Riello NETMAN102PLUS Datasheet

Category
Networking cards
Type
Datasheet
67


• Sequentialandpriority-basedshutdown:PowerShield
3
providesunattendedshut-
downofsingleandnetworkedPCs,savinganyactiveworkandthemostwidely
usedapplicationsWindows.Userscandefinetheirownshutdownprocedures
andestablishtheorderinwhichcriticalcomputers(suchasservers)aretobe
powereddown
• Multi-platform compatibility: PowerShield
3
uses the TCP/IP communications
protocoltoachievestandardisedmanagementandmonitoringacrossthewidest
possiblerangeofplatforms.Thismakesitpossibletomonitorcomputerswith
different operating systems from a single console, for example monitoring a
UNIXserverfroma PC with Windowsandalso connectingto UPSlocated in
differentgeographicalareasusingdedicatednetworks(intranets)ortheInternet
• Event scheduling: PowerShield
3
users can program their own shutdown
procedures, detailing power-off and power-up scenarios to increase system
safetyand,equallyimportant,powereconomy
• Messagesmanagement:PowerShield
3
keepsusers constantlyinformedabout
thestatusoftheirlocalandnetworkUPS,andenvironmentalsensors.Alistcan
bedefinedofuserswhoshouldreceivee-mailmessages,faxesandSMSwhen
faultsorsuddenmainspowersupplyfailuresoccur
• IntegratedSNMP agent:PowerShield
3
features an integratedSNMP agent for
UPS managementwhich can send all the information requiredand generate
traps using the RFC 1628 MIB standard and environmental sensors. This
All the trademarks indicated are the property of their respective owners.
PowerShield
3
canbedownloadedfreeofchargefrom
CommunicationSoftware
featuremakesitpossilbetomanagetheUPSincompatibleSNMPmanagement
stationssuchasHPOpenView,NovellManagewiseandIBMNetView
• Wapserverintegrated:PowerShield
3
allowstheusertomonitoraUPSthrough
WAPmobilephone
• Security, easy to use and connect, communication is password protected to
ensureUPSsystemsecurity.Usingthenewdiscovery/browsingfunction,allthe
RIELLOUPSconnectedtoaprotectedcomputerorLANcanbedisplayedina
listformat.IntheabsenceofaLANconnection,supportisprovidedformodem-
basedcommunication.
•Windows2000,2003Server,XP,Vista,2008Server,7,onX86,X86_64and
IA64processors
•LinuxonX86,X86_64andIA64processors
•NovellNetware3.x,4.x,5.x,6
•MacOSX
•ThemostcommonUNIXoperatingsystemssuchas:IBMAIX,HP,SUNSolaris
INTELandSPARC,SCOUnixwareandOpenServer,SiliconGraphicsIRIX,Compaq
Tru64UNIXandDECUNIX,OpenBSDUNIXandFreeBSDUNIX,NCRUNIX
•HPOPENVMS
•VMWareESX,VSPHERE
PowerShield
3
providesefficient,user-friendlyUPSmanagementusingbarchartdisplaystoshowmajoroperationalinformationsuchastheinputvoltage,
UPSload%andbatteriescharge%.ThesoftwarealsoprovidesdetailedinformationonfaultconditionsandUPSoperatingcharacteristics.PowerShield
3
has
beendevelopedwithaclient/serverarchitecturethatmakesitflexibleandeasytouse,andprovidesmulti-lingualandon-linesupport.




is a simple but powerful RIELLO UPS management tool. There are various
graphic versions for all the operating systems.


provides all the information required for first level diagnostics.

All changes in UPS operating status are logged and displayed in a graphical format from
which the user can monitor trends in the mains electrical parameters monitored.

The user can select several options remotely: turn the UPS on or off, restart after a power
loss and instigate a battery test.

RIELLO UPS 
software is the only UPS control and shut-down software
running under Macintosh with a client-server cross platform architecture. It allows
integration in TCP/IP networks with Windows, Novell, IBM OS/2 and the most widely
used UNIX operating systems. 
supports the Netman Plus series of network
agents and provides multi-language support.


also displays the UPS in block format providing the user with information
regarding operating status.


can be configured to forward alarm messages automatically via e-mail,
SMS, fax and voice.
68

1.
1.
2.
1.
Netman
Netman
Netman
PowerNETGuard software centralises UPS management using network
interface(SNMP)communications.ItisidealforDataCentremanagers
andmediumtolargesizednetworks.PowerNETGuardusestheRFC1628
standardManagementInformationBase(MIB)andensuresstandardised
UPSmanagementwherevertheyarelocated.
Supervisionsoftware
•CentralisedcontrolofremoteUPSviaEthernetwithSNMPprotocol
Multiple-leveldisplayofgeographicalareas,buildingplans,maps,etc.
Multi-useraccesswithvariouslevelsofsecurity
CompatiblewithNetmanPlusandRFC1628standardnetwork
interface(SNMP)
•Graphsofphysicalinputandoutputvaluesstoredandbackeduptofile
Alarmnotificationviae-mailandSMS
WapServer
Operatingsystemssupported:Windows(98,ME,NT,2000,2003,
XPandVista),Linux,MacOSX,Solaris8,9and10andSilicon
GraphicsIRIX



