www.e-sensors.com.twwww.e-sensors.com.tw
BX 2-1
SureCross™
DX80 單點對多點模組
§ 工業無線I/O網路,能夠在嚴酷的環境下執行,
可節省昂貴的線材費用。
§ 基本的網路包括通道系統控制和一個或多個節點,
可達到遠端監視和遠端控制I/O。
§ 節點模組設置容易,便可與通道模組傳遞資料。
§ 利用跳頻技術(FHSS)分時多工(TDMI)可穩定使用於
工業環境來傳輸I/O資料。
§ Flex Power™模組支援+10~30Vdc,太陽能板、
電池模組。
§ 擁有堅固且達IP67防水等級的外殼。
通道模組
§通道模組為無線網路系統的母機
§具有Modbus通訊協定
§具有數位及類比等多種I/O點
節點模組
§節點模組為無線網路系統的子機
§具有多種電源選擇
§具有數位及類比等多種I/O點
www.e-sensors.com.twwww.e-sensors.com.tw
BX 2-2
SureCross™ DX80 單點對多點模組
DX80 EtherNet/IP and Modbus TCP 通道模組
DX80 Modbus RTU 通道模組 , 10–30V dc
頻率 型號
頻率
防護等級
型號
www.e-sensors.com.twwww.e-sensors.com.tw
BX 2-3
SureCross™ DX80 單點對多點模組
DX80 通道模組, FlexPower
DX80 節點模組, 10~30Vdc-Analog and Discrete
DX80 節點模組, FlexPower -Analog and Discrete
頻率
頻率
防護等級
防護
等級
型號
型號
Printed in USA 12/09 P/N 131933 rev. E
SureCross™ DX80 GatewayPro
GatewayPro models for protocol conversion or web-based configuration
WARNING . . . Not To Be Used for Personnel Protection
Never use these products for personnel protection. Doing so could lead to serious injury or death.
These products do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A failure or
malfunction can cause either an energized or de-energized output condition. Consult your current Banner Safety Products catalog for safety
products that meet OSHA, ANSI, and IEC standards for personnel protection.
Features
The SureCross™ DX80 is a radio frequency network system built around a Gateway and one
or more Nodes.
+10 to 30V dc power input•
Modbus serial interface and Ethernet interface•
Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple •
Access (TDMA) control architecture combine to ensure reliable data delivery within the
unlicensed Industrial, Scientific, and Medical (ISM) bands
Transceivers provide two-way communication between the Gateway and Node, including •
fully acknowledged data transmission
Site Survey analyzes the network’s signal strength and reliability•
External or internal antenna•
For additional information and a complete list of accessories, including FCC approved
antennas, refer to Banner Engineering’s website, www.bannerengineering.com/surecross.
Model Power Feature Frequency Antenna
DX80P9T6S
+10 to 30V dc
Modbus/TCP or EtherNet/IP
communication protocol
900 MHz ISM Band
External
DX80P9T6W Internal
DX80P2T6S
2.4 GHz ISM Band
External
DX80P2T6W Internal
DX80P9A6S
Modbus/TCP protocol,
Configuration capability using the
Web Configurator
900 MHz ISM Band
External
DX80P9A6W Internal
DX80P2A6S
2.4 GHz ISM Band
External
DX80P2A6W Internal
Models
900 MHz
2.4 GHz
Banner Engineering Corp.•Minneapolis,MNU.S.A
www.bannerengineering.com•Tel:763.544.3164
2 P/N 131933 rev. E
SureCross™ DX80 GatewayPro
Overview
TherearetwobasicmodelsoftheGatewayPro:DX80P*T6*andDX80P*A6*.
DX80P*T6*
TheT6modelactsasaprotocolconverteronly,offeringtheModbus/TCPorEtherNet/IPcommunicationprotocols.
DX80P*A6*
TheA6modelincludesDX80wirelessnetworkconguration,ModbusRTUmaster,Modbus/TCPclient/server,ScriptBasic,e-mail,data
logging, and trending.
