LCI Taylor Made AquaFi 781414 Installation and Owner's Manual

  • Hello! I am an AI chatbot trained to assist you with the LCI Taylor Made AquaFi 781414 Installation and Owner's Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
1
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
T ab le of C ontents
Introduction ............................................ 1
S afety ................................................... 1
P arts L ist ................................................ 2
R esources R eq uired ................................... 2
Installation .............................................. 2
Activ ation ............................................... 4
S ystem Requiremen ts ................................. 4
P reparation ............................................ 4
A quaF i S ystem A ctivation ............................. 5
Con n ectin g to th e H otspot ............................. 5
C h ang ing N etwork N ame and P assword ............. 6
Mob ile U se .............................................. 8
T roub lesh ooting ........................................ 9
Maintenance ............................................ 9
FC C C ompliance . ..................................... 10
F CC 15B statemen t .................................. 10
F CC P art 15 complian ce statemen t . ................. 10
I C U ser man ual n otice ............................... 10
RF E x posure S tatemen t ............................. 10
W iring D iag rams ..................................... 11
W atercraft ........................................... 11
N otes .................................................. 12
AquaFi
TM
Installation and
Owners Manual
(For Aftermarket Applications)
Aq uaFi
T M
K it
P art # D escription
781414 A quaF i
T M
H otspot
Introduction
T h e T aylor M ade
®
A quaF i
H otspot provides b oatin g
en th usiasts w ith w ireless I n tern et con n ectivity. A secure
2.4 G H z W iF i n etw ork con n ects devices to th e I n tern et
at 4G L T E speeds up to 150 M b ps. A ll an ten n ae are fully
con tain ed for a splash -proof solution . T h e 12V DC pow er is
sourced th roug h a moun tin g dock w ith sn ap-in portab ility.
T h e A quaF i
H otspot can b e removed from its moun tin g
dock an d operated on -sh ore utiliz in g an in cluded A C-to-
DC w all plug pow er supply. T h e S I M card slot an d pow er
port are accessib le b y removin g th e side compartmen t
cover. Compatib le w ith 4G L T E B an ds 2, 4 an d 12.
A ddition al in formation ab out th is product can b e ob tain ed
from taylormadeproducts.com/aquafi.
N OT E : A quaF i H otspot screen imag es are from an iO S
mob ile device. S creen imag es from an A n droid mob ile
device may appear slig h tly differen t.
S afety
Read an d fully un derstan d all in struction s b efore in stallin g
or operatin g th is product. A dh ere to all safety lab els.
T h is man ual provides g en eral in struction s. M an y variab les
can ch an g e th e circumstan ces of th e in struction s, i.e., th e
deg ree of difficulty, operation an d ab ility of th e in dividual
performin g th e in struction s. T h is man ual can n ot b eg in to
plot out in struction s for every possib ility, b ut provides
2
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
Aq uaFi K it7 8 1 4 1 4
L etter P N D escription Q ty
A 781411 A quaF i H otspot A ssemb ly 1
B 781413 A quaF i H otspot Dock A ssemb ly 1
C 722253 120V A C/DC P ow er S upply 1
th e g en eral in struction s, as n ecessary, for effectively
in terfacin g w ith th e device, product or system. F ailure to
correctly follow th e provided in struction s may result in death ,
serious person al in j ury, severe product an d/or property
damag e, in cludin g voidin g of th e L CI limited w arran ty.
P h illips screw driver
H eat g un
H eat sh rin k tub in g
F our # 8 pan h ead screw s
T w o b utt con n ectors
W ire crimpers
W ire strippers
18 A W G pow er an d g roun d
w ire ( depen din g on location
of in stallation related to
pow er source)
T H E C AU T ION S Y MB OL AB OV E IS A S IG N
T H AT AN IN S T AL L AT ION P R OC E D U R E H AS
A S AFE T Y R IS K IN V OL V E D AN D MAY C AU S E
P E R S ON AL IN J U R Y OR P R OD U C T D AMAG E IF
N OT P E R FOR ME D S AFE L Y AN D W IT H IN T H E
P AR AME T E R S S E T FOR T H IN T H IS MAN U AL .
T H E W AR N IN G S Y MB OL AB OV E IS A S IG N T H AT
AN IN S T AL L AT ION P R OC E D U R E H AS A S AFE T Y
R IS K IN V OL V E D AN D MAY C AU S E D E AT H OR
S E R IOU S P E R S ON AL IN J U R Y , S E V E R E P R OD U C T
OR P R OP E R T Y D AMAG E IF N OT P E R FOR ME D
S AFE L Y AN D W IT H IN T H E P AR AME T E R S S E T
FOR T H IN T H IS MAN U AL .
Fig.1
P arts L ist
N OT E : P art n umb ers are sh ow n for iden tification purposes
on ly. N ot all parts are availab le for in dividual sale. A ll parts
w ith a lin k to th e T aylor M ade S tore can b e purch ased.
R esources R eq uired
Installation
1 . M ak e sure w atercraft is dry-dock ed or oth erw ise
supported ab ove w ater to avoid an un stab le con dition
created b y w aves.
2 . L ocate a moun tin g area th at allow s con n ection of th e
A quaF i H otspot Dock A ssemb ly’s pow er an d g roun d w ires
to th e w atercraft’s pow er source w ith out creatin g a strain
on th e completed con n ection .
N OT E : V ertical orien tation of product at in stallation is required.
N OT E : T h e moun tin g dock sh ould b e easily accessib le
w ith en oug h room to remove th e A quaF i H otspot A ssemb ly
from its dock .
3 . I f n ecessary, remove th e A quaF i H otspot (Fig.2A) from its
moun tin g dock (Fig.2B) an d set aside for later use.
A. S lig h tly lift an d h old th e top clampin g tab .
B . P ivot th e h otspot un it forw ard an d release th e
clampin g tab .
4 . Con n ect th e moun tin g dock s red pow er (Fig.3A) an d
b lack g roun d (Fig.3B) electrical w ires to th e appropriate
w ires of th e w atercraft’s pow er system w ith crimp-style b utt
con n ectors (Fig.3C).
A
B
C
3
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
Fig.2
A. I f n ecessary, use w ire strippers to ex pose en oug h
b are w ire to mak e a g ood electrical con n ection w ith in th e
b utt con n ector.
B . Cut a 1
½ lon g strip of h eat sh rin k tub in g . S lip tub in g
on to electrical w ire.
Fig.3
A
B
C . I n sert th e dock in g w ire in to on e open en d of th e b utt
con n ector, th en crimp b utt con n ector in -place usin g a
crimpin g tool.
D . I n sert 12V DC electrical system w ire in to th e
remain in g open en d of th e b utt con n ector. Crimp b utt
con n ector in -place.
E . S lide h eat sh rin k tub in g over th e con n ection . A pply
h eat g un to th e tub in g . to seal th e con n ection .
F. I f usin g h eat sh rin k /crimp b utt con n ectors, addition al
h eat sh rin k tub in g is n ot required. Do as follow s:
I. I n sert w ire in to b utt con n ector.
II. Crimp b utt con n ector.
III. Repeat steps I an d I I on th e oth er con n ector en d.
IV . U se a h eat g un on th e b utt con n ector to seal it
ag ain st th e electrical w ires.
N OT E : M ak e sure th e electrical con n ection s are secure
an d protected ag ain st w ater.
5 . S ecure th e A quaF i H otspot Dock A ssemb ly to th e
w atercraft w ith four # 8 pan h ead screw s (Fig.4A).
Fig.4
A
to watercraft
1 2 V D C power
C
A
B
N OT E : M oun tin g dock electrical w ires (Fig.3A and B) are
6 lon g .
4
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
App Store
®
is a trademark of Apple Inc.
Android
TM
and Google Play
TM
are trademarks of Google LLC.
A pp S tore
Fig.5
Activ ation
A data packa g e is required to activate th e A quaF i w ireless
I n tern et system. G o to taylormadeproducts.com/aquafi for
data plan activation . H ave th e I M E I ( I n tern ation al M ob ile
E quipmen t I den tity) n umb er, M ak e an d M odel of th e
w atercraft an d a credit card availab le.
T h e I M E I n umb er is on th e product lab el located on th e
b ack side of th e A quaF i H otspot A ssemb ly.
S y stem R eq uirements
Data packa g e
A n droid or iO S smart device
A quaF i app
P reparation
A quaF i system activation requires th e A quaF i app in stalled
on a smart ph on e, or oth er smart device.
1 . Dow n load th e A quaF i app (Fig.5) from eith er A pple’s A pp
S tore ( iO S ) or G oog le P lay ( A n droid) .
2 . I n stall th e A quaF i app on to th e smart device.
3 . G o to W i-F i settin g s on th e mob ile device (Fig.6), th en
select th e h otspot’s A quaF i S S I D (Fig.6A) from th e list of
availab le w ireless n etw ork s.
4 . M ak e sure th e selected n etw ork n ame (Fig.6A) match es
th e S S I D n ame located on th e b ack side of th e A quaF i
H otspot A ssemb ly (Fig. 7A).
A
Fig.6
Fig.7
A
B
5
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
5 . L aun ch th e A quaF i app.
6 . E n ter th e U sern ame an d P assw ord (Fig.8A) prin ted on
th e product lab el (Fig.7B).
7 . A fter en terin g th e log in creden tials, tap th e L og in
b utton (Fg.8B).
Aq uaFi S y stem Activ ation
A ctivation of th e A quaF i H otspot system can b e performed
on sh ore or on a w atercraft.
I f activatin g th e system on sh ore, th e 120V A C/DC
pow er supply (Fig.1C) is required. Refer to th e O n S h ore
U se section .
1 . M ak e sure w atercraft is dry-dock ed or oth erw ise
supported ab ove w ater to avoid an un stab le con dition
created b y w aves.
2 . M ak e sure th e A quaF i H otspot is securely seated in its
moun tin g dock . T h e dock sh ould sn ap on to th e h otspot.
N OT E : A secured A quaF i H otspot w ill mak e g ood
electrical con n ection s across th e moun tin g dock an d
h otspot matin g con tact pin s.
3 . T urn system pow er on .
4 . A ll L E Ds sh ould lig h t up (Fig.9A).
N OT E : T h e L E Ds w ill flash b lue as th e A quaF i system
b oots up, th en g reen in a steady state w h en th e system
con n ects to 3G /4G L T E .
Fig.8
B
A
A
N OT E : I f L E Ds are red, th is in dicates on e of th e
follow in g con dition s ex ists: n o service, n o S I M card or a
2G less con n ection .
C onnecting to th e H otspot
1 . A fter a successful con n ection h as b een estab lish ed, g o
to W i-F i settin g s on th e mob ile device (Fig.10A), th en select
th e h otspots A quaF i S S I D (Fig.11A) from th e list of availab le
w ireless n etw ork s.
Fig.9
Fig.10
A
2 . W h en prompted, en ter th e usern ame an d passw ord
(Fig.12A) located on th e product lab el (Fig.7B).
3 . A fter log in creden tials h ave b een en tered (Fig.13A), press
th e L og in b utton (Fig.13B).
4 . T h e A quaF i H ome screen w ill display sh ow in g
S E T T I N G S (Fig.14A) an d B A N DW I DT H (Fig.14B) option s.
6
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
A
Fig.12
Fig.13
Fig.14
C h ang ing N etwork N ame and
P assword
1 . F rom an estab lish ed n etw ork con n ection , th e S ettin g s
screen (Fig.15) sh ow s th ree option s:
A. S S I DCh an g e W iF i S S I D an d P assw ord (Fig.15A)
B . L og in Ch an g e admin istrator passw ord (Fig.15B)
A
Fig.11
B
A
A
B
7
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
C . A dvan cedV iew an d update advan ced settin g s (Fig.15C)
Fig.15
A
B
C
N OT E : T h e S S I D is th e n etw ork n ame an d P assw ord
is used to con n ect to th e h otspot. T h e L og in ch an g es
th e admin istrator passw ord used to access th e mob ile
appA quaF i. T h e A dvan ced settin g s allow s view in g an d
updatin g of select advan ced settin g s.
2 . T o ch an g e th e W iF i S S I D n ame, tap th e rig h t b rack et (
>)
to display th e Ch an g e W iF i I n fo screen (Fig.16).
3 . H ig h lig h t th e curren t S S I D n ame (Fig.16A), th en type in
th e n ew n ame.
4 . Next, select the Password eld (Fig.16B) an d en ter a n ew
passw ord for th e n ew W iF i S S I D.
5 . P ress th e E n ter b utton (Fig.16C) to apply th e ch an g es or
Can cel (Fig.16D) to retain default settin g s.
6 . I f th e E n ter b utton w as pressed, th e S uccess screen
(Fig.17) w ill display.
7 . P ress th e OK b utton (Fig.17A) to reb oot th e h otspot an d
login to the recongured system with the new credentials.
8 . G o to th e device’s W iF i settin g s an d select th e n ew
S S I D n etw ork n ame (Fig.18A).
9 . E n ter th e passw ord for th e n ew S S I D n etw ork (Fig.19A).
1 0 . T o ch an g e th e L og in admin istrator passw ord, g o to th e
A quaF i H ome S ettin g s screen (Fig.15) an d select th e L og in
option (Fig.15B).
Fig.16
A
B
C
D
A
Fig.17
8
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
1 1 . T ap th e rig h t b rack et ( >) to display th e Ch an g e A dmin
P assw ord screen (Fig.20).
1 2 . Select the New Password eld (Fig.20A) an d en ter
a n ew admin istrator passw ord, th en select th e N ew
Password Again eld (Fig.20B) an d re-en ter th e n ew
admin istrator passw ord.
1 3 . P ress th e E n ter b utton (Fig.20C) to apply th e ch an g es
or Can cel (Fig.20D) to retain default settin g s.
1 4 . T o recon n ect, g o to W i-F i settin g s on th e mob ile device,
th en w h en prompted, en ter th e n ew log in creden tials.
Fig.18
A
A
Fig.19
Fig.20
A
B
C
D
On S h ore U se
T o use th e A quaF i H otspot on sh ore, do as follow s:
1 . Remove th e h otspot un it from its moun tin g dock (Fig.2).
A. S lig h tly lift an d h old th e top clampin g tab .
B . P ivot th e h otspot un it forw ard an d release th e
clampin g tab .
2 . T ak e th e h otspot an d th e 120V A C/DC pow er supply
(Fig.1C) to a sh ore-b ased 120V w all outlet.
9
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
5 . I n sert th e pow er supplys b arrel con n ector in to th e
h otspots pow er supply port (Fig.22A).
6 . P lug th e 120V A C/DC pow er supply (Fig.22B) in to a w all
outlet (Fig.22C).
7 . G o to th e mob ile device’s W iF i settin g s.
A. S elect th e A quaF i n etw ork .
B . E n ter log in creden tials to recon n ect to th e
A quaF i n etw ork .
3 . Remove th e access door (Fig.21A) b y un screw in g th e tw o
P h illips pan h ead screw s (Fig.21B).
4 . S et th e screw s an d access door aside for later in stallation .
R E MOV AL OF AC C E S S D OOR E X P OS E S IN T E R N AL
C OMP ON E N T S T O C ON T AMIN AT ION B Y W AT E R .
W AT E R C ON T AMIN AT ION C AN S E R IOU S L Y
D AMAG E IN T E R N AL E L E C T R IC AL C OMP ON E N T S ,
R E N D E R IN G T H E U N IT IN OP E R AB L E . U S E C AR E
W H E N OP E R AT IN G T H E U N IT W H IL E P R OT E C T IV E
AC C E S S D OOR IS R E MOV E D .
A
B
B
Fig.21
A
C
B
Fig.22
T roub lesh ooting
M ost con cern s w ith th e A quaF i H otspot can b e diag n osed
b y ch eck in g th e in dicator lig h ts ( L E Ds) located on th e fron t
of th e un it (Fig.9A). Refer to th e follow in g L E D S tatus Ch art
w h en troub lesh ootin g .
Maintenance
P eriodically ch eck moun tin g dock for crack ed or missin g
clampin g tab an d cradle h ook s. Replace dock , if n ecessary.
T urn off pow er to th e A quaF i system. Remove th e h otspot
from its dock . S eparately, w ipe th e un it an d dock w ith a
fresh -w ater dampen ed cloth . M ak e sure b oth compon en ts,
an d th eir electrical con tacts, are completely dry b efore
reattach in g th e h otspot to th e moun tin g dock .
Clean system w ith fresh -w ater dampen ed cloth s after each
use in salt w ater en viron men ts.
Remove th e A quaF i H otspot from its moun tin g dock w h en
w atercraft is n ot in use or in storag e. K eep h otspot in a dry,
cool location w h en n ot b ein g used on w atercraft.
E n viron men t
O peratin g T emperature 32 ° F ~ 131 ° F
S torag e T emperature -40 ° F ~ 158 ° F
O peratin g H umidity 10% ~ 90%
S torag e H umidity 5% ~ 95%
1 0
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
FC C C ompliance
FC C 1 5 B statement
T h is equipmen t h as b een tested an d foun d to comply w ith th e
limits for a Class B dig ital device, pursuan t to part 15 of th e
F CC Rules. T h ese limits are desig n ed to provide reason ab le
protection ag ain st h armful in terferen ce in a residen tial
in stallation . T h is equipmen t g en erates, uses an d can radiate
radio frequen cy en erg y an d, if n ot in stalled an d used in
accordan ce w ith th e in struction s, may cause h armful in terferen ce
to radio commun ication s. H ow ever, th ere is n o g uaran tee th at
in terferen ce w ill n ot occur in a particular in stallation . I f th is
equipmen t does cause h armful in terferen ce to radio or television
reception , w h ich can b e determin ed b y turn in g th e equipmen t off
an d on , th e user is en courag ed to try to correct th e in terferen ce
b y on e or more of th e follow in g measures:
Reorien t or relocate th e receivin g an ten n a.
I n crease th e separation b etw een th e equipmen t
an d receiver.
Con n ect th e equipmen t in to an outlet on a circuit differen t from
th at to w h ich th e receiver is con n ected.
Con sult th e dealer or an ex perien ced radio/T V tech n ician for h elp.
FC C P art 1 5 compliance statement
T h is device complies w ith part 15 of th e F CC Rules.
L E D S tatus C h art
L E D C olor W h at is h appening ? W h y ? W h at sh ould b e done?
B lue S ystem is b ootin g up. S ystem w as off. N oth in g . T h is is n ormal.
G reen S uccessful n etw ork con n ection .
N o previous n etw ork
con n ection .
N oth in g . T h is is n ormal.
Red
N o service.
O ut of carrier’ s service
coverag e area.
Relocate w ith in carrier’ s coverag e area.
N o S I M card. M issin g or damag ed S I M card. Replace S I M card.
2G or less con n ection . W eak service area. Relocate w ith in a stron g er service area.
I n correct A P N in formation .
A ccess P oin t N ame ( A P N ) h as
b een ch an g ed or b locke d.
Con tact T aylor M ade P roducts.
N o color N o pow er.
H otspot n ot fully seated in its
moun tin g dock .
Remove h otspot from moun tin g dock, th en
rein sert in to dock .
M ake sure h otspot an d dock clamps are fully
en g ag ed, creatin g a g ood electrical con n ection .
M ain pow er off. T urn main pow er on .
O b struction b etw een electrical
con tacts.
Clear an y ob struction from b etw een th e
moun tin g dock an d h otspot electrical con tacts.
O peration is sub j ect to th e follow in g tw o con dition s:
( 1) T h is device may n ot cause h armful in terferen ce, an d
( 2) th is device must accept an y in terferen ce received,
in cludin g in terferen ce th at may cause un desired operation .
IC U ser manual notice
T h is device con tain s licen se-ex empt tran smitter( s) /receiver( s)
th at comply w ith I n n ovation , S cien ce an d E con omic
Developmen t Can ada’s licen se-ex empt RS S ( s) . O peration is
sub j ect to th e follow in g tw o con dition s:
T h is device may n ot cause in terferen ce.
T h is device must accept an y in terferen ce, in cludin g
in terferen ce th at may cause un desired operation
of th e device.
N on- modification W arning
A n y ch an g es or modification s to th is device n ot ex pressly
approved b y th e party respon sib le for complian ce could void th e
users auth ority to operate th is equipmen t.
R F E x posure S tatement
T h is equipmen t complies w ith F CC/I C radiation ex posure
limits set forth for an un con trolled en viron men t an d meets
th e F CC radio frequen cy ( RF ) E x posure G uidelin es an d
RS S -102 of th e I C radio frequen cy ( RF ) E x posure rules.
T h is equipmen t sh ould b e in stalled an d operated k eepin g
th e radiator at least 30cm or more aw ay from person s b ody.
1 1
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
W iring D iag rams
W atercraft
On S h ore
aq uafi h otspot
aq uafi mounting dock
power
g round
connect aq uafi mounting
dock to watercraft 1 2 V D C
electrical sy stem
watercraft
b utt connectors
aq uafi h otspot
1 2 V D C
power port
1 2 0 V AC / D C
power supply
1 1 0 V AC
wall outlet
1 2
taylormadeproducts.com/aquafi 574-534-7521 aquafisupport@lci1.com Rev:08.01.19
AquaFi
Installation and Owners Manual
(For Aftermarket Applications)
CCD-0002558
M an ual in formation may b e distrib uted as a complete
documen t on ly, un less T aylor M ade P roducts provides
ex plicit con sen t to distrib ute in dividual parts.
A ll man ual in formation is sub j ect to ch an g e w ith out
n otice. Revised edition s w ill b e availab le for free
dow n load at taylormadeproducts.com/aquafi. M an ual
in formation is con sidered factual un til made ob solete b y
a revised version .
P lease recycle all ob solete materials an d con tact T aylor
M ade P roducts w ith con cern s or question s.
N otes
/