AP-AC-MLX-EX AC Connector Kit
Installation Guide
0512260-02 | March 2022 1
Package Contents
Housing x1
Crimp terminals x 6
20A2F cable gland x 1
AC extension tube x 1
AP-AC-MLX-EX installation guide
Customer Supplied Equipment
UV-resistant, outdoor-rated three-wire AC cable (18 AWG) with outside cable diameter of 6-12mm
and inside wire diameter no more than 3.1mm
Wire stripper
Crimp tool
Extraction tool (for removing terminals from housing)
Sliding Cable Gland over AC Power Cable
1. Remove the cap on the AC power port.
2. Slide the sealing nut, seal A, seal B, gland body, O-ring and AC extension tube over the cable. See Figure 1.
Figure 1 AC Power Cable, AC Extension Tube and 20A2F Cable Gland
Only three crimp terminals are needed to assemble the AC connector. We include 6 crimp terminals in the
package in case the crimp terminals are damaged during assembly.
The opening of the gland is smaller than the AC housing, so you need to slide the sealing nut, seal A, seal B,
gland body, O-ring and AC extension tube over the AC cable before assembling the AC housing on the cable.
AC Cable
O-ring
Gland Body
Seal B Seal A
Sealing Nut
AC Extension Tube