9) Pass xture wire from threaded tube[O] through coupling[L].
10) Screw coupling[L] onto protruding threads of threaded tube[O] to secure
decorave cap and decorave tube.
11) Pass xture wire from the coupling[L] through a stem[A] and short threaded
tube[B] and screw stem into coupling.
12) Pass xture wire through desired number of stems and screw stems together
using supplied short threaded tubes.
NOTE: Thread locking compound must be applied to all stem threads as
noted with symbol (4) to prevent accidental rotaon of xture during
cleaning, relamping, etc.
13) Aach the assembled square-shaped piece to the curved arms[P] by
inserng a athead screw[Q] through each hole on the arms of the curved
arms[P] and screwing into each hole on top of the corner frames[R].
14) Pass xture wire from last stem through one short threaded tube[B]. Screw
short threaded tube into top of last stem.
15) Pass xture wire through hole in canopy[D]. Lower canopy down towards
stem(s). Pass hole in canopy over end of short threaded tube on top of
stem(s).
16) Pass xture wires through loop of safety cable[AB]. Slip loop of safety cable
over end of short threaded tube protruding from inside of canopy.
17) Pass xture wire through lockwasher[C] and then through hexnut[K]. Place
lockwasher onto end of short threaded tube protruding from inside canopy
and thread hexnut onto short threaded tube, ensuring the lockwasher is
between the hexnut and canopy.
NOTE: Fixture wire should not be cut shorter than 20 inches from above the
canopy.
18) Find the appropriate threaded holes on mounng strap[G]. Assemble
mounng screws[J] into threaded holes.
19) Aach mounng strap to outlet box[F]. The mounng strap can be adjusted
to suit posion of xture using the strap mounng screws[E].
20) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw,
and thread into hole.
b) On xtures where a cupped washer is provided,aach ground wire from
outlet box under cupped washer and green ground screw, then thread
into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector aer following the above steps. Never
connect ground wire to black or white power supply wires.
21) Make wire connecons. Reference chart below for correct connecons and
wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth
(see illus.)
Neutral Wire
22) Aach safety cable to the outlet box. Push xture to ceiling, carefully passing
mounng screws through holes in canopy.
NOTE: Be certain wires do not get pinched between canopy and ceiling.
23) Use knobs[AA] and lockwashers[V] to secure canopy. Tighten to secure.
24) Install the recommended bulbs.
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before
starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical
Code (NEC) and all local code specicaons. If you are not familiar with code
requirements, installaon by a cered electrician is recommended.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a so damp cloth should be used. Harsh cleaning products may damage
the nish.
Installaon Instrucons
[A] Stems
[B] Short Threaded
Tubes
[C] Lockwasher
[D] Canopy
[E] Stap Mounting
Screws
[F] Outlet Box
[G] Mounting Stap
[H] First Loop
[I] Chain Link
[J] Mounting Screws
[K] Hexnut
[L] Coupling
[M] Decorative End Cap
[N] Decorative Tube
[O] Threaded Tube
[P] Curved Arms
[Q] Flathead Screw
[R] Corner Frame
[S] Finials
[T] Studded Finials
[U] Glass Panel
[V] Lockwashers
[W] Main Body
[X] Studded Lock Up
Knobs
[Y] Hexnuts
[Z] Second Loop
[AA] Knobs
[AB] Safety Cable
RIGID STEM MOUNT
1) Assemble the four curved arms[P] as shown using the four (4) studded lock
up knobs[X] and four (4) hexnuts[Y] and rotate the four (4) arms into their
correct locaons as shown in view.
2) Aach corner frame[R] to long edge of glass panel[U] by aligning the two
(2) holes in the corner frame with the two (2) holes along the long edge of
glass panel. Glass panel should be on INSIDE of corner frame. Insert studded
nials[T] into two (2) holes in glass and two (2) holes in corner frames and
secure with two (2) nials[S] on outside of corner frames. Repeat to aach
another corner frame[R] to the other long edge of the glass panel[U].
3) Repeat Step 2 using the two (2) remaining corner frames[R] and another
glass panel[U].
4) Aach one remaining glass panel[U] to one corner frame[R] from Step 2
and one corner frame[R] from Step 3 using the available holes in the corner
frames and the same fastening method described in Step 2. Repeat for
aaching the nal glass panel[U].
NOTE: At this point, you should have one assembled square-shaped piece
consisng of the four (4) corner frames and the four (4) glass panels.
5) Pass xture wire from coupling on top of main body[W] through threaded
tube[O].
6) Screw threaded tube[O] into coupling on top of main body[W].
7) Slide decorave tube[N] over threaded tube[O] so that threads on threaded
tube are protruding out from the end of the decorave tube.
8) Slide decorave end cap[M] over exposed threads onto decorave tube[N].
LOOP / CHAIN LINK MOUNT
1) Follow steps 1-13 from Rigid Stem Mount Instrucons.
2) Pass xture wire from last stem through short threaded tube[B] and through
rst loop[H]. Screw short threaded tube into top of last stem and into rst loop.
3) Pass xture wire through second loop[Z], short threaded tube, and through
hole in canopy. Screw short threaded tube into second loop (If second loop is
already aached to canopy, proceed to next step). Insert short threaded tube at
end of second loop through hole in canopy. Pass xture wires through loop of
safety cable[AB] and lockwasher[C]. Slip loop of safety cable over end of short
threaded tube protruding from inside of canopy. Thread lockwasher[C] onto
short threaded tube protruding from inside canopy. Pass xture wire through
hexnut[K] and thread hexnut onto end of short threaded tube.
NOTE: Fixture wire should not be cut shorter than 20 inches from above the
canopy.
4) Aach open chain link[I] to loop at end of stem(s) and to loop on canopy. Once
aached, close the open chain link by placing a piece of cloth over the open link
and using a pair of pliers to gently squeeze the link closed.
5) Follow Steps 18-24 from Rigid Stem Mounng Instrucons.
F
G
E
K
J
C
D
AA
Z
H
I
B
A
L
►
►
►
V
M
N
O
R
T
S
T
U
B
B
P
Y
W
AB
S
Q
X
Installaon Instrucons (connued)
F
G
E
K
J
C
D
AA
Z
H
I
B
A
L
►
►
►
V
M
N
O
R
T
S
T
S
T
R
U