Contents
xLTQ Orbitrap Getting Started Thermo Fisher Scientific
Applicable Calibration Solutions for FT Manual
Calibration..................................................................... 3-9
Calibration and Tuning of the Ion Trap ......................... 3-10
Calibration of the Ion Trap.......................................... 3-10
Tuning the Ion Trap for Positive Ion Mode................. 3-10
Tuning the Ion Trap for Negative Ion Mode ............... 3-12
Automatic Calibration Page ............................................ 3-13
Semi-Automatic Calibration Page ................................... 3-14
Check Calibration Page................................................... 3-16
FT Manual Calibration Page........................................... 3-19
Mass List Group Box ................................................... 3-20
Chapter 4 Performing Diagnostics/Checks............................................ 4-1
System Evaluation Procedures........................................... 4-2
FT Dynamic Range Test................................................ 4-2
FT Energy Dependence Evaluation................................ 4-2
FT High Mass Range Target Compensation .................. 4-3
FT Isolation Test ........................................................... 4-3
FT Noise Test................................................................ 4-3
FT Preamp Evaluation ................................................... 4-3
FT Pulser Evaluation...................................................... 4-4
FT Sensitivity Test......................................................... 4-4
FT Stability Test ............................................................ 4-4
FT Temperature Control Evaluation.............................. 4-5
FT Temperature Monitor .............................................. 4-5
Toggles ............................................................................. 4-6
FT Analyzer Ion Gauge.................................................. 4-7
FT Analyzer Temperature Control................................. 4-7
FT Apodization.............................................................. 4-7
FT Include Transients.................................................... 4-7
FT Manual Calibration for Single Range ....................... 4-7
FT Profile Mode ............................................................ 4-8
FT SIM and MSn Injection Waveforms......................... 4-8
FT Storage Evaluation Mode ......................................... 4-8
FT Storage Multipole RF............................................... 4-8
FT Transfer Multipole RF ............................................. 4-8
FT View Frequency........................................................ 4-9
FT Zero Offset............................................................... 4-9
Set Device....................................................................... 4-10
FT Lockmass Abundance ............................................. 4-11
FT Mass Check Test Duration..................................... 4-11
Setting new FT Transfer Optics Parameters ................. 4-11
Display Settings .............................................................. 4-12
Display FT Calibration Settings................................... 4-12
Display FT Diagnostics................................................ 4-13
Display FT Instrument Settings ................................... 4-13