Tyco AS0074-000 User manual

Category
Networking
Type
User manual

This manual is also suitable for

DATA SHEET
Input/Output Modules
Features That Make a Difference:
Provides cost-effective expansion of input and output capacity
Compatible with full range of Software House
®
iSTAR and apC
access control panels
Locate modules up to 1,220 m (4,000 ft) away from controllers using
flexible two-wire RS-485 RM bus
Reduces length of sensor and control wiring to save installation
costs
I8 provides eight Class A supervised inputs
R8 provides eight Form C relay outputs
I8-CSI, configurable supervised input model, allows use of existing
input wiring without changing end-of-line (EOL) resistors
Three status LEDs per input (red/yellow/green) and one per output
enable quick diagnostics and troubleshooting
Small, modular size requires minimal panel space
Dedicated tamper input included on each module
Optional UL-listed enclosure available
The Software House I8, R8, and I8-CSI modules provide a
flexible, cost-effective means to expand the input and output
functionality of any iSTAR or apC access controller. Common
applications include alarm monitoring and control and elevator
control.
The I8 input module provides eight Class A supervised inputs.
Three LEDs per input help the installer commission and
troubleshoot each input circuit red if the input is in alarm,
green for normal, and yellow for a supervision error. LEDs may
be turned off via a DIP switch setting.
The I8-CSI module enhances the functionality of the standard
I8 module by supporting numerous supervised circuit types and
EOL resistance values. This allows the I8-CSI to accommodate
existing field wiring without changing EOL resistors. More
than 20 different circuit types are supported. The circuit type
is selected via a bank of DIP switches and applies to all eight
inputs on the I8-CSI.
The R8 output module provides eight Form C dry contact relay
outputs. A red status LED per output shows the state of the
relay.
All modules feature a dedicated input for an external cabinet
tamper switch and mount easily in the Software House RM-CAN
or RM-DCM-CAN enclosure. The modules communicate with
iSTAR or apC controllers via the two-wire RM bus that allows
total wiring distances of up to 1,220 m (4,000 ft). Up to eight I8s
and eight R8s can be connected to each apC, iSTAR eX, and
iSTAR Pro eight-reader model; up to 16 of each module can be
connected to the iSTAR Pro 16-reader model.
The modules are fully compatible with both C•CURE
®
800/8000
and C•CURE 9000.
SPECIFICATIONS
Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies
by region; contact your sales representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.
© 2008 Tyco International Ltd. and its respective companies. All rights reserved. SH0146-DS-200810-R01-LT-EN
www.swhouse.com
(
*
) For plenum or underground applications, use Belden 89182 for one pair 22 AWG, 100 ohm 12.95 pf/ft.
Note: Control, supervised, and unsupervised input cables must be shielded for FCC Class B operation.
General
Dimensions (H x W) .....11.0 x 15.0 cm (4.3 x 5.9 in)
Environmental.......... to 50° C (32° to 122° F); 5 to 85% relative
humidity, non-condensing
Power Input Voltage .....12 VDC +/- 10%
Tamper ...............Dedicated input for external tamper switch
Weight................0.23 kg (8 oz)
Regulatory ............ UL 294, UL 1076, FCC Part A
CE, EN 50133, ROHS
I8 Input Module
Power Requirements ....180 mA @ 12 VDC
Inputs ................Eight Class A supervised
LEDs per Input ......... Red (alarm), green (normal), and yellow
(supervision error)
I8-CSI Input Module
Power Requirements ....80 mA @ 12 VDC
Inputs ................Eight Class A supervised, configurable via DIP switch
LEDs per Input ......... Red (alarm), green (normal) and yellow
(supervision error)
Circuits Supported ...... Single resistor: 1K, 5K, 10K
Double resistor: 1K, 5K, 10K,
1K/2K, 6.8K/18K, 200/10K
Unsupervised: NO, NC
R8 Output Module
Power Requirements ....45 mA @ 12 VDC plus 32 mA per active relay
Outputs...............Eight Form C dry contact relays
LED per Output.........Red (relay active)
Relay Contact Ratings ... 30 VDC, 2.0 A resistive
30 VDC, 1.0 A inductive
125 VAC, 4.0 A
Optional Metal Enclosures with Tamper Switch
RM-DCM-CAN
Dimensions...........356 x 305 x 89 mm (14 x 12 x 3.5 in)
Capacity .............Up to four input or output modules
RM-CAN
Dimensions...........210 x 184 x 83 mm (8.25 x 7.25 x 3.25 in)
Capacity .............One input or output module
Model Numbers
AS0073-001 ...........I8 input module
AS0073-CSI ...........I8-CSI input module
AS0074-000 . . . . . . . . . . .R8 output module
RM-DCM-CAN .........Large metal enclosure with tamper switch
RM-CAN ..............Small metal enclosure with tamper switch
Wiring Summary
Signal From To Belden # Gauge # of Pairs Shielded Maximum Length
Comm
(two-wire RS485)
apC/iSTAR I8/R8 9841* 24 1 Yes
1,220 m
(4,000 ft)
Power apC/iSTAR I8/R8 9841* 24 1 No
Based on
voltage drop
Control Point R8 Strike, Siren, etc. 8442/8461 18 1 No
Based on
voltage drop
Supervised Input I8 REX or Door Contact 8442/8461 22/18 1 No 610 m (2,000 ft)
Wiring Configuration Diagram
I8 Input Module Configuration
R8 Output Module Configuration
0
1
2
3
F
E
D
C
B
A
4
5
6
7
8
9
1
SW1
4
SOFTWARE HOUSE
MADE IN USA
P9
P2
P3
P4
P8
P7
P6
P5
W1
TAMPER
INPUT
P1
R8 OUTPUT MODULE
AS-0074-000 REV.A
NO
NO
NO
NO
NO
NO
NO
NO
NC
NC
NC
NC
NC
NC
NC
NC
C
C
C
C
C
C
C
C
NOTE: All mounting holes are 1/8" dia.
Max. component height 1/2".
23
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
I8-CSI Input Module Configuration
P b
Pb-Fr ee
P5
INE 1
P6
INF 1
P7
ING 1
P8
INH 1
P10P9
GND GNDTS +D -D+12V
1
1
P4
IND 1
P3
INC 1
P2
INB 1
P1
INA 1
S1-1 ON = LED Power
S1-2 ON = Disable Tamper
S1-3 ON = Not Used
S1-4 ON = 485 Termination
DS4
DS25
DS3
DS2
DS27
Y1
DS26
DS1
DS24
DS23
DS22
S3
1 2 3 4
NO
DS21
DS20
DS7
DS6
DS5
DS10
DS9
DS8
DS13
DS12
DS11
S3
DS19
DS18
DS17
DS16
S2
1 2 3 4
ON
DS15
DS14
S2
S1
U3
FOR SWH STD 1K DUAL S2:3-4, S3:1-4 = OFF
SEE QUICKSTART DOC FOR OTHER SETTINGS
CYCLE POWER AFTER SETTING
1234
ON
S1
SW1
1
TYCO
SOFTWARE HOUSE
ASSEMBLED IN USA
C
COPYRIGHT 2007
"WARNING Damage may result from incorrectly
wiring power terminals, input and output lines, and
central-supervising station lines. Check all
connections before powering the unit."
0312–5008–01 Rev.
18–CSI BOARD
®
Input Rating P9
12VDC 125mA
Refer to Quick Start Installation Guide,
P/N UM-218, Rev B0, July 2008
Sample System Configuration: Combination Bus/Star Wiring Diagram
  • Page 1 1
  • Page 2 2

Tyco AS0074-000 User manual

Category
Networking
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI