Thermo Fisher Scientific LTQ Orbitrap XL Getting Started xiii
Figures
Tune Plus window ................................................................................ 2-2
Spectrum View page .............................................................................. 2-3
Spectrum Display Options dialog box - FT page ................................... 2-4
Graph view page ................................................................................... 2-5
Status view page - All page .................................................................... 2-6
User Status Display Configuration dialog box ....................................... 2-7
Define Scan dialog box .......................................................................... 2-9
Lock Masses dialog box ....................................................................... 2-11
Define Scan dialog box with HCD selected as activation type ............. 2-13
Spectrum Averaging dialog box ........................................................... 2-15
FT Transfer Optics dialog box ............................................................ 2-16
Ion Trap page of the Injection Control dialog box .............................. 2-17
FT page of the Injection Control dialog box ....................................... 2-18
Ion Trap page of the Vacuum dialog box ............................................ 2-19
FT page of the Vacuum dialog box ..................................................... 2-19
FT Temperature Monitor dialog box .................................................. 2-20
Recommended settings in the Define Scan dialog box for an automatic tune
of the ion trap ....................................................................................... 3-9
Ion trap spectrum of the LTQ Orbitrap XL calibration solution, scan
range 120–2000, positive ion polarity mode ......................................... 3-9
Ion trap spectrum of the LTQ Orbitrap XL calibration solution, scan
range 150–2000, negative ion mode ................................................... 3-10
Automatic page of the Calibrate dialog box ......................................... 3-11
Semi-Automatic page of the Calibrate dialog box ................................ 3-12
Semi-Automatic page of the Calibrate dialog box (Advanced Calibration
Features enabled) ................................................................................ 3-14
Check page of the Calibrate dialog box ............................................... 3-15
FT Manual page of the Calibrate dialog box ....................................... 3-18
System evaluation page of the Diagnostics dialog box ............................ 4-2
Result of the FT stability test displayed in the Graph View ................... 4-5
Toggles page of the Diagnostics dialog box ........................................... 4-6
Set device page of the Diagnostics dialog box ...................................... 4-10
Display settings page of the Diagnostics dialog box ............................. 4-12
MS Detector Setup View - MS Detector Setup Page ............................. 5-2
Data Dependent Settings dialog box – Current Segment page .............. 5-3
Charge State page of the Data dependent settings dialog box with Advanced
Features on ............................................................................................ 5-4
Data Dependent Settings dialog box – Current Scan Event page ........... 5-5
Current Scan Event page - Repeat previous scan event with HCD ....... 5-6
Data Dependent Settings dialog box – Scan Widths page ..................... 5-7
Data Dependent Settings dialog box – Activation page ......................... 5-8
Data Dependent Settings dialog box – FT HCD page .......................... 5-9
MS Detector Setup Page - Scan event settings with HCD experiment 5-10