networkagent
69


Networkagent
Networkagent

TheNetManPlusnetworkagentallowsUPS managementacrossaLANusinganyofthemainnetworkcommunicationprotocols-TCP/IP,HTTP and
networkinterface(SNMP).NetManPlusenabledUPSintegrateeasilyintomediumandlargesizednetworksandprovidereliablecommunicationsbetween
theUPSandmanagementsystemsemployed.
TheNetManPlusnetworkagentallowsUPS managementacrossaLANusinganyofthemainnetworkcommunicationprotocols-TCP/IP,HTTP and
networkinterface(SNMP).NetManPlusenabledUPSintegrateeasilyintomediumandlargesizednetworksandprovidereliablecommunicationsbetween
theUPSandmanagementsystemsemployed.
ConfiguredviaTELNEToraserialterminal
CompatiblewithPowerShield
3
andPowerNETGuardcontrolsoftware
Supportsthenetworkinterface(SNMP)standardcommunication
protocolwithproprietaryRFC1628andMIB
SNMPwithRFC3433tomanagetheenvironmentalsensors
IntegratedWebserverforbrowser-baseddisplay
TeleNetGuardmodemcompatible
Firmwareupgradeablethroughtheserialport
E-mailsentthroughSMTPserver

ConfiguredviaTELNEToraserialterminal
CompatiblewithPowerShield
3
andPowerNETGuardcontrolsoftware
Supportsthenetworkinterface(SNMP)standardcommunication
protocolwithproprietaryRFC1628andMIB
SNMPwithRFC3433tomanagetheenvironmentalsensors
IntegratedWebserverforbrowser-baseddisplay
TeleNetGuardmodemcompatible
Firmwareupgradeablethroughtheserialport
E-mailsentthroughSMTPserver

70

Netman Netman


TheNetmanenvironmentalsensorsmonitorandrecordenvironmentalconditionsaswellasactivitiesinprotectedareasandatthepremiseswheretheUPS
isinstalled.Thesensorsprovideextensivemanagementandcontrol,triggeringcoolingfansandlocksinresponsetochangesintemperatureandhumidity.
Remotemonitoringandcontrolcanbeprovidedviatheinternet,SNMPandtheRielloPowerShield³software.
NetManPluscansupportupto6separatesensors.Theenvironmentalsensorsareeasytoinstallanddonotneedaseparateexternalpowersupply.
Thefollowingsensorsareavailable:
- Sensorfortemperature:-55+125°C
- Sensorfortemperature:-55+125°Candhumidity:0-100%
-Sensorfortemperature:-55+125°CanddigitalI/O:
0-12Vdc.In,1AmaxOut48Vdc
APPLICATION DIAGRAM
Temperature
sensor
Temperature
sensor
Temperature
sensor
Air conditioner
Smoke
detector
APPLICATION DIAGRAM
ProtocolConverter
PortconfigurationforMODBUS/JBUSasRS232orRS485
Managementoftwoindependentseriallines
SuitableforBuildingManagementSystem(BMS)integration
LEDcommunicationflowindicators
Firmwareupgradeablethroughtheserialport

TheMultiCOM301/302protocolconvertermaybeusedtomonitortheUPSusingtheMODBUS/JBUSprotocolonRS232orRS485seriallines.Itcanalso
manageasecondindependentRS232seriallinethatcanbeusedtoconnecttootherdevicessuchastheNetman101oraPCusingPowerShield
3
software.

71



Serial/USBport
MultiCOM362providesaUPSwithanadditionalRS232serialinterfaceorUSBport.TheUSBportallowstheUPStocommunicatewithAppleMacintosh
computersaswellasWindowsandLinuxoperatingsystems.
•CompatiblewithUSB1or2
CompatiblewithPowerShield
3

Seriallinkduplexer
TheMultiCOM351/352isaserialduplexerthatallowstwodevicestobeconnectedtoasingleserialportonaUPS.
ItcanbeusedwherenumerousserialconnectionsandmultipleUPSpollingarerequired,andisidealforLANnetworkswithafirewall.
Cascadingconfigurationgivingamaximumof4serial
communicationports
LEDcommunicationflowindicators
Firmwareupgradeablethroughtheserialport.

Serial/EPOport
MultiCOM372providesaUPSwithanadditionalRS232serialinterfaceport.ThecardhasEmergencyPowerOff(EPO)andRemoteShutDown(RSD)
inputswithterminalconnections.
EPOandUPSshutdowninterface
12Vdc80mAcontactoption


72



Contacts/EPOboard
MultiCOM382providesasetofrelaycontactstoprovideUPSalarmandstatusindication.
Thecontactsareconnectedthroughterminalconnections.SignalcontactsincludeEmergencyPowerOff(EPO),RemoteShutDown(RSD),OnBattery,On
Bypass,AlarmandLowbattery.Thecontactsarechangeoverornormallyopen.
Max.3Acurrentat250Vac
Signalcontactcustomisation

Protocolconverter
MultiI/OhasconfigurableinputandoutputsignalcontactstoallowUPSintegrationwithcontrolsystems.Itcanbeusedtoconnecttwodevicestoasingle
UPSserialcommunicationport.ItcanalsocommunicateusingtheMODBUS/JBUSprotocolonRS485lines.
8analog/digitalinputs
8relayoutputstomonitorUPSandmainsstatus
ItcancontroltwoindependentRS232/RS485seriallinestomonitor
theUPSanditsoperatingstatesusingtheMODBUS/JBUSprotocol
Firmwareupgradeablethroughtheserialport

TheI/Oexpansioncard,fortheMasterPlusrange,isequippedwith:
•6outputswithvoltage-freeNC/NOcontacts(250V/5A),electricallyisolatedfromeachotherandfromothercircuits
•2self-poweredinputs
Eachoutputorinputcanbeconfiguredwithdifferentmeanings,viatherelativemenu.
Expansioncard
73




Protocolconverter
TheMulticom401isanaccessorywithwhichyoucanconnectaUPStoaProfibusDPnetwork.WiththisdevicemanagementandmonitoringoftheUPS
canbeintegratedinacontrolsystembasedononeofthefieldbusesmostwidelyusedinindustryforcommunicationbetweencontrol/automationsystems
anddistributedI/O.
•PROFIBUSDP-V1Protocol
•Configurableaddressfrom0to99
•ProfidriveV2PP05
•Configurablebaudratefrom9.6kBit/sto12MBit/s
•Ledreportingthecommunicationflow

CommunicationKit
TheIBMAS/400hasasingle-levelmemorymanagementfeaturethatmakesitcompulsoryforthesystemtobeshutdowninacontrolledandorderly
manner.WithoutUPSprotectionanAS/400isnotprotectedfrommainsfailures.Amomentarylossofpowercancausehardwaredamage,data
corruptionandalengthyrebootperiod.

•CompatiblewithallAS/400systems
•SupportsalltheRIELLOUPSranges

MultiPanelisaremotemonitoringdevicethatcanprovideadetailedUPSstatusoverviewinrealtime.ItiscompatiblewithallRielloUPSandcandisplay
valuesforUPSspecificinputandoutputsupplies,andbatterysetmeasurements.
MultiPanelhasahigh-definitiongraphicaldisplayandcanreportin7languages:English,Italian,German,French,Spanish,RussianandChinese.Ithas3
independentserialports,oneofwhichallowsforUPSmonitoringviatheMODBUS/JBUSprotocol(oneitheranRS485orRS232serialline).Theothers
canbeusedwithdevicessuchastheNetman101PlusoraPCrunningPowerShield
3
software.
•GraphicalhighdefinitionLCDpanel
•Threeindependentserialconnections
•CompatiblewithmostBMSmanagementprograms
•CommunicationsflowLEDstatusindicator
•Serialportupgradeablefirmware

RemoteMonitoringPanel
74
MODBUS
PROFIBUS
Point-to-point connections
with serial lines
Connections with field bus
with serial lines
somesolutions

Software
Powershield
3
RS232
USB
Software
Powershield
3
RS232
USB
Software
Powershield
3
RS232
USB
Multicom 362
Local
Location
Local
Location
Local
Location
free
free
full license
management PC
RS485 MODBUS
Multicom 301/302
PLC
Multicom 301/302
Multicom 301/302
Local
Location
management PC
Multicom 401
Profibus DP
PLC
Multicom 401
75
TCP/IP Ethernet connections
WAN
Connection with PLC to contacts
TCP/IP Ethernet connections
LAN/WAN
somesolutions
Netman 101/102 plus
Netman 101/102 plus
Netman 101/102 plus
Netman 101/102 plus
SWITCH
SWITCH
internet
Software
PowerNetGuard
Remote
Location
WAN
Netman 101/202 plus
Netman 101/202 plus
Netman 101/202 plus
SWITCH
LAN
WAN
Software
PowerNetGuard
Software
Powershield
3
Server
Remote
Location
Remote
Location
full license
Software
Powershield
3
free
internet
RS232
USB
management PC
Multicom 372
PLC
Local
Location
76
IPLUG 1
IDIALOG 1 1*
DIALOG VISION 1 1 1
PREMIUM PRO 1 1 1
PREMIUM DUAL 1 1 1
DIALOG DUAL 1 1 1
POWER DIALOG 3 1 1 1
MULTI DIALOG 2 1
MULTI PLUS 1 1 3 •
MASTER PLUS / HIP 2 2
USBPort
RS232port
SLOT
UPSModemManagement
MicrosoftPlug&Play
PowerShield
3
NetMan101plus
NetMan102plus
MultiCOM351
MultiCOM352
MultiCOM301
MultiCOM302
MultiCOM362
MultiCOM372
MultiCOM382
MultiCOM401
MultiI/O
ExpansionI/O
MultiCOM401
AS/400Kit
PowerNetGuard
TeleNetGuard
MultiPanel

Standard fittings
Software and optional accessories

  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Riello NETMAN102PLUS Datasheet

Category
Networking cards
Type
Datasheet

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI