SunPower Type E Flexible 100 watt 12 Volt Solar Panel User manual

Type
User manual
SafetyandInstallationInstructionsfor
SunPowerTypeE,TypeGandTypeHACModules
UnitedStatesandCanada
Contentsaresubjecttochangewithoutnotice.
Forthelatestversionvisitwww.sunpower.maxeon.com/int/PVInstallGuideULAC
SunPowerCorporation
www.sunpower.com
531725RevJ
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
SafetyandInstallationInstructionsforACModules
IMPORTANTSAFETYINSTRUCTIONS
SAVETHESEINSTRUCTIONS
1.0 Introduction
ThisdocumentprovidessafetyandinstallationinstructionsfortheUL
ListedSunPowerACphotovoltaic(PV)modulesdescribedherein,allof
whichbeartheULlogoontheproductlabel:
1.1DisclaimerofLiability
Theinstallationtechniques,handlinganduseofthisproductarebeyondcompany
control.Therefore,SunPowerdoesnotassumeresponsibilityforloss,damage,or
expenseresultingfromimproperinstallation,handling,oruse.
1.2NationallyRecognizedTestingLaboratory(NRTL)Listing
Information
ThisproductmeetsorexceedstherequirementssetforthbyUL1703orUL61730,
UL1741andUL1741SAforACPVModules.TheUL1703Standardcoversflat
platePVmodulesintendedforinstallationonbuildings;orthoseintendedtobe
freestanding.TheUL1741SAStandardcoversinverters,converters,controllers,
andinterconnectionsystemequipmentforusewithdistributedenergyresources,
includingACmodules.TheNRTLlistingdoesnotincludeintegrationintoabuilding
surfacebecauseadditionalrequirementsmayapply.Thisproductisnotintended
forusewhereartificiallyconcentratedsunlightisappliedtothemodule.TheType
EandtheTypeGACmodulemodelscomplywithHECORule14H,CACPUCRule
21,15472003and1547a2014.
1.3LimitedWarranty
ModulelimitedwarrantiesaredescribedinfullintheSunPowerwarranty
certificatesobtainableatwww.sunpower.com.Insummary,theLimited
Warrantiesdonotapplytoanyofthefollowing:
PVmoduleswhichinSunPower'sabsolutejudgmenthavebeensubjectedto:
misuse,abuse,neglect,oraccident;alteration,improperinstallation,application,
orremoval.Including,butnotlimitedtoinstallation,application,orremovalby
anypartyotherthanaSunPowerauthorizedDealer;nonobservanceof
SunPower'sinstallation,user’sand/ormaintenanceinstructions;repairor
modificationsbysomeoneotherthananapprovedservicetechnicianof
SunPower;powerfailuresurges,lightning,flood,fire,accidentalbreakageorother
eventsoutsideSunPower'scontrol.
2.0 SafetyPrecautions
Beforeinstallingthisdevice,readallsafetyinstructionsinthisdocument.
DisconnecttheutilityACsourcefromallmodulesinthearraybeforemaking
orbreakingelectricalconnections.
UseonlytheAClockingconnectorsinordertodefendagainstuntrained
personneldisconnectingthemodulesaftertheyhavebeeninstalled.
AllinstallationsmustbeperformedincompliancewiththeNationalElectrical
Code(NEC)andanyapplicablelocalcodes.
Installationshouldbeperformedonlybyqualifiedpersonnel.
Removeallmetallicjewelrypriortoinstallingthisproducttoreducethe
chanceofaccidentalexposuretolivecircuits.
Useonlyinsulatedtoolstoreduceyourriskofelectricshock.
Donotstandon,drop,scratch,orallowobjectstofallonmodules.
Brokenglass,Jboxes,brokenconnectors,and/ordamagedbacksheetsare
electricalhazardsaswellaslacerationhazards.Ifamoduleiscrackedafter
installation,aqualifiedpersonshouldremovethemodulefromthearrayand
contactthesupplierfordisposalinstructions.
Donotinstallorhandlemoduleswhentheyarewetorduringperiodsofhigh
wind.
Unconnectedconnectorsmustalwaysbeprotectedfrompollution(e.g.dust,
humidity,foreignparticles,etc),priortoinstallation.Donotleave
unconnected(unprotected)connectorsexposedtotheenvironment.Aclean
installationenvironmentisessentialinordertoavoidperformance
degradation.
Donotblockdrainholesorallowwatertopoolinornearmoduleframes
Contactyourmodulesupplierifmaintenanceisnecessary.
Savetheseinstructions!
3.0 ElectricalCharacteristics
AllelectricalcharacteristicsandgridinteractiondataareshowninSection7.Itis
theinstaller’sresponsibilitytosetthegridprofile—thiscanonlybedonewith
internetaccessandtheSunPowermonitoringsystem.
IfaninstallationinvolvesaSunPowerACmodulewhichdoesnotappearonthis
listpleaseconsulttheproductlabelonthebackofthemoduleorvisit
www.sunpower.comfortheproductdatasheet.
3.1FireRating
TheACmodulemaintainsthesameType2fireratingassociatedwithDC
modules.
4.0 ElectricalConnections
ModulesmustonlybeconnectedusingthesuppliedACcablingandintegrated
connectors.Donotalteranyconnectors.PlugandSocketconnectorsmated
togetherinaPVsystemmustbeofthesametype(model,rating)fromthesame
manufactureri.e.aplugconnectorfromonemanufacturerandasocketconnector
fromanothermanufacturer,orviceversa,shallnotbeusedtomakeaconnection.
Ensurethatthecablingisnotundermechanicalstress(complywithbendingradius
of≥60mm)andmustnotbebentonthedirectexitoftheconnectororjunction
box.TheACmodulecablesystemfeatureslockingconnectorswhich,after
connected,requiretheuseofatooltodisconnect.Thisdefendsagainstuntrained
personneldisconnectingthemoduleswhenunderload.ACcableconnectorsare
ratedandtestedtointerruptloadcurrent;however,SunPowerrecommendsthat
youalwaysopentheutilitydedicatedbranchcircuitprotectortoremovepower
beforepluggingorunplugginganyconnectors;butalocalACdisconnectisnot
requiredbySunPower.
WheninstallingACmodulestheNationalElectricCode,ANSI/NFPA70wiring
methodsshallbeused.
4.1EquipmentGrounding
Toreducethepossibilityofelectricalshock,groundthemoduleframeorarray
perNECbeforewiringthecircuit.InordertoinstallinaccordancewiththeirUL
Listing,SunPowerACmodulesmustbegroundedusingListedgrounding
hardwarethatmeetsrequirementsforgroundingsystemsinUL467,UL1703,UL
1741,orUL2703;onanodizedaluminumframes.SunPowerrecommendsusing
oneofthefollowingmethodsofgroundingthemoduleframe.ASeries‐BLK
modulesmustbeinstalledwiththeGroundLugAssemblyoftheInvisimount
mountingsystemusingtheIlscoGBL4DBTgroundinglugtightenedtoatorqueof
85inlbstobondthemoduleframetotherail.Inaddition,toavoidcorrosiondue
totheuseofdissimilarmetalsSunPowerrecommendsstainlesssteelbetween
copperandaluminum.
Important!Pleasereadtheseinstructionsintheirentiretybefore
installing,wiring,orusingthisproductinanyway.Failuretocomply
withtheseinstructionswillinvalidatetheSunPowerLimited
WarrantyforPVModules.
Danger
!
ACmodulesgenerateinternaldirectcurrent(DC)andoutput
alternatingcurrent(AC);andareasourceofvoltagewhenunderloadand
whenexposedtolight.Electricalcurrentscanarcacrossgapsandmay
causeinjuryordeathifimproperconnectionordisconnectionismade;orif
contactismadewithmoduleleadsthatarefrayedortorn.
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
1) ModulesmaybegroundedthroughtheuseofanInvisiMount™midclamp
thatbondsthemoduleframetotheInvisiMountrail.ThismethodisUL
2703Listed.InvisiMountrailsectionsmustbebondedandconnectedtoa
groundingconductorusingmethodsandmaterialsspecifiedinthe
InvisiMountResidentialMountingSystemInstallationGuide508988.
2) Modulesmaybegroundedbyattachingalayinlug(IlscoGBL4DBT,Burndy
CL50DBTorTycoSolklip19543812)tooneofthegroundingholesonthe
moduleframe,andattachthegroundconductortothelug.Usestainless
steelhardware(bolt,washers,andnut).Useanexternaltoothstarwasher
betweenthelugandthemoduleframeinordertopiercetheanodizingand
establishelectricalcontactwiththealuminumframe.Theassemblymust
endwithanutthat’storquedto20–25inlb(fora#1032bolt).Alock
washerorotherlockingmechanismisrequiredtomaintaintension
betweentheboltandtheassembly.Theconductormustbeattachedtothe
groundlugusingthelug’ssetscrew.RefertoNEC690.
Note:Method3isevaluatedtoUL1703byETL.Assuch,theuseofthesedevices
isnotconsideredpartoftheULListingofthesemodules.
3) IftheUniracSOLARMOUNTsystemisused,modulesmaybegroundedby
usingeitheraBURNDYWileyWEEBUMCorWEEBUGC1groundingclipin
combinationwithUniracMidorEndclampsand1/420boltandflanged
nut,torquedto120inlbs.IftheSolarmountIsystemisusedgroundingis
achievedwiththeUniracUGC2groundingclipsincombinationwithUnirac
MidorEndclampsandSliderswitha1/420boltandflangednuttorquedto
120inlbs.
Note:Method4wasevaluatedtoUL2703byTUV.Assuch,theuseofthese
devicesisnotconsideredpartoftheULListingofthesemodules.
4) ModulesmaybegroundedusingaWEEB9.5NLgroundclipbetweenthe
moduleandsupportingstructure.Thiscombinationissecuredwitha1/4″
stainlesssteelrivetora1/420×3/4″zincplatedboltwithzincplatedKnut
torquedtomin.6ftlbstosecurethemoduletominimum12ga.G90
coatedsteelorZpurlin,eitherpaintedorunpainted.TheWEEB9.5NLisfor
singleuseonly.
5) Othergroundingmethodsmaybeusedinconjunctionwithamodule
mountingsystemcompliantwithUL2703.Fortheseinstallations,the
SunPowermoduleandframestylemustbetestedandpartofthe
instructionsfortheListedmountingproduct.TheSunPowermodulemust
beinstalledinaccordancewiththeseinstructionsaswellasthemounting
system’sListedinstructions.
4.2ConnectiontoACCircuits
Itistheinstaller’sresponsibilitytoverifygridcompatibility(120/240or120/208
wye3phase4wire2pole).SunPowerACmodulesmustbeconnectedtoautility
sourceatthecorrectvoltageandfrequencyinordertooperateandproduce
power.TheyarenotstandalonegeneratorsanddonotcreateACvoltagethusare
notcapableofoperationindependentofautilitygeneratedACsignal.TheAC
modulesmustbeconnectedonlytoadedicatedbranchcircuit.TheACcablesand
connectorsarecertifiedandratedforthemaximumnumberofACunitsinparallel
only.Whenconnectingmodules,DONOTexceedthefollowingsinglebranch
circuitmaximumnumberofmodules:
240VAC:12(singlephase)
208VAC:10(twopolewye)
Thiscircuitmustbeprotectedbyovercurrentprotection.
CAUTION!Toreducetheriskoffire,connectonlytoa
circuitprovidedwith20Amaximumbranchcircuit
overcurrentprotectioninaccordancewiththeNational
ElectricalCode,ANSI/NFPA70.
Belowarethemajorinstallationsteps:
1. InstalltheFieldwireableconnectorpair,optionalJBox
2. PositiontheEnphaseQCable
Permodule:
3. PositionACmoduleandpopoutmicroinverters.RefertoSection
5.3forillustration
4. ConnectmicroinverterstoQCableconnector
5. InstallACModules
6. ManageQcabletomoduleframeandrail
Perrow:
7. Createinstallationmap
8. TerminateQcableatlastmicroinverter
9. ConnecttoJBox
10. Energizesystem
4.3CableManagement
UsecableclipsorcabletieswrapstoattachtheACcabletotheracking.Thecable
mustbesupportedtoavoidanycable
unduesagasperlocalrequirement.
ForPerformance3ACmodules,becareful
tonotunplugtheDCcablepremountedin
factoryintospecificcablesupports.
Dressanyexcesscablinginloopssothatit
doesnotcontacttheroof.Donotform
loopssmallerthan4.75inch(12cm)in
diameter.
4.4MicroinvertersConnection
RefertothemajorinstallationstepsdefinedinSection4.2andlistenforaclick:
1)whenthemicroinvertersarepopoutand
2)whenACconnectorsengage
InspecttheACconnectorstoensurethattheyare
notbroken,misshapen,orotherwisedegraded
priortoconnection.
CoveranyunusedconnectorsontheACcable
withEnphaseSealingCaps.Listenforaclickas
thesealingcapsengage.
CAUTION!InstallsealingcapsonallunusedACconnectors
astheseconnectorsbecomelivewhenthesystemis
energized.Sealingcapsarerequiredforprotectionagainst
moistureingress.
5.0 ModuleMounting
ThissectioncontainsinformationforSunPowerTypeEACmodules;TypeGAC
andSunPowerTypeHACmodules.Ensurethatyouusethecorrectinformation
foryourmoduletype.
TheSunPowerLimitedWarrantyforPVModulesiscontingentuponmodules
beingmountedinaccordancewiththerequirementsdescribedinthissection.
5.1SiteConsiderations
SunPowermodulesshouldonlybemountedinlocationsthatmeetthefollowing
requirements:
OperatingTemperature:AllSunPowerACmodulesmustbemountedin
environmentsthatensurethatthemoduleswilloperatewithinthefollowing
maximumandminimumtemperatures:
Max.OperatingCellTemp.+85°C(+185°F)
Max.AmbientTemp.+50°C(+122°F)
Min.OperatingTemp.−40°C(40°F)
DesignStrength:SunPowerTypeE,TypeGandTypeHACmodulesaredesigned
tomeetamaximumpositive(orupward,e.g.wind)andnegative(ordownward,
e.g.staticload)designpressurewhenmountedinthemountingconfigurations
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
specifiedinSection5.2.(Designstrengthof2400Pacorrespondsapproximatelyto
awindspeedof130km/h(81mph).SunPowerACmoduleshavealsobeen
evaluatedtoUL1703forapositiveornegativedesignloadof30psf.)
TypeE.ThefollowingimageandtableshowwheretomounttotheTypeE
moduleframe;anddefinesmountingrangesandtheresultingloadratings
achievedforeachrange:
MountingRange
Toleranceareidenticalat
eachmodulecorner
in./mmfromcorner
LoadRating
(Pa)*
Wind
(upanddown)
Snow
(down)
R1
02/050
DONOTMOUNT!
R2
211.8/5030030006000
R3
11.815.75/30040030006000
R4
214.75/5037530003000
R5DONOTMOUNT!
R6DONOTMOUNT!
*DesignloadvaluesmaybeusedasASDdesignloads.
TypeGandTypeH.
Important!ThefollowingimageandtablesshowwheretomounttotheTypeG
andHmoduleframeandtheallowableloadratingscorrespondingtothe
mountingzoneschosen.Tousethetables,identifythetwomountingzonesin
whichyouwishtomount.YoumaychoosetomountatanylocationinzonesA,B,
andC,aslongasthemountingpointsaresymmetricaboutoneaxisofthe
module.Identifythecombinationofmountingzonesyouhavechoseninthe
tableandthenrefertothecorrespondingloadrating.Notealsothatloadratings
aredifferentformodulessupportedbyrails;versussystemsthatattachmodules
withoutrails.
Table1.MountingConfigurationandLoadResistance
Mounting
Method
Mounting
(1)
Test/
Design
Load(2)
Downward(+)/
Upward()Pressure
(Pa)(1)
ASeries/MSeries
Rail
Supported
w/oRail
Support
TopClamp
BB
TestLoad8100/40505400/3600
DesignLoad5400/27003600/2400
CC
TestLoad2400/25502400/2400
DesignLoad1600/17001600/1600
AA
TestLoad3600/24002400/2400
DesignLoad2400/16001600/1600
EE
TestLoad
NA2400/2400
DesignLoad1600/1600
Boltor
Invisimount
Clamps
BB
TestLoad9000/54005400/5400
DesignLoad6000/36003600/3600
CC
TestLoad4200/42003600/4200
DesignLoad2800/28002400/2800
AA
TestLoad4500/30003000/3000
DesignLoad3000/20002000/2000
 DDDONOTMOUNT
(1) Ifmountinginmultiplezones,mustusethelowervalueofthetwozones.
(2) Testloadsareevaluatedat1.0factorofsafety,andDesignloadsare
calculatedusing1.5factorofsafety(Testload=1.5xDesignload).Design
loadvaluesmaybeusedasASDdesignloads.
Whenmountingmodulesinsnowproneorhighwindenvironments,specialcare
shouldbetakentomountthemodulesinamannerthatprovidessufficientdesign
strengthwhilemeetinglocalcoderequirements.
ExcludedOperatingEnvironmentsandReconfigurations
CertainoperatingenvironmentsarenotrecommendedforSunPowerACmodules,
andareexcludedfromtheSunPowerLimitedWarrantyforthesemodules.Contact
SunPowerifthereareanyunansweredquestionsconcerningtheoperating
environment.
5.2MountingConfigurations
Modulesmaybemountedattheappropriateorientationtomaximizesunlight
exposure.
Inordertopreventwaterfromenteringthejunctionbox(whichcouldpresenta
safetyhazard),modulesshouldbeorientedsuchthatthejunctionboxisinthe
uppermostpositionandshouldnotbemountedsuchthatthetopsurfacefaces
downward.Inaddition,ensurethemoduleorientationalsopreventsthe
microinverterfromdirectexposuretorain,UVandotherharmfulweatherevents
(ice/snow).
Clearancebetweenthemoduleframeandmountingstructureorgradeisrequired
topreventwiringdamageandtoenableairtocirculatebehindthemodule.A
minimumof2″ (5cm)isrequiredbetweenthemoduleframeandstructureor
ground.
SunPowerACmodulesareonlyNRTLListedforusewhentheirfactoryframesare
fullyintact.Donotremoveoralteranymoduleframe.Creatingadditional
mountingholesmaydamagethemoduleandreducethestrengthoftheframe.
Modulesmaybemountedusingthefollowingmethodsonly:
1) PressureClampsorClips:Mountthemodulewiththeclipsattachedtothe
longersidesofthemodule.RefertotheallowablerangesinSection5.0.
Installersmustensuretheclampsareofsufficientstrengthtoallowforthe
maximumdesignpressureofthemodule.
2) EndMount:Endmountingisthecapturemountingofthemodule’sshorter
sidestoasupportingrail.Theendmountingrailandclipsorclampsmustbe
ofsufficientstrengthtoallowforthemaximumdesignpressureofthe
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
module.Verifythiscapacitywiththemountingsystemvendorbefore
installation.
3) SunPower,SunPowerspecified,orSunPowersuppliedmountingsystems:
ModulesmountedwithstrictadherencetoSunPowerdocumentation,using
hardwaresystemssuppliedbyorspecifiedbySunPower.
5.3HandlingofModulesduringInstallation
Neverliftormovethemodulesusingcablesorthejunctionboxunderany
circumstances.Donotplacemodulesfaceforwardindirectcontactwithabrasive
surfacessuchasroofs,driveways,woodenpallets,railings,orwalls.Thefront
surfaceofamoduleissensitivetooilsandabrasivesurfaces,whichmayleadto
scratchesandirregularsoiling.
SunPowerrecommendshandlingmoduleswithglovesandnottouchingthefront
surface.Anyfingerprintsresultingfrominstallationcanbereducedbyfollowing
thewashingguidelinesinSection6.0.Agivenmodule’sproductdatasheetspecifies
theglasstypeituses.
BeforeinstallingtheACmodule,themicroinvertersmustbeliftedfromthe
shippingposition,facesyou.Usingbothhands,liftthemicroinverterup.Youwill
hearfourclicksasthemicroinverterlocksintotheinstallationposition.Ensurethe
fourlatchesarelocked,andthemicroinverterisnottilted.
ShippingPosition:
InstallPosition:
6.0 Maintenance
Visuallyinspectallmodulesannuallytoverifytheintegrityofboththeelectrical
andthemechanicalconnections;andtoverifytheabsenceofcorrosion.Thisvisual
inspectionshouldbeperformedbyanauthorizedSunPowerDealerortrained
SunPowersupportpersonnel.
Periodiccleaningofmodulesisrecommendedbutisnotrequired.Periodic
cleaninghasresultedinimprovedmoduleperformance,especiallyinregionswith
lowlevelsofannualprecipitation(fewerthan18.25inchesannually).Consultyour
Dealerorsupplieraboutrecommendedcleaningschedulesforyourarea.Toclean
amodule,sprayitwithpotable,nonheatedwater.Normalwaterpressureismore
thanadequate,butpressurizedwater(upto1500psi)maybeused.Fingerprints,
stains,oraccumulationsofdirtonthefrontsurfaceofthemodulemayberemoved
asfollows:rinsetheareaandwait5minutes.Rewettheareaandthenuseasoft
spongeorseamlessclothtowipetheglasssurfaceinacircularmotion.NEVERuse
harshcleaningmaterialssuchasscouringpowder,steelwool,scrapers,blades,or
othersharpinstrumentstocleanmoduleglass.Useofsuchmaterialsonthe
moduleswillvoidtheproductwarranty.
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
7.0 ElectricalCharacteristicsandGridInteraction
TypeE.
VoltageandFrequencyLimitsforUtilityInteraction
c
Condition
SimulatedSourceMaximumTime(sec)at60Hz
a
beforecessationofcurrentto
thesimulatedutility
Voltage(V)Frequency(Hz)
A<0.50V
norb
Rated0.16
B0.50V
norb
≤V<1.20
V
nor
Rated2
C1.10V
norb
≤V<1.20
V
nor
Rated 1
D1.20V
nor
≤VRated 0.16
ERatedf>rated+0.50.16
FRatedf<rated0.70.16
GVoltVarAccuracyx

aNonadjustablemaximumclearingtimes
bNominalvoltageequals240Vlinetoline
cTripLimitaccuracy:Voltage±1.0%basedon240Vnominal,frequency‐±0.1Hz
IrmsTotaldurationSynchronizationinrush
current
TripTimeAccuracy
5.8A100ms0.2A20ms
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
TypeG.
VoltageandFrequencyLimitsforUtilityInteraction
c
Condition
SimulatedSource
MaximumTime(sec)at60Hz
a
beforecessationofcurrentto
thesimulatedutility
Voltage(V)
Frequency
(Hz)
A
<0.50V
norb
Rated
0.16
B
0.50V
norb
≤V<1.20V
nor
Rated
2
C
1.10V
norb
≤V<1.20V
nor
Rated
1
D
1.20V
nor
≤V
Rated
0.16
E
Rated
f>rated+0.5
0.16
F
Rated
f<rated0.7
0.16
G
VoltVar
Accuracy
6%
aNonadjustablemaximumclearingtimes
bNominalvoltageequals240Vlinetoline
cTripLimitaccuracy:Voltage±1.0%basedon240Vnominal,frequency‐±0.1Hz
IrmsTotaldurationSynchronizationinrush
current
TripTimeAccuracy
5.8A100ms0.2A2linecycles
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
TypeH.

VoltageandFrequencyLimitsforUtilityInteraction
c
Condition
SimulatedSource
MaximumTime(sec)at60Hz
a
beforecessationofcurrentto
thesimulatedutility
Voltage(V)
Frequency
(Hz)
A
<0.50V
norb
Rated
0.16
B
0.50V
norb
≤V<1.20V
nor
Rated
2
C
1.10V
norb
≤V<1.20V
nor
Rated
1
D
1.20V
nor
≤V
Rated
0.16
E
Rated
f>rated+0.5
0.16
F
Rated
f<rated0.7
0.16
G
VoltVar
Accuracy
6%
aNonadjustablemaximumclearingtimes
bNominalvoltageequals240Vlinetoline
cTripLimitaccuracy:Voltage±1.0%basedon240Vnominal,frequency‐±0.1Hz
IrmsTotaldurationSynchronizationinrush
current
TripTimeAccuracy
5.8A100ms0.2A2linecycles
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
TypeE.
TypeG.

18351835 72.2
1017 40.0
30[1.2] 22[.87]
32[1.26] 24[.94]
Gen 5.1 Frame Profile
Gen 5.2 Frame Profile
40[1.57] 40[1.57]
40[1.57] 40[1.57]
367.7[14.32]
46.5[1.83]
SUNPOWERCORPORATION
531725RevJ
©2022SunPowerCorporation.Allrightsreserved.Specificationsincludedinthisdocumentaresubjecttochangewithoutnotice.
TypeH.
1872 73.7
1032 40.6
32[1.26] 24[.94]
Gen 5.2 Frame Profile
40[1.57] 40[1.57]
375.2[14.77]
46.5[1.83]
Ground Holes
24[.94]
40[1.57]
32[1.26]
40[1.57]
Gen 5.2 Frame Profile
382.70
[15.07]
249mm [9.79]
1100 mm [43.3]
1872 mm [73.7]
1032 mm [40.6]
Mounng Holes
4X Ø 6.8mm [0.27]
4X Ø 4.2mm [0.17]
Ground Holes
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

SunPower Type E Flexible 100 watt 12 Volt Solar Panel User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI