Dell C61 User manual

  • Hello! I am an AI chatbot trained to assist you with the Dell C61 User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
D
Usin
g
D
ell P
o
the B
a
Ma
n
C
o
werE
d
C6
a
sebo
a
n
a
g
em
e
C
ontro
l
d
ge
1
45
a
rd
e
nt
l
ler
___________
Information in this publication is subject to change without notice.
© 2011 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission
of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, and PowerEdge™ are trademarks of
Dell Inc. Microsoft
®
and Windows
®
are registered trademarks of Microsoft Corporation.
Linux
®
is a registered trademark of Red Hat, Inc. in the United States and/or other
countries.
Other trademarks and trade names may be used in this publication to refer to either the
entities claiming the marks and names or their products. Dell Inc. disclaims any
proprietary interest in trademarks and trade names other than its own.
February 2011 Rev. A00
Contents | 3
Contents
1 Introduction ................................................................................ 5
BMC Key Features and Functions ............................................................. 5
2 Using the Web UI ....................................................................... 6
Logging in to the Web User Interface ........................................................ 6
Remote Management Controller GUI Explained ....................................... 8
Logout ........................................................................................................ 8
System Information .................................................................................... 8
Server Health ........................................................................................... 10
Configuration ............................................................................................ 12
Remote Control ........................................................................................ 21
Maintenance ............................................................................................. 32
3 Sensors Threshold .................................................................. 37
Contents | 4
4 Events Table ............................................................................. 40
5 IPMI 1.5 / 2.0 Command Support List ..................................... 44
6 IPMI OEM Command List......................................................... 52
Extended Configurations .......................................................................... 61
Appendix ...................................................................................... 71
SSH/Telnet Enable and Disable .............................................................. 71
SSH/Telnet Redirect Enable and Disable ................................................ 72
VLAN ID ................................................................................................... 73
BMC/BIOS Version Info ........................................................................... 74
Introduction | 5
1
Introduction
This section introduces the BMC and includes the requirements for web-based
graphical user interface (GUI), keyboard, video, and mouse (KVM), and virtual
media.
BMC Key Features and Functions
The following lists the supported features of the BMC:
Support for IPMI v1.5 and v2.0
Out-of-band monitoring and control for sever management over LAN
Dedicated 10/100 NIC for remote management over a network
Information which includes main board part number, product name,
manufacturer, and so on.
Health status/hardware monitoring report
View and clear events log.
Event notification using chassis LED indicator and Platform Event Trap
(PET)
Platform Event Filtering (PEF) to take selected action for selected events,
including NMI and SMI
Chassis management including power control and status report, front panel
buttons, LED control, Secure Mode, and Boot Option
Watchdog and auto server re-start and recovery
Multi-session user and alert destination for LAN channel
IPMB connector to enable advanced server management communication
with BMC
Using the WEB UI | 6
2
Using the Web UI
The BMC firmware features an embedded web server, enabling users to connect
to the BMC using an Internet browser (Microsoft Internet Explorer) without
needing to install KVM and virtual storage software on a remote console.
Web-based GUI is supported on the following browsers:
Microsoft Windows:
Internet Explorer 6 or later
Mozilla
®
Firefox
®
2.0017 or later
Linux
:
Mozilla Firefox 2.0017 or later

NOTE:
Before using the web user interface, ensure that the firewall settings are
configured to enable access to the following ports: 7578 (KVM),USB-CDROM:
5120, USB-FLOPPY: 5123.
Logging in to the Web User Interface
Enter the BMC-embedded server IP address or URL into the address bar of the
web browser. The BMC interface has a default of (DHCP\Static). Enter the
system BIOS setup with <F2> to change these settings.
When connecting to the BMC, the login screen prompts for the username and
password. This authentication with Secure Sockets Layer (SSL) protection
prevents unauthorized intruders from gaining access to the BMC web server.
Once authentication is passed, you can manage the server by privilege. At the
same time, the PHP Hypertext Preprocessor (PHP) records all user information,
including user ID and privilege.
U
T
(
t
D
W
p
p
T
U
sing Your
R
T
he Remote
M
(GUI) called t
h
t
o use. It has a
D
efault User
N
W
hen you firs
t
p
rompted to e
n
p
assword for l
o
T
able Error! No
Password
Field
User Name
Password
N
N
a
t
i
R
emote Mana
g
M
anagement C
o
h
e
Remote Ma
n
low learning
c
N
ame and Pa
s
t
try to access
y
n
ter a user na
m
o
gging on to t
h
text of specified
Default
Root
Root
N
OTE:
The defaul
t
N
OTE:
When you l
a
dministrative pow
e
i
me.
g
ement Contr
o
o
ntroller has a
u
n
agement Con
t
c
urve because
i
s
sword
y
our Remote
M
m
e and passwor
d
h
e Remote Ma
n
style in docume
n
t
user name and p
a
og in using the roo
t
e
rs. Change your r
o
U
o
ller:
u
se
r
-friendly
G
t
roller GU
I
. It
i
i
t uses a stand
a
M
anagement C
o
d
. Table 1-1 li
s
n
agement Con
t
n
t.-1. BMC Defa
a
ssword are in low
e
t
user name and p
a
o
ot password after
l
U
sing the WEB UI
G
raphics User
I
i
s designed to
b
a
rd Internet bro
o
ntroller, you
a
s
ts the user na
m
t
roller.
ult User Name
a
er
-case characters.
a
ssword, you have
l
ogging in for the fi
r
| 7
I
nterface
b
e easy
o
wser.
a
re
m
e and
a
nd
r
st
A
g
L
T
C
T
f
T
Using the WEB UI
Remote
M
A
fter you suc
c
g
reeted with t
h
Logout
L
og out from
y
T
he default ti
m
System I
System Infor
m
C
lick the
Syst
e
T
he
System I
n
firmware revi
s
T
able Error! No
BMC Informa
t
System Pow
e
Firmware Re
v
Aux Firmwa
r
Revision
Build Time
| 8
M
anage
m
c
essfully log in
h
e
Remote Ma
n
y
our Remote
M
m
eout value is
3
nformati
o
m
ation
e
m Informati
o
n
formation
ta
b
ion, aux firm
w
text of specified
ion D
e
e
r Status O
n
v
ision R
e
r
e R
e
a
u
D
a
M
m
ent Con
to your Remo
t
n
agement Cont
r
M
anagement C
o
3
0 seconds.
o
n
o
n
tab to view
t
b
enables you t
o
w
are revision,
a
style in docume
n
e
scription
n
or Off
e
mote Manage
m
e
mote Manage
m
u
x revision.
a
te the firmwa
r
M
DD YYYY
troller G
U
t
e Manageme
n
r
oller GU
I
.
o
ntroller
t
he Remote M
a
o
view the Sys
a
nd build time.
n
t.-2. BMC Info
r
m
ent Controll
e
m
ent Controll
e
r
e was last bui
l
HH:MM:SS
U
I Explai
n
t Controller, y
o
a
nagement Co
n
tem Power St
a
r
mation
er
firmware re
v
e
r firmware
l
t in the form:
ned
o
u are
n
troller.
a
tus,
v
ision.
L
T
i
i
C
L
B
L
P
L
N
L
ist FRU
T
he List FRU
p
i
n the system.
i
nformation.
Chassis Infor
m
L
ists the Type
,
B
oard Infor
m
L
ists the Man
u
P
roduct Info
r
L
ists the Man
u
N
umbe
r
.
p
age shows a
l
Select a FRU
i
m
ation
,
Part Number
m
ation
u
facturer, Prod
u
r
mation
u
facturer Nam
e
l
ist of the dete
c
tem from the
d
and the Serial
N
u
ct Name, Ser
i
e
, Product Na
m
U
c
ted Field Repl
d
rop down list
t
N
umber of the
i
al Number an
d
m
e, Serial Num
b
U
sing the WEB UI
aceable Units
(
t
o show more
FRU.
d
Part Number
.
b
er, Version, a
| 9
(
FRUs)
.
a
nd Part
T
S
I
c
c
Using the WEB UI
Server H
T
he
Sensor
m
e
speed, internal
S
ensorRead
i
I
t reads the se
n
category
. Yo
u
c
lick “
Show
T
| 10
ealth
e
nu provides i
n
temperature,
a
i
ngs&Senso
n
sor informati
o
u
can click “
Re
T
hresholds
” to
n
formation ab
o
a
nd voltage.
r
Readings
w
o
n the system.
Y
f
resh
” to re-re
a
show the thre
s
o
ut system har
d
w
ithThreshol
d
Y
ou can
select
a
d the sensor s
s
holds of ever
y
d
ware such as
t
d
s
a sensor type
tate. And you
c
y
sensor.
t
he fan
e
c
an
E
T
m
C
i
t
i
T
c
G
C
E
vent Log
T
he System E
v
m
anaged syst
e
C
ontroller (B
M
i
nformation a
b
t
ype and a sho
r
Select
Server
H
i
nformation.
T
he list can b
e
c
ategories, B
M
G
enerated Ev
e
select. Subseq
u
C
lick
Clear E
v
v
ent Log (SEL
)
e
m. The SEL i
s
M
C) or BIOS o
b
out system ev
e
r
t description.
H
ealth
in me
n
e
sorted by
sele
M
C Generated
E
e
nts, System
M
u
ent selects Ti
m
v
ent Log
to C
l
)
page display
s
generated by
t
n
the manage
d
e
nts: event ID,
n
u bar. Click
E
v
cting any eve
n
E
vents, BIOS
G
M
anagement So
f
m
e Zone. Ther
l
ear the SEL.
U
s
s
system event
s
t
he Baseboard
d
system. The
S
time stamp, s
e
v
ent Log
to vi
e
n
t log categor
y
G
enerated Eve
n
f
tware Events,
e
are two opti
o
s
ing the WEB UI
s
that occur on
Management
S
EL lists the fo
e
nsor name, se
n
e
w specific ev
e
y
. There are si
x
n
ts, SMI Hand
l
and Unknow
n
o
ns, Local and
| 11
the
o
llowing
n
sor
e
nt
x
ler, FCB
n
you can
GMT.
A
W
c
T
a
T
Using the WEB UI
Configu
r
A
lerts
W
hen the BM
C
c
omponent fai
l
T
he
Alerts
wi
n
a
ctivate the al
e
T
o set up a de
s
1
Click a
n
| 12
r
ation
C
senses a plat
l
ure, an alert
m
n
dow enables
y
e
rts for each a
d
s
tination to rec
e
n
Alert Numb
form event, su
c
m
essage can be
y
ou to enter e
m
d
dress.
e
ive alerts, pe
r
er
, click
Mod
i
c
h as an envir
o
sent to one or
m
m
ail addresses,
r
form the follo
w
i
fy
.
o
nmental warn
i
m
ore email ad
d
IP addresses,
a
w
ing
p
rocedur
e
i
ng or a
d
resses.
a
nd to
e
U
s
s
ing the WEB UI
| 13
Using the WEB UI
2
Select
A
3
Select
E
Inform
a
4
If your
| 14
A
lert Type
, th
e
E
vent Severit
y
a
tional, Warni
n
Alert Type
is
e
re are two op
t
y
, The five opt
i
n
g, Critical an
d
Snmp Trap, ty
p
t
ions,
Snmp T
r
i
ons available
a
d
Non-recover
a
p
e the destinat
r
ap and Emai
l
a
re, Disable Al
a
ble.
ion IP.
l
.
l
l,
5
If your
enter a
b
6
Click
S
Alert Type
is
b
rief descripti
o
ave
.
Email, enter t
h
o
n for the
Sub
j
U
s
h
e destination
e
j
ect
of the em
a
s
ing the WEB UI
e
mail address,
a
il.
| 15
a
nd
M
I
m
A
R
N
D
Using the WEB UI
M
ouse mode
I
t is an option
t
m
ode depends
A
bsolute
mod
R
elative
mod
e
N
etwork
Show the Re
m
D
HCP or ST
A
| 16
t
o set up mous
on OS can ge
t
e for host’s sy
s
e
for host’s sys
t
m
ote Managem
e
A
TIC IP then cl
e mode which
t
accurate mou
s
s
tem is Windo
w
t
em is Linux
O
e
nt Controller
I
i
ck “
Save
”.
will using in
K
s
e pointer.
w
s OS
O
S.
I
P address info
K
VM. Setting
m
rmation. You
c
m
ouse
c
an set
c
SMTP
Set E-mail (S
M
c
lick “
Save
”.
M
TP) server IP address for se
n
U
s
n
ding alert no
t
s
ing the WEB UI
t
ification to us
e
| 17
e
r then
U
T
u
a
T
T
T
U
T
Using the WEB UI
U
sers
T
he
Users
p
a
g
u
sers. You ca
n
a
ccessing priv
i
T
able 1-28 dis
p
T
able Error! No
BMC Informa
t
User ID
User Name
Network Pri
v
T
here are thre
e
U
ser.
T
o add new u
s
| 18
g
e enables you
t
n
control user
w
i
leges.
p
lays the
User
text of specified
ion
v
ilege
e
operations in
er, click their
u
t
o view infor
m
w
ho can login
R
s
list for existi
n
style in docume
n
Description
Displays a se
q
Displays the
l
Displays the
g
the user is as
s
User, Custo
m
Users
p
age:
A
u
ser ID numb
m
ation and con
f
R
emote Mana
g
n
g BMC users
.
n
t.-3. BMC Use
r
q
uential user I
D
l
ogin name of
t
g
roup (privile
g
s
igned. (Admi
n
m
, or None).
A
dd User, Mod
i
e
r
, in the
Use
r
f
igure existing
g
ement Control
.
r
Information
D
number.
t
he user.
g
e level) to wh
i
n
istrator, Oper
a
i
fy User and D
r
s
list. Click
A
d
BMC
l
ler and
i
ch
a
tor,
elete
d
d User
.
E
p
E
nter user na
m
p
rivileges, cli
c
m
e, IPMI versi
o
c
k
Add
.
o
n, password,
c
U
s
c
onfirm passw
o
s
ing the WEB UI
o
rd and netwo
r
| 19
r
k
T
C
M
p
T
U
r
Using the WEB UI
T
o change the
C
lick
Modify
U
M
odify user n
a
p
rivileges, cli
c
T
o delete new
U
ser
. A dialo
g
r
efresh page.
N
o
| 20
settings for a
u
U
ser
.
a
me, IPMI ver
s
c
k
Modify
.
user, click the
i
g
box appears
,
c
N
OTE:
You must
h
o
therwise these op
t
u
ser, click thei
r
s
ion, passwor
d
i
r
user ID nu
m
c
lick
yes
to de
l
h
ave Configure Us
e
t
ions are not availa
b
r
user ID num
d
, confirm pass
w
m
ber
, in the
U
s
l
ete the user a
n
e
rs permission to c
o
b
le
b
er
, in the
Us
e
w
ord and net
w
s
ers
list. Click
n
d automatical
l
o
nfigure a BMC us
e
e
rs
list.
w
ork
Delete
l
y
e
r;
/