Host Connected - DX80 GatewayPro
Connect a DX80 GatewayPro to a host system using the industrial Ethernet connection on the DX80 GatewayPro. To connect the DX80
GatewayPro directly to the host system without using an Ethernet switchbox/hub, use a crossover cable. When using an Ethernet hub, use a
straight Ethernet cable.
By default, the DX80 GatewayPro is a Modbus/TCP or EtherNet/IP™ server. To configure the GatewayPro as a Modbus client device, change
the configuration using the configuration Web pages.
P/N 131933 rev. E 3
Banner Engineering Corp.•Minneapolis,MNU.S.A
www.bannerengineering.com•Tel:763.544.3164
SureCross™ DX80 GatewayPro
Hookup Diagrams
For additional information, including installation and setup, weatherproofing, device menu
maps, troubleshooting, and a list of accessories, refer to the SureCross™ DX80 Wireless I/O
Network product manual, Banner p/n 132607.ForModbusRTU,Modbus/TCP,andEtherNet/
IP™ register maps, refer to Banner document p/n 132114.
Modbus Register Block
I/O
Point*
Gateway
Modbus
Holding
Register
Node
Modbus
Register
1 1 1+(Node#×16)
2 2 2+(Node#×16)
3 3 3+(Node#×16)
4 4 4+(Node#×16)
5 5 5+(Node#×16)
6 6 6+(Node#×16)
7 7 7+(Node#×16)
8 8 8+(Node#×16)
9 9 9+(Node#×16)
10 10 10+(Node#×16)
11 11 11+(Node#×16)
12 12 12+(Node#×16)
13 13 13+(Node#×16)
14 14 14+(Node#×16)
15 15 15+(Node#×16)
16 16 16+(Node#×16)
*ThesearetheI/Opointsasdisplayedonthedevice
LCD.
No. Color Description
1 Brown 10 to 30V dc Input
2 White RS485/D1/B/+
3 Blue dc common (GND)
4 Black RS485/D0/A/−
5 Gray Comms Gnd
5-pin M12 Euro Hookup
No. Color Description
1 White/Orange +Tx
2 White/Blue +Rx
3 Orange −Tx
4 Blue −Rx
Industrial Ethernet Hookup
Banner Engineering Corp.•Minneapolis,MNU.S.A
www.bannerengineering.com•Tel:763.544.3164
4 P/N 131933 rev. E
SureCross™ DX80 GatewayPro
Device Configuration
Switches
Device Settings 1 2 3 4
RotarySwitchAddressMode OFF*
Extended Address Mode ON
*Defaultconguration
Address Mode
The SureCross wireless devices may use one of two types of
addressingmodes:rotaryswitchaddressingorextendedaddressing.
In rotary switch address mode, the left rotary dial establishes the
network ID and the right rotary dial sets the device ID. The wireless
networkisrestrictedtoamaximumof16devices.
Extended address mode uses a security code to “bind” Nodes
to a specific Gateway. Bound Nodes can only send and receive
information from the Gateway they are bound to. In extended
addressmode,wirelessnetworksmaycontainupto56radiodevices.
For more information on extended address mode, refer to the
SureCross™ Wireless I/O Network product manual.
The device ships in rotary switch address mode by default, with the
DIP switch in the OFF position. To use extended address mode,
change the DIP switch to the ON position.
Turn the Power Off
Before making any changes to the DIP switch
positions, disconnect the power. For devices
with batteries integrated into the housing,
remove the battery.
Accessing the DIP Switches
ToaccesstheDIPswitches,followthesesteps:
Unscrew the four screws that mount the cover to the bottom 1.
housing.
Removethecoverfromthehousingwithoutdamagingthe2.
ribbon cable or the pins the cable plugs into.
Gently unplug the ribbon cable from the board mounted into 3.
the bottom housing.
Removetheblackcoverplatefromthebottomofthe4.
device’s cover.
The DIP switches are located behind the rotary dials. After making the
necessary changes to the DIP switches, place the black cover plate
back into position and gently push into place. Plug the ribbon cable
in after verifying that the blocked hole lines up with the missing pin.
Mount the cover back onto the housing.
P/N 131933 rev. E 5
Banner Engineering Corp.•Minneapolis,MNU.S.A
www.bannerengineering.com•Tel:763.544.3164
SureCross™ DX80 GatewayPro
Specifications
Many of the parameters are configurable. The values in the tables represent factory defaults unless otherwise noted.
General
Power*
+10 to 30V dc
ForEuropeanapplications:+10to24Vdc,±10%
Power Consumption
Lessthan1.4W(60mA)at24Vdc
Mounting
#10orM5(M5hardwareincluded)
M5FastenersMax.TighteningTorque
0.56N•m(5in•lbf)
Case Material
Polycarbonate
Weight
0.26kg(0.57lb.)
Indicators
Two LED, bi-color
Switches
Two Push Buttons
Display
Six Character LCD
* ForEuropeanapplications,powertheDX80fromaLimitedPowerSourceasdenedinEN60950-1.
It is Banner Engineering’s intent to fully comply with all national and regional regulations regarding radio frequency emissions. Customers who want to re-export this product to
a country other than that to which it was sold must ensure that the device is approved in the destination country. A list of approved countries appears in the SureCross DX80
Wireless Product Manual, in the Agency Certifications section. Consult with Banner Engineering if the destination country is not on this list.
Radio
Range*
900 MHz: Up to 4.8 kilometers (3 miles)
2.4 GHz: Up to 3.2 kilometers (2 miles)
Transmit Power
900 MHz: 21 dBm Conducted
2.4 GHz:18dBmConducted,≤20dBmEIRP
Spread Spectrum Technology
FHSS (Frequency Hopping Spread Spectrum)
Antenna Connector
Ext.ReversePolaritySMA,50Ohms
Antenna Max. Tightening Torque
0.45N•m(4in•lbf)
Link Timeout
Configurable, up to 2 minutes
*Withthestandard2dBantenna.High-gainantennasareavailable,buttherangedependsontheenvironmentandlineofsight.Todeterminetherangeofyourwireless
network, perform a Site Survey.
Communication
ModbusRTU
Interface
2-wireRS-485
BaudRates
9.6k,19.2k(default),or38.4k
Data Format
8 data bits, no parity, 1 stop bit
Modbus/TCP, EtherNet/IP™
Interface
4-wire Industrial Ethernet
DataRate
10/100 Mbps, full or half duplex, auto sensing
Banner Engineering Corp.•Minneapolis,MNU.S.A
www.bannerengineering.com•Tel:763.544.3164
6 P/N 131933 rev. E
SureCross™ DX80 GatewayPro
Certifications, Radio
900 MHz Models
FCCIDTGUDX80:ThisdevicecomplieswithFCCPart15,SubpartC,15.247
IC:7044A-DX8009
2.4 GHz Models
FCCIDUE300DX80-2400:ThisdevicecomplieswithFCCPart15,SubpartC,15.247
ETSI/EN:InaccordancewithEN300328:V1.7.1(2006-05)
IC:7044A-DX8024
Environmental
EnvironmentalRating*
IECIP67;NEMA6
OperatingTemperature**
−40to+85°C(Electronics);−20to+80°C(LCD)
Operating Humidity
95%max.relative(non-condensing)
RadiatedImmunity
10V/m,80-2700MHz(EN61000-6-2)
Shock and Vibration
IEC68-2-6andIEC68-2-7
Shock:30g,11millisecondhalfsinewave,18shocks
Vibration:0.5mmp-p,10to60Hz
* PleaserefertotheSureCross™DX80WirelessI/ONetworkproductmanual,Bannerp/n132607,forinstallationandwaterproonginstructions.
** Operatingthedevicesatthemaximumoperatingconditionsforextendedperiodscanshortenthelifeofthedevice.
Included with Device Model Qty Item
Mounting Hardware Kit BWA-HW-001
4 Screw,M5-0.8x25mm,SS
4 Screw,M5-0.8x16mm,SS
4 Hexnut,M5-0.8mm,SS
4 Bolt, #8-32 x 3/4”, SS
Ethernet Crossover Cable BWA-EX2M
1 EthernetCable,M12Industrial/RJ45,Crossover,2meter
Antenna* BWA-9O2-C or
BWA-2O2-C
1 Antenna,902-928MHz,2dBdOmni,RubberSwivelRP-SMAMale,or
Antenna,2.4GHz,2dBdOmni,RubberSwivelRP-SMAMale
SureCross Literature CD 79685
1 SureCross Literature CD
SureCross Quick Start Guide 128185
1 SureCross Quick Start Guide
Data sheet
1
* Internalantennadevicesdonotshipwiththisantenna
P/N 131933 rev. E 7
Banner Engineering Corp.•Minneapolis,MNU.S.A
www.bannerengineering.com•Tel:763.544.3164
SureCross™ DX80 GatewayPro
Accessories
Part No. Model No.
77669 BWA-E2M Ethernetcable,RSCDRJ45440,2M
78469 BWA-E8M Ethernetcable,RSCDRJ45440,8M
78467 BWA-EX2M Ethernetcable,crossover,RSCDRJ45CR440,2M
Use a crossover cable to connect the DX80 GatewayPro to a host system without using an Ethernet switchbox or hub. When using a switchbox
or hub, use the straight cables.
BannerEngineeringCorp.,9714TenthAve.No.,Minneapolis,MNUSA55441•Phone:763.544.3164•www.bannerengineering.com•Email:[email protected]
SureCross™ DX80 Gateway Pro
P/N 131933 rev. E
WARRANTY:BannerEngineeringCorp.warrantsitsproductstobefreefromdefectsforoneyear.Banner
Engineering Corp. will repair or replace, free of charge, any product of its manufacture found to be defective at
the time it is returned to the factory during the warranty period. This warranty does not cover damage or liability
for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or
implied.
CAUTION . . .
Make no modifications to this product.
Any modifications to this product not
expressly approved by Banner Engineering could
void the user’s authority to operate the product.
Contact the Factory for more information.
All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of products, prior to their order, without notice.
BannerEngineeringreservestherighttoupdateorchangedocumentationatanytime.Forthemostrecentversionofanydocumentation,pleaserefertoourwebsite:www.
bannerengineering.com.©2007BannerEngineeringCorp.Allrightsreserved.
Always use lightning arrestors/surge protection with all remote antenna systems to avoid invalidating the Banner
Engineering Corp. warranty. No surge protector can absorb all lightning strikes. Do not touch the SureCross
device or any equipment connected to the SureCross device during a thunderstorm.
The manufacturer does not take responsibility for the
violation of any warning listed in this document.
For more information:
Contact your local Banner
representative
or
Banner Corporate Offices
around the world.
Corporate Headquarters Europe Latin America
Banner Engineering Corp.
9714TenthAve.North
Mpls.,MN55441
Tel:763-544-3164
www.bannerengineering.com
Banner Engineering Europe
Park Lane
Culliganlaan 2F
Diegem B-1831 BELGIUM
Tel:32-24560780
Fax:32-24560789
www.bannereurope.com
Contact Banner Engineering Corp.
(US) or e-mail
Mexico:
Brazil:
Asia China Asia Japan Asia India
Banner Engineering China
ShanghaiRepOfce
Rm.G/H/I,28thFlr.
CrossRegionPlaza
No.899,LinglingRoad
Shanghai 200030 CHINA
Tel:86-21-54894500
Fax:86-21-54894511
www.bannerengineering.com.cn
Banner Engineering Japan
Cent-UrbanBuilding305
3-23-15Nishi-Nakajima
Yodogawa-Ku,Osaka532-0011
JAPAN
Tel:81-6-6309-0411
Fax:81-6-6309-0416
www.bannerengineering.co.jp
Banner Engineering Asia
Taiwan
Neihu Technology Park
5F-1,No.51,Lane35,JihuRd.
Taipei 114 TAIWAN
Tel:886-2-8751-9966
Fax:886-2-8751-2966
www.bannerengineering.com.tw
Banner Engineering India
Pune Head Quarters
Office No. 1001
Sai Capital, Opp. ICC
SenapatiBapatRoad
Pune411016INDIA
Tel:91-20-66405624
Fax:91-20-66405623
www.bannerengineering.co.in
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11

Ask a question and I''ll find the answer in the document