Cumberland 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series Owner's manual

Type
Owner's manual
PNEG-1461
12', 15', 18' and 21' Bulk Feed
Tank Series and Grain Hopper
Tank Series
Assembly Manual
PNEG-1461
Version: 22.0
Date: 10-14-22
2 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
All information, illustrations, photos and specifications in this manual are based on the latest
information available at the time of publication. The right is reserved to make changes at any
time without notice.
Table of Contents
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 3
Contents
Chapter 1 Introduction ..........................................................................................................................................5
Chapter 2 Safety .....................................................................................................................................................6
Safety Guidelines .................................................................................................................................. 6
Cautionary Symbols Definitions ............................................................................................................ 7
Safety Cautions ..................................................................................................................................... 8
Safety Sign-Off Sheet ......................................................................................................................... 11
Chapter 3 Safety Decals ......................................................................................................................................12
Chapter 4 General Information ...........................................................................................................................13
Bulk Feed Tank Assembly Manual General Instructions .................................................................... 13
Chapter 5 Foundation ..........................................................................................................................................14
Chapter 6 Sidewall Assembly .............................................................................................................................25
Bulk Feed Tank Assembly .................................................................................................................. 25
12' Sidewall Sheet Orientation ............................................................................................................ 26
Sidewall Erection ................................................................................................................................. 27
Chapter 7 Roof .....................................................................................................................................................31
12'-18' BFT Sealed Roof Panel Installation ......................................................................................... 31
Peak Ring Collar to Roof Panels ......................................................................................................... 32
12' Roof Reinforcement Angle ............................................................................................................ 33
15' and 18' Roof Assembly Instructions .............................................................................................. 34
Raising the Roof .................................................................................................................................. 37
Chapter 8 Optional BFT Ladder Assembly ........................................................................................................39
Ladder Assembly Parts ....................................................................................................................... 39
Sidewall and Roof Ladders Assembly ................................................................................................. 40
Roof Ladder Support Bracket Installation ........................................................................................... 41
Standoff Bracket Installation ............................................................................................................... 44
Ladder Standoff Installation ................................................................................................................ 45
Ladder Section Assembly ................................................................................................................... 46
Ladder Support Detail ......................................................................................................................... 47
Ladder Decal Application .................................................................................................................... 47
Chapter 9 Safety Cage .........................................................................................................................................48
Ladder System with Safety Cage ........................................................................................................ 48
Safety Cage Hoop Assembly .............................................................................................................. 50
Safety Cage Installation ...................................................................................................................... 52
Chapter 10 Roof Cap and Ground Control Installation ....................................................................................55
Installing the BFT Cone Lid (BLK-13062) .......................................................................................... 55
BFT Cone Lid Parts List (BLK-13062) ............................................................................................... 60
Installing the GHT Flat Roof Cap with Ground Control (BLK-11651) ................................................ 61
GHT Flat Roof Cap with Ground Control Parts List (BLK-11651) ..................................................... 64
Cap Hold-Down Package .................................................................................................................. 65
Roof Cap Seal Kit (Optional) ............................................................................................................. 65
Table of Contents
4 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
Chapter 11 Hopper Assembly .............................................................................................................................66
Hopper Reinforcement Angle Installation for 12' Bin ......................................................................... 66
Installing the 15' Diameter 60° Hopper Bin Assembly ....................................................................... 67
18' Diameter 45° and 21' Diameter 45° Hopper Bin Assembly .......................................................... 73
Hopper Collar Assembly .................................................................................................................... 76
Attaching the Collar to the Hopper Panel (12' Tanks Only) ............................................................... 78
Chapter 12 Legs and Leg Bracing ......................................................................................................................79
12' Only .............................................................................................................................................. 79
Installation of Leg to Sidewall ............................................................................................................ 80
Installation of Leg to Sidewall for 15', 18' and 21' BFT ...................................................................... 81
12'-21' Leg Bracing ............................................................................................................................ 82
Bracing Hole Layouts ........................................................................................................................ 84
Hopper to Leg Bracing for 12', 18' and 21' ........................................................................................ 88
Hopper to Leg Bracing for 15' ............................................................................................................ 89
Chapter 13 Raising Bin ........................................................................................................................................90
Raising Bin to Set on Foundation ...................................................................................................... 90
Standard Hopper Bin Anchoring ........................................................................................................ 90
Anchoring Tank ................................................................................................................................. 91
Bin Grounding Instructions ................................................................................................................ 92
Chapter 14 Pneumatic Fill Kit .............................................................................................................................93
Pneumatic Fill Kit Assembly .............................................................................................................. 93
Roof Panel ......................................................................................................................................... 94
Chapter 15 Parts List ...........................................................................................................................................95
12' Diameter 60° Hopper Bin Specifications ...................................................................................... 96
12' Diameter 60° Hopper Bin Hardware Specifications ..................................................................... 98
12' Diameter 45° Hopper Bin Specifications .................................................................................... 100
12' Diameter 45° Hopper Bin Hardware Specifications ................................................................... 102
15' Diameter 60° Hopper Bin Specifications .................................................................................... 104
15' Diameter 60° Hopper Bin Hardware Specifications ................................................................... 106
15' Diameter 45° Hopper Bin Specifications .................................................................................... 108
15' Diameter 45° Hopper Bin Hardware Specifications ................................................................... 110
18' Diameter 45° Hopper Bin Specifications .................................................................................... 112
18' Diameter 45° Hopper Bin Hardware Specifications ................................................................... 114
21' Diameter 45° Hopper Bin Specifications .................................................................................... 116
21' Diameter 45° Hopper Bin Hardware Specifications ................................................................... 118
Chapter 16 Warranty ..........................................................................................................................................121
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 5
1. Introduction
READ THIS MANUAL carefully to learn how to properly use and install equipment. Failure to do so could
result in personal injury or equipment damage.
INSPECT the shipment immediately upon arrival. The customer is responsible for ensuring that all
quantities are correct. The customer should report and note any damage or shortage on the bill of
lading to justify their claim to the transport company.
THIS MANUAL SHOULD BE CONSIDERED a permanent part of your equipment and should be easily
accessible when needed.
This warranty provides you the assurance that the company will back its products when defects appear
within the warranty period. In some circumstances, the company also provides field improvements, often
without charge to the customer, even if the product is out of warranty. Should the equipment be abused,
or modified to change its performance beyond the factory specifications, the warranty will become void
and field improvements may be denied.
6 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
2. Safety
Safety Guidelines
Safety guidelines are general-to-specific safety rules that must be followed at all times. This manual is
written to help you understand safe operating procedures and problems that can be encountered by the
operator and other personnel when using this equipment. Read and save these instructions.
As owner or operator, you are responsible for understanding the requirements, hazards, and precautions
that exist and to inform others as required. Unqualified persons must stay out of the work area at all times.
Alterations must not be made to the equipment. Alterations can produce dangerous situations resulting in
SERIOUS INJURY or DEATH.
This equipment must be installed in accordance with the current installation codes and applicable
regulations, which must be carefully followed in all cases. Authorities having jurisdiction must be consulted
before installations are made.
When necessary, you must consider the installation location relative to electrical, fuel and water utilities.
Personnel operating or working around equipment must read this manual. This manual must be delivered
with equipment to its owner. Failure to read this manual and its safety instructions is a misuse of the
equipment.
ST-0001-4
2. Safety
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 7
Cautionary Symbols Definitions
Cautionary symbols appear in this manual and on product decals. The symbols alert the user of potential
safety hazards, prohibited activities and mandatory actions. To help you recognize this information, we
use the symbols that are defined below.
NOTICE
DANGER
WARNING
CAUTION
This symbol indicates an imminently hazardous situation
which, if not avoided, will result in serious injury or death.
This symbol indicates a potentially hazardous situation
which, if not avoided, can result in serious injury or death.
This symbol indicates a potentially hazardous situation which,
if not avoided, can result in minor or moderate injury.
This symbol is used to address practices not related to
personal injury.
This symbol indicates a general hazard.
This symbol indicates a prohibited activity.
This symbol indicates a mandatory action.
ST-0005-2
2. Safety
8 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
Safety Cautions
Use Personal Protective Equipment
Eye
Protection
Hearing
Protection
Hand
Protection
Head
Protection
Respiratory
Protection
Foot
Protection
Fall
Protection
• Use appropriate personal protective equipment:
• Wear clothing appropriate to the job.
• Remove all jewelry.
• Tie long hair up and back.
ST-0004-1
Follow Safety Instructions
• Carefully read all safety messages in this manual and
safety signs on your machine. Keep signs in good
condition. Replace missing or damaged safety signs. Be
sure new equipment components and repair parts include
the current safety signs. Replacement safety signs are
available from the manufacturer.
• Learn how to operate the machine and how to use controls
properly. Do not let anyone operate without instruction.
• If you do not understand any part of this manual or need
assistance, contact your dealer.
ST-0002-1
ST-0057-1
2. Safety
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 9
Maintain Equipment and Work Area
• Understand service procedures before doing work. Keep area
clean and dry.
• Never service equipment while it is operating. Keep hands, feet,
and clothing away from moving parts.
• Keep your equipment in proper working condition. Replace worn
or broken parts immediately.
ST-0003-1
Sharp Edge Hazard
• This product has sharp edges, which can cause serious injury.
• To avoid injury, handle sharp edges with caution and always use
proper protective clothing and equipment.
ST-0036-2
Store Bin Sheets Properly
• Sidewall bundles or sheets must be stored in a safe manner.
The safest method of storing sidewall bundles is by laying them
horizontally with the arch of the sheet upward, like a dome.
• Sidewall sheets stored on edge must be secured so that they cannot
fall over and cause injury.
• Use care when handling and moving sidewall bundles.
ST-0058-2
Stay Clear of Hoisted Equipment
• Always use proper lifting or hoisting equipment when assembling or
disassembling equipment.
• Do not walk or stand under hoisted equipment.
• Always use sturdy and stable supports when needed for installation.
Not following these safety precautions creates the risk of falling
equipment, which can crush personnel and cause serious injury
or death.
ST-0047-1
2. Safety
10 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
> 300 lbs
(1.34 kN)
ST-0059-2
ST-0061-1
2. Safety
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 11
Safety Sign-Off Sheet
Below is a sign-off sheet that can be used to verify that all personnel have read and understood the safety
instructions. This sign-off sheet is provided for your convenience and personal record keeping.
Date Employee Name Supervisor Name
ST-0007
12 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
3. Safety Decals
The safety decals on your equipment are safety indicators which must be carefully read and understood
by all personnel involved in the installation, operation, service and maintenance of the equipment.
To replace a damaged or missing decal, contact us to receive a free replacement.
GSI Decals
1004 E. Illinois St.
Assumption, IL 62510
Tel: 1-217-226-4421
Location Decal No. Decals Description
Located on
the inside
of the bin
collar
DC-2123
Danger, Keep
Clear of
Augers
Located on
the bin
ladders
DC-2307
Danger, Do not
exceed load
limit
Located on
the BFT lid DC-2484
Warning, Do
not enter center
fill opening
DANGERDANGER
Rotating flighting will
kill or dismember.
Flowing material will
trap and suffocate.
Crusted material will
collapse and suffocate. DC-2123
GSI Group 217-226-4421
DC-2307GSI Group, 217-226-4421
DANGER
DO NOT EXCEED LADDER
LOAD LIMIT
Load limit = 300 LBS (136 kg)
Excessive load will damage
ladder resulting in injury or death.
> 300 lbs
(136 kg)
WARNING
GSI Group 217-226-4421 DC-2484
Entrapment Hazard!
Center fill opening is not a
personnel access point. Do not
enter.
Failure to heed these warnings
could result in serious injury or
death.
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 13
4. General Information
Bulk Feed Tank Assembly Manual General Instructions
First, read the assembly manual completely before starting to assemble the Bulk Feed Tank. Check the
shipment with the packing list to be sure there are no shortages.
1. Decal protective mask must be removed when assembling tank. Use soapy water to soak the decal
protective mask for 5 minutes to ease removal.
2. Vertical seams must be staggered on all sidewall rings.
3. When legs extend up 2 rings, the leg holes must be in alignment in the bottom 2 rings.
4. All hopper seams and the hopper collar use truss head bolts. The heads of the bolts must be on the
inside of the tank.
5. Hex head bin bolts are used on all sidewall and roof seams with the bolt heads on the outside of
the bin.
6. Hex head bolts are to be used on all leg to sidewall connections with the bolt heads on the inside of
the tank.
7. All bolts are to be tightened from the nut side only. Do not allow bolt heads to spin.
8. Drift punches can be used to align holes.
9. All vertical sidewall sheet seams must be overlapped in the same direction.
10. A hole spacing of 3-1/8" is used at the top of all top sidewall sheets and at the bottom of all bottom
sidewall sheets.
Selecting the Proper Site
The selected site should be level, firm and free from underlying debris. The tank can be installed
satisfactorily on slopes, but as the slope increases, additional labor and materials are required for the
foundation. The concrete foundation surfaces must be level. If some fill is required, it should be watered
and tamped thoroughly to prevent uneven settling from the weight of the tank. Good water drainage should
be provided to prevent water collecting under or around the tank. The site must allow convenient access
for loading and unloading and plus provide additional space for future units. Also, consider the positioning
of handling equipment, availability of electricity, etc.
Tools
Tools recommended for assembly of Bulk Feed Tanks.
1. Assorted sizes of combination wrenches
2. Hammer
3. 3-12" Long drift punches
4. 1 Large flathead screwdriver
5. 1 Pair of slip joint pliers
6. Two (2) adjustable wrenches
7. Ratchet and sockets
8. Impact wrenches and sockets (if available)
14 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
5. Foundation
Figure 5A 12' 2-8 Rings BFT/GHT Square Pad
# of
Rings
Slab
Thickness (D)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
2-5 15" 9.1 Cu. Yards 196 Sq. Ft. 8
6 16" 9.7 Cu. Yards 196 Sq. Ft. 8
716" 9.7 Cu. Yards 196 Sq. Ft. 8
8 17" 10.3 Cu. Yards 196 Sq. Ft. 8
# of
Rings
Slab
Thickness (D)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
2-5 381 mm 6.93 Cu. Meters 18.21 Sq. Meters 8
6 406 mm 7.40 Cu. Meters 18.21 Sq. Meters 8
7406 mm 7.40 Cu. Meters 18.21 Sq. Meters 8
8 432 mm 7.86 Cu. Meters 18.21 Sq. Meters 8
GENERAL NOTES:
1. Foundation recommendations are based on 3500 lbs./ft.^2 allowable
soil bearing capacity.
2. Foundation recommendations are based on a minimum compressive
strength of 3000 PSI at 28 days.
3. The foundation site must be well drained and free of vegetation
and debris.
4. The foundation should be level within 1/4" overall and within
± 1/8" in any 10 ft. length along the anchor bolt circle.
5. Material estimates do not include allowance for shrinkage and waste.
6. These layouts are recommendations for GSI tanks only. Consult GSI
engineering for special tank foundations.
* Applies to 45° hopper tank only.
All instructions shall be construed as recommendations only. The actual
installation may vary according to local conditions. The GSI Group assumes
no liability for results arising from the use of such recommendations.
*
*
Anchor bolt 5/8" x 8" (203 mm) bolt with a
1/8" thick x 1-3/4" O.D. washer on head.
6" Maximum
Grade
5. Foundation
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 15
Figure 5B 12' 2-8 Rings BFT/GHT Round Pad
# of
Rings
Slab
Thickness (D)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
2-5 15" 7.1 Cu. Yards 155 Sq. Ft. 8
6 16" 7.6 Cu. Yards 155 Sq. Ft. 8
716" 7.6 Cu. Yards 155 Sq. Ft. 8
8 17" 8.1 Cu. Yards 155 Sq. Ft. 8
# of
Rings
Slab
Thickness (D)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
2-5 381 mm 5.45 Cu. Meters 14.40 Sq. Meters 8
6 406 mm 5.81 Cu. Meters 14.40 Sq. Meters 8
7406 mm 5.81 Cu. Meters 14.40 Sq. Meters 8
8 432 mm 6.18 Cu. Meters 14.40 Sq. Meters 8
GENERAL NOTES:
1. Foundation recommendations are based on 3500 lbs./ft.^2 allowable
soil bearing capacity.
2. Foundation recommendations are based on a minimum compressive
strength of 3000 PSI at 28 days.
3. The foundation site must be well drained and free of vegetation
and debris.
4. The foundation should be level within 1/4" overall and within
± 1/8" in any 10 ft. length along the anchor bolt circle.
5. Material estimates do not include allowance for shrinkage and waste.
6. These layouts are recommendations for GSI tanks only. Consult GSI
engineering for special tank foundations.
* Applies to 45° hopper tank only.
All instructions shall be construed as recommendations only. The actual
installation may vary according to local conditions. The GSI Group assumes
no liability for results arising from the use of such recommendations.
*
*
6" Maximum
Grade
Anchor bolt 5/8" x 8" (203 mm) bolt with a
1/8" thick x 1-3/4" O.D. washer on head.
8 Legs
5. Foundation
16 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
Figure 5C 12' 8-10 Rings BFT/GHT Round Pad
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
815" 4" 5.0 Cu. Yards 175 Sq. Ft. 12
9 18" 4" 5.8 Cu. Yards 175 Sq. Ft. 12
10 20" 4" 6.4 Cu. Yards 175 Sq. Ft. 12
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
8381 mm 102 mm 3.82 Cu. Meters 16.26 Sq. Meters 12
9 457 mm 102 mm 4.43 Cu. Meters 16.26 Sq. Meters 12
10 508 mm 102 mm 4.89 Cu. Meters 16.26 Sq. Meters 12
GENERAL NOTES:
1. Foundation recommendations are based on 3500 lbs./ft.^2 allowable
soil bearing capacity.
2. Foundation recommendations are based on a minimum compressive
strength of 3000 PSI at 28 days.
3. The foundation site must be well drained and free of vegetation
and debris.
4. The foundation should be level within 1/4" overall and within
± 1/8" in any 10 ft. length along the anchor bolt circle.
5. Material estimates do not include allowance for shrinkage and waste.
6. These layouts are recommendations for GSI tanks only. Consult GSI
engineering for special tank foundations.
* Applies to 60° hopper tank only.
** Applies to 45° and 60° hopper tanks.
All instructions shall be construed as recommendations only. The actual
installation may vary according to local conditions. The GSI Group assumes
no liability for results arising from the use of such recommendations.
*
**
*
**
Grade
6" Maximum
Anchor bolt 5/8" x 8" (203 mm) bolt with a
1/8" thick x 1-3/4" O.D. washer on head.
12 Legs
5. Foundation
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 17
Figure 5D 12' 11 Rings BFT/GHT 16 Leg Round Pad
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
11 24" 4" 7.5 Cu. Yards 175 Sq. Ft. 16
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
11 610 mm 102 mm 5.73 Cu. Meters 16.26 Sq. Meters 16
GENERAL NOTES:
1. Foundation recommendations are based on 3500 lbs./ft.^2 allowable
soil bearing capacity.
2. Foundation recommendations are based on a minimum compressive
strength of 3000 PSI at 28 days.
3. The foundation site must be well drained and free of vegetation
and debris.
4. The foundation should be level within 1/4" overall and within
± 1/8" in any 10 ft. length along the anchor bolt circle.
5. Material estimates do not include allowance for shrinkage and waste.
6. These layouts are recommendations for GSI tanks only. Consult GSI
engineering for special tank foundations.
All instructions shall be construed as recommendations only. The actual installation
may vary according to local conditions. The GSI Group assumes no liability for
results arising from the use of such recommendations.
6" Maximum
Grade
Anchor bolt 5/8" x 8" (203 mm) bolt with a
1/8" thick x 1-3/4" O.D. washer on head.
16 Legs
5. Foundation
18 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
Figure 5E 15' 1-6 Rings BFT/GHT Round Pad
# of
Rings
Slab
Thickness (D)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
1-4 14" 11.0 Cu. Yards 255 Sq. Ft. 15
5 15" 11.8 Cu. Yards 255 Sq. Ft. 15
616" 12.6 Cu. Yards 255 Sq. Ft. 15
# of
Rings
Slab
Thickness (D)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
1-4 356 mm 8.41 Cu. Meters 23.69 Sq. Meters 15
5 381 mm 9.01 Cu. Meters 23.69 Sq. Meters 15
6406 mm 9.63 Cu. Meters 23.69 Sq. Meters 15
GENERAL NOTES:
1. Foundation recommendations are based on 3500 lbs./ft.^2 allowable
soil bearing capacity.
2. Foundation recommendations are based on a minimum compressive
strength of 3000 PSI at 28 days.
3. The foundation site must be well drained and free of vegetation
and debris.
4. The foundation should be level within 1/4" overall and within
± 1/8" in any 10 ft. length along the anchor bolt circle.
5. Material estimates do not include allowance for shrinkage and waste.
6. These layouts are recommendations for GSI tanks only. Consult GSI
engineering for special tank foundations.
All instructions shall be construed as recommendations only. The actual
installation may vary according to local conditions. The GSI Group assumes
no liability for results arising from the use of such recommendations.
Grade
6" Maximum
Anchor bolt 5/8" x 8" (203 mm) bolt with a
1/8" thick x 1-3/4" O.D. washer on head.
15 Legs
5. Foundation
PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series 19
Figure 5F 15' 7-8 Rings BFT/GHT 60° Round Pad
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
714" 4" 6.3 Cu. Yards 225 Sq. Ft. 20
8 15" 4" 6.6 Cu. Yards 225 Sq. Ft. 20
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
7356 mm 102 mm 4.82 Cu. Meters 20.9 Sq. Meters 20
8 381 mm 102 mm 5.05 Cu. Meters 20.9 Sq. Meters 20
GENERAL NOTES:
1. Foundation recommendations are based on 3500 lbs./ft.^2 allowable
soil bearing capacity.
2. Foundation recommendations are based on a minimum compressive
strength of 3000 PSI at 28 days.
3. The foundation site must be well drained and free of vegetation
and debris.
4. The foundation should be level within 1/4" overall and within
± 1/8" in any 10 ft. length along the anchor bolt circle.
5. Material estimates do not include allowance for shrinkage and waste.
6. These layouts are recommendations for GSI tanks only. Consult GSI
engineering for special tank foundations.
All instructions shall be construed as recommendations only. The actual installation
may vary according to local conditions. The GSI Group assumes no liability for
results arising from the use of such recommendations.
6" Maximum
Grade
20 Legs
Anchor bolt 5/8" x 8" (203 mm) bolt with a
1/8" thick x 1-3/4" O.D. washer on head.
5. Foundation
20 PNEG-1461 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series
Figure 5G 15' 7-8 Rings BFT/GHT 45° Hopper Tank
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
717" 4" 7.4 Cu. Yards 225 Sq. Ft. 15
8 18" 4" 7.7 Cu. Yards 225 Sq. Ft. 15
# of
Rings
Footing
Depth (D)
Slab
Thickness (T)
Concrete
Volume
Wire Mesh
Area
# of Column
Legs
7432 mm 102 mm 5.66 Cu. Meters 20.90 Sq. Meters 15
8 457 mm 102 mm 5.89 Cu. Meters 20.90 Sq. Meters 15
GENERAL NOTES:
1. Foundation recommendations are based on 3500 lbs./ft.^2 allowable
soil bearing capacity.
2. Foundation recommendations are based on a minimum compressive
strength of 3000 PSI at 28 days.
3. The foundation site must be well drained and free of vegetation
and debris.
4. The foundation should be level within 1/4" overall and within
± 1/8" in any 10 ft. length along the anchor bolt circle.
5. Material estimates do not include allowance for shrinkage and waste.
6. These layouts are recommendations for GSI tanks only. Consult GSI
engineering for special tank foundations.
All instructions shall be construed as recommendations only. The actual
installation may vary according to local conditions. The GSI Group assumes
no liability for results arising from the use of such recommendations.
6" Maximum
Grade
15 Legs
Anchor bolt 5/8" x 8" (203 mm) bolt with a
1/8" thick x 1-3/4" O.D. washer on head.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122

Cumberland 12', 15', 18' and 21' Bulk Feed Tank Series and Grain Hopper Tank Series Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI