MULTIPLEX Model 11, 150 Wall Mount Stand EI206730 Installation guide

Type
Installation guide
In accordance with our policy of continuous product development and improvement,
this information is subject to change at any time without notice.
EI206730 Revision A (KAK) 15 May, 2001
Manitowoc Beverage Equipment
2100 Future Drive Sellersburg, IN 47172-1868
Tel: 812.246.7000, 800.367.4233 Fax: 812.246.9922
www.manitowocbeverage.com
Foodservice Group
Multiplex Beverage Equipment Installation Instructions for
Wall Mount Shelf Kit
For Model 11 Refrigeration Unit and
Beermaster Model 150 Glycol Chiller
(P.N. SS206730)
Caution: To Avoid Serious Injury
Important: Read the following warnings before beginning an
installation. Failure to do so may result in possible death or
serious injury.
DO Adhere to all National and Local Plumbing and Elec-
trical Safety Codes.
DO Turn “off” incoming electrical service switches
when servicing, installing, or repairing equipment.
DO Check that all flare fittings on the carbonation
tank(s) are tight. This check should be performed
with a wrench to ensure a quality seal.
DO Inspect pressure on Regulators before starting up
equipment.
DO Protect eyes when working around refrigerants.
DO Use caution when handling metal surface edges of
all equipment.
DO Handle CO
2 cylinders and gauges with care. Secure
cylinders properly against abrasion.
DO Store CO
2 cylinder(s) in well ventilated areas.
DO NOT Throw or drop a CO
2 cylinder. Secure the cylinder(s)
in an upright position with a chain.
DO NOT Connect the CO
2 cylinder(s) directly to the product
container. Doing so will result in an explosion caus-
ing possible death or injury. Best to connect the
CO
2 cylinder(s) to a regulator(s).
DO NOT Store CO2 cylinders in temperature above 125°F
(51.7°C) near furnaces, radiator or sources of heat.
DO NOT Release CO
2 gas from old cylinder.
DO NOT Touch Refrigeration lines inside units, some may
exceed temperatures of 200°F (93.3°C).
Notice: Water pipe connections and fixtures directly connected
to a potable water supply shall be sized, installed and
maintained in accordance with Federal, State, and Local codes.
2
EI206730 Revision A (KAK) 15 May, 2001
Equipment Installation Instructions
Introduction
The Wall Mount Bracket is designed to mount a Multiplex
Model 11 Refrigeration Unit or a Multiplex Model 150 Beermas-
ter Glycol Chiller on a vertical wall. The kit includes lag screws
for mounting on a wood frame wall. Mounting the Wall Mount
Bracket on a masonry wall requires anchors or toggle bolts
which are not included with this kit.
Required tools
Drill with
7
/32" Drill Bit
4 ft Level
Framing Square
Socket Wrench with
1
/2" and
9
/16" Sockets
8 ft Measuring Tape
Installing the wall mount shelf kit
1. Locate and mark three (3) wall studs at the desired mount-
ing position (refer to figure 1).
2. Measure and mark the location for the top three (3) holes
no closer than 10" (25.4 cm) from the ceiling. Place a 4 ft
Level to span the three (3) studs. Place a mark at each
stud.
3. Measure and mark the two (2) outer studs 22
3
/4" below
the marks marked from step 2 above. Using the Framing
Square, make a vertical mark at the center of each stud.
4. Using the Channel Cleat as a template, align the holes
over the top row of marks. Mark the hole location on the
wall. Repeat this process for the lower row of marks. Mark
the lower hole locations on the wall.
5. Drill six (6) holes
7
/32" in diameter by 1
3
/4" deep as indi-
cated in figure 1.
Figure 1
Mounting Position Template
Figure 2
6. Attach the Channel Cleat to the wall at the upper loca-
tion with
5
/16" x 2" lag screws.
7. Loosely assemble the Support Angles to the ends of the
Channel Cleat using
5
/16" x
3
/4" carriage bolts, spring lock
washers, and hex nuts.
8. Loosely attach the Support Shelf to the Support Angles
with a single carriage bolt through the end hole. Pivot the
back of the shelf up. Align the rear flange with the lower
holes on the wall. Attach the Support Shelf to the wall
using lag screws.
9. Assemble the remaining carriage bolts and tighten all loose
assemblies.
10. Place the Multiplex Refrigeration Unit on the Support Shelf.
Align the mounting holes. Secure the Refrigeration Unit
with
5
/8" x 1" hex head screws and flat washers.
Carriage
Bolt
Lock Washer
Hex Nut
Support
Angle
Lag Screws
Channel
Cleat
Installing the Wall Mount Shelf