2 Lamps and Sockets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
7 Recommended Spare Parts and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 4
8 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1
1 Please observe the following
1.1 Emphasized Sections
WARNING!
Refers to safety regulations and required safety measures that protect the operator or other
persons from injury or danger to life.
Caution!
Emphasizes what must be done or avoided so that the unit or other property is not damaged.
Notice:
Gives recommendations for better handling of the unit during operation or adjustment as well as
for service activities.
1.2 Items Supplied
Carefully remove the system from its shipping carton and inspect it for any signs of damage. Any
damage should be reported immediately to the carrier. Refer to the list of supplied parts below
and compare to the contents. Report any missing parts promptly to the Loctite customer service
department at 1-800-LOCTITE or 1-800-562-8483.
(1) Portable Spot Lamp Assembly
(1) UV Safety Glasses
(1) Operator Manual
1.3 For Your Safety
IMPORTANT! DO NOT OPERATE THE UNIT BEFORE READING THIS SECTION
The Loctite
®
Zeta
®
7500 Portable UV Spot Lamp is a source of long wavelength ultraviolet light
used to cure light sensitive products. The following guidelines should be followed at all times to
ensure protection from the ultraviolet light.
1. UV protective glasses with side shields should be worn when working with and around the
lamp system. Glasses should meet ANSI Z87.1 certification.
2. Potentially exposed skin should be covered. Long sleeves and protective gloves should be
worn when placing and removing parts from under the lamp.
3. Never look directly at the output from the lamp or directly into the lamp/reflector.
4. Removing the glass filter from the lamp housing may speed up the cure of some products,
however, this will also speed injury to eyes and unprotected skin. DO NOT OPERATE THE
LAMP WITH THE FILTER REMOVED.
UV safety is the responsibility of the user, especially when operating the Zeta
®
7500 in a non-
standard configuration. When in doubt about UV safety, consult a Loctite technical specialist at
1-800-LOCTITE OR 1-800-562-8483.
2 Description
2
2.1 Field of Operation
The Loctite
®
Zeta
®
7500 Portable UV Spot Lamp is ideal for low energy “Light Cure” products. The
unit is primarily used for confined bondline applications to cure Lite-Tak
®
Light Cure Adhesives.
NOTE: UV cure rate is dependent on lamp intensity, distance from the light source, depth of
cure needed, or bondline gap and the light transmittance of the substrate through which the
radiation must pass. Loctite recommends that you test all adhesive applications under simulated
or actual end-use conditions to ensure that the adhesive meets or exceeds all required product
specifications. Refer to the Loctite Light Cure Selector Guide or product Technical Data Sheets
for curing specifications and performance.
2.2 Operating Elements and Controls
5" LAMP DIA.
2.94 DIA. LAMP HOUSING
5.88 DIA.
ON/OFF
3.1 Utility and Space Requirements
Electrical: 115 VAC, 5 amps, 60 Hz.
Overall Dimensions: 17.27 inches high x 9.88 inches wide x 5.88 inches deep.
3.2 Installing the UV Bulb
Lamp should be handled only when cool and with clean cotton gloves. Do Not touch the lamp
with bare hands. Oils on your hands will etch the quartz glass, create hot spots, and can reduce
lamp life.
The unit shipped without the UV bulb installed. See instructions below for initial bulb installation.
1. Disconnect the electric power from unit.
2. Remove the three phillips head screws holding the filter assembly to the lamp housing.
3. Remove the filter assembly.
4. Wearing clean cotton gloves, screw the new bulb securely into socket.
5. Replace the filter assembly and screws.
3.3 Replacing the UV Bulb
1. Disconnect the electric power from unit.
2. Allow the lamp to cool.
3. Remove the three phillips head screws holding the filter assembly to the lamp housing.
4. Remove the filter assembly.
5. Wearing clean cotton gloves, remove the old bulb.
6. Screw the new bulb securely into socket.
7. Replace the filter assembly and screws.
3
3 Installation
4 Operation
1. Connect the plug to a 115 volt, 60 Hz. grounded outlet.
2. Move the power switch to the “ON” position. Allow 3 to 5 minutes for the lamp to reach
full intensity.
3. If the lamp will be used intermittently, at frequent intervals, leave the lamp on continuously
rather than turn it on and off. This procedure gives longer bulb life and avoids the lamp
restarting delay.
4. If the lamp is turned off and then back on, it will not restart until the mercury vapor in the bulb
cools. This will take approximately 4 minutes.
5. The lamp head can be positioned on either of the two mounting posts on the power supply or
it can be removed for other mounting or hand held use.
WARNING!
Lamp Housing and Filter will get hot during continuous operation. Take care not to touch these
parts. DO NOT operate the lamp with the filter removed.
4
5 Care and Maintenance
Unplug the Power Cord from Wall Outlet and Disconnect from Unit Before Any
Maintenance is Attempted.
5.1 Glass and Reflector
Clean the glass every two months or as required. Product vapors can condense on the glass
over time, forming a film that can significantly reduce the transmittance of UV light to the parts.
Clean the aluminum reflector every four months or as required.
The reflector is accessed by removing the filter glass. Use isopropyl alcohol to clean both the
reflector and glass.
5.2 Lamps and Sockets
Inspect the lamp sockets when installing a new lamp and replace if corroded. Heat generated by
poor connections can reduce lamp life.
Lamp should be replaced as required (follow instructions in Section 3.2. It is recommended that
the lamp be monitored regularly with a radiometer to insure that the product is being completely
cured. The Loctite
®
Zeta
®
Meter 7010 (part number 98001) can be used to monitor performance.
As an alternative, regular inspection of the cured product may provide an indirect and less
accurate measure of lamp function. If a radiometer is not used to track lamp life, the lamp
should be replaced at least after every 1,000 hours of operation.
6 Troubleshooting
PROBLEM CAUSE SOLUTION
Lamp does not light. Lamp loose in socket. Tighten lamp (instructions above).
Lamp at end of life. Replace per instructions 3.3.
Lamp too hot. Allow lamp to cool off.
Lamp goes out during Lamp at end of life. Replace per instructions 3.3.
operation. Low input voltage. Check power source.
7 Recommeded Spare Parts and Accesssories
Loctite Part No. Description
982033 Spare UV Bulb
97210 UV Safety Glasses
5
8 Warranty
Loctite expressly warrants that all products referred to in this Instruction Manual for item
980127, Zeta
®
7500 Portable UV Spot Lamp (hereafter called “Products”) shall be free from
defects in materials and workmanship. Liability for Loctite shall be limited, as its option, to
replacing those Products which are shown to be defective in either materials or workmanship or
to credit the purchaser the amount of the purchase price thereof (plus freight and insurance
charges paid therefor by the user). The purchaser’s sole and exclusive remedy for breach of
warranty shall be such replacement or credit.
A claim of defect in materials or workmanship in any Products shall be allowed only when it is
submitted in writing within one month after discovery of the defect or after the time the defect
should reasonably have been discovered and in any event, within 12 months after the delivery
of the Products to the purchaser. This warranty does not apply to perishable items, such as
bulbs, fuses, filters, etc. No such claim shall be allowed in respect of products which have been
neglected or improperly stored, transported, handled, installed, connected, operated, used, or
maintained. In the event of unauthorized modification of the Products including, where products,
parts or attachments for use in connection with the Products are available from Loctite, the use
of products, parts or attachments which are not manufactured by Loctite, no claim shall be
allowed.
No Products shall be returned to Loctite for any reason without prior written approval from
Loctite. Products shall be returned freight prepaid, in accordance with instructions from Loctite.
NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED,
MISUSED, NEGLECTED, OR DAMAGED BY ACCIDENT, OR IF THE SYSTEM USED TO
DISPENSE ANY LIQUID MATERIAL OTHER THAN LOCTITE PRODUCTS.
EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, LOCTITE
MAKES NO WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH
RESPECT TO THE PRODUCTS.
ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE,
AND OTHER WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR
TRADEMARK INFRINGEMENT) ARE HEREBY DISCLAIMED BY LOCTITE AND WAIVED
BY THE PURCHASER.
THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR LOCTITE TO
THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF
DEFECTIVE PRODUCTS.
WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE
UNDER APPLICABLE LAWS, LOCTITE EXPRESSLY DISCLAIMS ANY LIABILITY
WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN
CONNECTION WITH THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH,
THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS AND SPECIAL,
INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY NEGLIGENCE FROM
LOCTITE OR OTHERWISE.
Loctite Americas
1001 Trout Brook Crossing
Rocky Hill, CT 06067-3910
Loctite Corporation
One Northfield Plaza, 5600 Crooks Rd.
Suite 105
Troy, Michigan 48098
Loctite Canada Inc.
2225 Meadowpine Blvd.
Mississauga, Ontario L5N 7P2
Loctite Company de México, S.A. de C.V.
Calzada de la Viga s/n, Fracc. Los Laureles
Loc. Tulpetlac, C.P. 55090
Ecatepac de Morelos, Edo. de México
México
Loctite Brazil
Av. Prof. Vernon Krieble, 91
06690-11-Itapevi
São Paulo-Brazil
www.loctite.com
Loctite, Zeta, and Lite-Tak are trademarks of Loctite Corporation, U.S.A. Data in this manual is subject to change without notice.
© Copyright 2001. Loctite Corporation. All rights reserved. P/N980747 Rev. D 01/01
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Loctite Zeta 7500 Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI