14) Grounding instrucons: (See Illus. a or b).
a) On xtures where mounng strap is provided with a hole and two raised
dimples, wrap ground wire from outlet box around green ground screw,
and thread into hole.
b) On xtures where a cupped washer is provided,aach ground wire from
outlet box under cupped washer and green ground screw, then thread
into mounng strap.
If xture is provided with ground wire, connect xture ground wire to outlet
box ground wire with wire connector aer following the above steps. Never
connect ground wire to black or white power supply wires.
15) Make wire connecon. Reference chart below for correct connecons and
wire accordingly.
Connect Black or Red
Supply Wire to:
Connect White Supply
Wire to:
Black White
*Parallel cord (round &
smooth)
*Parallel cord (square &
ridged)
Clear, Brown, Gold or
Black without Tracer
Clear, Brown, Gold or Black
with Tracer
Insulated wire (other
than green) with copper
conductor
Insulated wire (other
than green) with silver
conductor
*Note: When parallel wire (SPT
1 & SPT 2) are used. The neutral
wire is square shaped or ridged
and the other wire will be round
in shape or smooth
(see illus.)
Neutral Wire
16) Push xture to ceiling, carefully passing threaded pipe through hole in
canopy[H].
NOTE: Be certain wires do not get pinched between mounng strap and
canopy, or canopy and ceiling.
17) Secure xture to ceiling with lock-up knob[N].
18) Insert recommended bulbs. (Not supplied).
GREEN GROUND
SCREW
CUPPED
WASHER
OUTLET BOX
GROUND
FIXTURE
GROUND
DIMPLES
WIRE CONNECTOR
OUTLET BOX
GROUND
GREEN GROUND
SCREW
FIXTURE
GROUND
a
b
Fixture Diagram
Parts List
Cauons
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fusebox before
starng and during the installaon.
WARNING:
This xture is intended for installaon in accordance with the Naonal Electrical
Code (NEC) and all local code specicaons. If you are not familiar with code
requirements, installaon by a cered electrician is recommended.
CLEANING:
• Always be certain that electric current is turned o before cleaning.
• Only a so damp cloth should be used. Harsh cleaning products may damage
the nish.
Installaon Instrucons
[A] Stems
[B] Short Threaded
Tubes
[C] Outlet Box
[D] Safety Cable
[E] Lockwasher
[F] Hexnut
[G] Mounting Strap
[H] Canopy
[I] Strap Mounting
Screws
[J] Threaded Pipe
[K] Hexnut
[L] Second Loop
[M] Chain Link
[N] Lock-up Knob
[O] Fixture Body
[P] Ground Wire Loop
[Q] First Loop
RIGID STEM MOUNT
1) On side of xture with xture wires, Pass xture wires through stems[A] and
short threaded tubes[B]. Screw stems together using short threaded tubes
and screw stems into coupling on xture body[O] using a short threaded
tube.
2) On opposite side of xture (without xture wires) screw a second set of
stems together using short threaded tubes (same number of stems and short
threaded tubes from previous step but without xture wire) and screw stems
into opposite coupling on xture body using a short threaded tube.
NOTE: Thread locking compound must be applied to all stem threads as
noted with symbol (4) to prevent accidental rotaon of xture during
cleaning, relamping, etc.
3) On side of xture with xture wires, pass xture wires through one short
threaded tube[B]. Screw short threaded tube onto top of stem.
4) On opposite side of xture (without xture wires), screw one short threaded
tube onto top of stem.
5) Pass xture wires through hole in canopy[H]. Lower canopy down towards
stems. Pass holes in canopy over ends of short threaded tubes on top of the
stems.
6) On side of xture with xture wires, pass xture wires through loop of
safety cable[D]. Slip loop of safety cable over end of short threaded tube
protruding from inside of canopy.
7) Pass xture wires through lockwasher[E]. Place lockwasher onto end of
short threaded tube protruding from inside canopy.
8) Pass xture wires through hexnut[F]. Thread hexnut onto end of short
threaded tube.
NOTE: Fixture wires should not be cut shorter than 20 inches from above the
canopy.
9) On opposite side of xture (without xture wires), place loop of ground
wire[P] over short threaded tube protruding from inside of canopy and
secure into place with a lock washer and hexnut as shown.
10) Take threaded pipe[J] from parts bag and screw in mounng strap[G] a
minimum of 6 mm (1/4”). Lock into place with hexnut[K].
11) Run another hexnut down threaded pipe almost touching rst hexnut.
Mounng strap must be posioned with extruded thread faced into outlet
box[C]. Threaded pipe must protrude out the back of mounng strap. Screw
third hexnut onto end of threaded pipe protruding from back of mounng
strap.
12) Aach mounng strap to outlet box[C] using the strap mounng screws[I].
Mounng strap can be adjusted to suit posion of xture.
13) Aach safety cable to the mounng strap by looping over the strap and
secure into place to prevent damage to the wires during wiring.
Installaon Instrucons (connued)
LOOP / CHAIN LINK MOUNT
1) Follow steps 1 and 2 from “Rigid Stem Mount Instrucons.
2) Thread one short threaded tube[B] into end of each small loop[Q, L].
3) On side of xture with xture wires, pass xture wires through rst loop[Q].
Thread rst loop onto end of last stem.
4) Pass xture wires through second loop[L] and through hole in canopy[H]. Pass
short threaded tube at end of second loop through hole in canopy.
5) Pass xture wires through loop of safety cable[D]. Slip loop of safety cable over
end of short threaded tube protruding from inside of canopy.
6) Pass xture wires through lockwasher[E]. Place lockwasher onto end of short
threaded tube protruding from inside canopy.
7) Pass xture wires through hexnut[F]. Thread hexnut onto end of short threaded
tube.
NOTE: Fixture wires should not be cut shorter than 20 inches from above the
canopy.
8) On opposite side of xture (without xture wires), Thread rst loop[Q] onto
end of last stem. Pass threaded pipe at end of second loop[L] through hole in
canopy.
9) Place loop of ground wire[P] over short threaded tube protruding from inside of
canopy and secure into place with a lock washer and hexnut as shown.
10) Aach open chain link[M] to small loops at end of each stem and to small loops
on canopy and close the open chain link by placing a piece of cloth over the
open link and using a pair of pliers gently squeeze the link closed.
11) Follow steps 10 - 18 from “Rigid Stem Mount Instrucons.
A
M
Q
B
B
N
P
D
F
E
H
C
G
I
J
K
O
B
L
F
E
M
L
Q