3com Switch 4070 Getting Started Manual

Category
Network switches
Type
Getting Started Manual

This manual is also suitable for

http://www.3com.com/
Part No. DUA1770-9AAA04
Published April 2003
3Com
®
Switch 40x0 Family
Getting Started Guide
3C17707, 3C17708, 3C17709
DUA1770-9AAA04.book Page 1 Monday, April 14, 2003 11:33 AM
3Com Corporation
5500 Great America
Parkway, Santa Clara,
California 95052-8145
Copyright © 2003, 3Com Corporation. All rights reserved. No part of this documentation may be reproduced
in any form or by any means or used to make any derivative work (such as translation, transformation, or
adaptation) without written permission from 3Com Corporation.
3Com Corporation reserves the right to revise this documentation and to make changes in content from time
to time without obligation on the part of 3Com Corporation to provide notification of such revision or change.
3Com Corporation provides this documentation without warranty, term, or condition of any kind, either
implied or expressed, including, but not limited to, the implied warranties, terms or conditions of
merchantability, satisfactory quality, and fitness for a particular purpose. 3Com may make improvements or
changes in the product(s) and/or the program(s) described in this documentation at any time.
If there is any software on removable media described in this documentation, it is furnished under a license
agreement included with the product as a separate document, in the hard copy documentation, or on the
removable media in a directory file named LICENSE.TXT or !LICENSE.TXT. If you are unable to locate a copy,
please contact 3Com and a copy will be provided to you.
UNITED STATES GOVERNMENT LEGEND
If you are a United States government agency, then this documentation and the software described herein are
provided to you subject to the following:
All technical data and computer software are commercial in nature and developed solely at private expense.
Software is delivered as “Commercial Computer Software” as defined in DFARS 252.227-7014 (June 1995) or
as a “commercial item” as defined in FAR 2.101(a) and as such is provided with only such rights as are
provided in 3Com’s standard commercial license for the Software. Technical data is provided with limited rights
only as provided in DFAR 252.227-7015 (Nov 1995) or FAR 52.227-14 (June 1987), whichever is applicable.
You agree not to remove or deface any portion of any legend provided on any licensed program or
documentation contained in, or delivered to you in conjunction with, this User Guide.
Unless otherwise indicated, 3Com registered trademarks are registered in the United States and may or may not
be registered in other countries.
3Com, the 3Com logo, and SuperStack are registered trademarks of 3Com Corporation. XRN is a trademark of
3Com Corporation.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Inc.
Intel and Pentium are registered trademarks of Intel Corporation. Microsoft, MS-DOS, Windows, and Windows
NT are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of
Novell, Inc. UNIX is a registered trademark in the United States and other countries, licensed exclusively
through X/Open Company, Ltd.
Netscape Navigator is a registered trademark of Netscape Communications.
JavaScript is a trademark of Sun Microsystems.
All other company and product names may be trademarks of the respective companies with which they are
associated.
ENVIRONMENTAL STATEMENT
It is the policy of 3Com Corporation to be environmentally-friendly in all operations. To uphold our policy, we
are committed to:
Establishing environmental performance standards that comply with national legislation and regulations.
Conserving energy, materials and natural resources in all operations.
Reducing the waste generated by all operations. Ensuring that all waste conforms to recognized environmental
standards. Maximizing the recyclable and reusable content of all products.
Ensuring that all products can be recycled, reused and disposed of safely.
Ensuring that all products are labelled according to recognized environmental standards.
Improving our environmental record on a continual basis.
End of Life Statement
3Com processes allow for the recovery, reclamation and safe disposal of all end-of-life electronic components.
Regulated Materials Statement
3Com products do not contain any hazardous or ozone-depleting material.
Environmental Statement about the Documentation
The documentation for this product is printed on paper that comes from sustainable, managed forests; it is
fully biodegradable and recyclable, and is completely chlorine-free. The varnish is environmentally-friendly, and
the inks are vegetable-based with a low heavy-metal content.
DUA1770-9AAA04.book Page 2 Monday, April 14, 2003 11:33 AM
CONTENTS
ABOUT THIS GUIDE
Conventions 8
Related Documentation 9
Accessing Online Documentation 9
Product Registration 10
Documentation Comments 10
1 INTRODUCING THE 3COM SWITCH 40X0 FAMILY
About the 3Com Switch 40x0 Family 12
Summary of Hardware Features 13
3Com Switch 40x0 Family — Front View Detail 14
1000BASE-SX Ports 15
GBIC Ports 15
SFP Ports 16
10BASE-T/100BASE-TX/1000BASE-T Ports 16
Console Port 16
LEDs 17
3Com Switch 40x0 Family — Rear View Detail 19
Expansion Module Slot 19
Replaceable Power Supplies (PSUs) 20
Power Socket 20
Replaceable Fan Trays 20
Default Settings 21
2 INSTALLING THE SWITCH
Package Contents 24
Choosing a Suitable Site 24
Rack-mounting 25
Placing Units On Top of Each Other 26
Creating an XRN Distributed Fabric 26
How To Interconnect Units 27
DUA1770-9AAA04.book Page 3 Monday, April 14, 2003 11:33 AM
Rules For Interconnecting Units 27
The Power-up Sequence 28
Powering-up the 3Com Switch 40x0 28
Checking for Correct Operation of LEDs 28
Choosing the Correct 10/100/1000 Cables 29
Choosing the correct Fiber cables 30
GBIC Operation 30
Approved GBIC Transceivers 30
Inserting a GBIC Transceiver 31
Removing a GBIC Transceiver 32
SFP Operation 32
Approved SFP Transceivers 32
Inserting an SFP Transceiver 33
Removing an SFP Transceiver 34
3 SETTING UP FOR MANAGEMENT
Setting Up Overview 36
IP Configuration 37
Preparing for Management 38
Manually Configuring IP Information 39
Connecting to a Front Panel Port 39
Connecting to the Console Port 42
Viewing Automatically Configured IP Information 45
Using 3Com Network Supervisor 45
Connecting to the Console Port 46
Methods of Managing a Switch 48
Command Line Interface Management 48
Web Interface Management 49
SNMP Management 49
Setting Up Command Line Interface Management 50
CLI Management via the Console Port 50
CLI Management over the Network 50
Setting Up Web Interface Management 51
Pre-requisites 51
Web Management Over the Network 52
Setting Up SNMP Management 53
Pre-requisites 53
DUA1770-9AAA04.book Page 4 Monday, April 14, 2003 11:33 AM
Default Users and Passwords 53
Changing Default Passwords 54
4 PROBLEM SOLVING
Solving Problems Indicated by LEDs 56
Solving Hardware Problems 58
Solving Communication Problems 62
Solving Software Upgrade Problems 63
A SAFETY INFORMATION
Power Cord Set — Japan 65
Important Safety Information 66
L’information de Sécurité Importante 69
Wichtige Sicherheitsinformationen 72
B PIN-OUTS
Null Modem Cable 75
PC-AT Serial Cable 75
Modem Cable 76
RJ-45 Pin Assignments 76
C TECHNICAL SPECIFICATIONS
Switch 40x0 Family 79
D TECHNICAL SUPPORT
Online Technical Services 81
World Wide Web Site 81
3Com Knowledgebase Web Services 82
3Com FTP Site 82
Support from Your Network Supplier 82
Support from 3Com 83
Internet Support 83
Telephone Support 83
Returning Products for Repair 85
Contacting 3Com Support 86
DUA1770-9AAA04.book Page 5 Monday, April 14, 2003 11:33 AM
INDEX
REGULATORY NOTICES
DUA1770-9AAA04.book Page 6 Monday, April 14, 2003 11:33 AM
ABOUT THIS GUIDE
This guide provides all the information you need to install and use a
3Com
®
Switch 40x0 Family unit in its default state.
The guide is intended for use by network administrators who are
responsible for installing and setting up network equipment;
consequently, it assumes a basic working knowledge of LANs (Local Area
Networks).
Please refer to the CD-ROM that accompanies your Switch for the
following:
Management Interface Reference Guide — an online guide which
gives you detailed information on how to use the web interface and
command line interface to manage the Switch.
Other documentation relating to the 3Com Switch 40x0 Family.
3Com Network Supervisor — a powerful network management tool
for small to medium enterprise networks.
A number of other useful applications.
If the information in the release notes that are shipped with your product
differ from the information in this guide, follow the instructions in the
release notes.
Most user guides and release notes are available in Adobe Acrobat
Reader Portable Document Format (PDF) or HTML on the 3Com
World Wide Web site:
http://www.3com.com/
DUA1770-9AAA04.book Page 7 Monday, April 14, 2003 11:33 AM
8 ABOUT THIS GUIDE
Conventions Table 1 and Table 2 list conventions that are used throughout this guide.
Table 1 Notice Icons
Icon Notice Type Description
Information note Information that describes important features or
instructions.
Caution Information that alerts you to potential loss of data or
potential damage to an application, system, or device.
Warning Information that alerts you to potential personal
injury.
Table 2 Text Conventions
Convention Description
Screen displays This typeface represents information as it appears on the
screen.
Syntax The word “syntax” means that you must evaluate the syntax
provided and then supply the appropriate values for the
placeholders that appear in angle brackets. Example:
To change your password, use the following syntax:
system password <password>
In this example, you must supply a password for <password>.
Commands The word “command” means that you must enter the
command exactly as shown and then press Return or Enter.
Commands appear in bold. Example:
To display port information, enter the following command:
bridge port detail
The words “enter”
and “type”
When you see the word “enterin this guide, you must type
something, and then press Return or Enter. Do not press
Return or Enter when an instruction simply says “type.”
Keyboard key names If you must press two or more keys simultaneously, the key
names are linked with a plus sign (+). Example:
Press Ctrl+Alt+Del
Words in italics Italics are used to:
Emphasize a point.
Denote a new term at the place where it is defined in the
text.
Identify menu names, menu commands, and software
button names. Examples:
From the Help menu, select Contents.
Click OK.
DUA1770-9AAA04.book Page 8 Monday, April 14, 2003 11:33 AM
Related Documentation 9
Related
Documentation
In addition to this guide, each Switch documentation set includes the
following:
Management Quick Reference Guide
This guide contains:
a list of software features supported by each Switch.
a summary of the web interface and command line interface
commands for the Switch.
Release Notes
These notes provide information about the current software release,
including new features, modifications, and known problems.
Switch Implementation Guide
This guide contains information on the features supported by your
Switch and how they can be used to optimize your network. It is
supplied in PDF format on the CD-ROM that accompanies the Switch.
Management Interface Reference Guide
This guide provides detailed information about the web interface and
command line interface that enable you to manage the Switch. It is
supplied in HTML format on the CD-ROM that accompanies the
Switch.
There are other publications you may find useful:
Documentation accompanying the Expansion Modules.
Documentation accompanying the GBIC and SFP Transceivers.
Documentation accompanying 3Com Network Supervisor. This is
supplied on the CD-ROM that accompanies the Switch.
Accessing Online
Documentation
The CD-ROM supplied with your Switch contains the following online
documentation:
Switch Implementation Guide (PDF format).
Switch Management Interface Reference Guide (HTML format).
Other documentation relating to the Switch 40x0 Family (PDF format).
DUA1770-9AAA04.book Page 9 Monday, April 14, 2003 11:33 AM
10 ABOUT THIS GUIDE
To access the online documentation from the CD-ROM:
1 Insert the CD-ROM into the relevant CD-ROM drive. If your PC has
auto-run enabled, a splash screen will be displayed automatically.
2 Select the Documentation section from the contents page.
If the online documentation is to be accessed from a local drive or server,
you will need to access the CD-ROM contents via the root directory and
copy the files from the CD-ROM to a suitable directory.
The HTML Reference Guide is stored in the Docs/referenceguide
on the CD-ROM. The documentation is accessed using the index.htm
file.
The PDF Implementation Guide is stored in the
Docs/implementation directory of the CD-ROM.
3Com recommends that you copy the Docs/referenceguide
directory as a whole to maintain the structure of the files.
Product
Registration
You can register your Switch on the 3Com Web site to receive up-to-date
information on your product:
http://www.3com.com/register
You will need your product part number (3Cxxxxx), product serial number
and date of purchase to register your 3Com product.
Documentation
Comments
Your suggestions are very important to us. They will help make our
documentation more useful to you. Please e-mail comments about this
document to 3Com at:
Please include the following information when commenting, Document
title, Document part number (on the title page) and Page number (if
appropriate).
Example:
Part Number DUA1770-9AAA0x
3Com Switch 40x0 Family Getting Started Guide
Page 21
DUA1770-9AAA04.book Page 10 Monday, April 14, 2003 11:33 AM
1
INTRODUCING THE
3C
OM SWITCH 40X0 FAMILY
This chapter contains introductory information about the 3Com
®
Switch
40x0 Family and how it can be used in your network. It covers summary
information about the hardware and the following topics:
About the 3Com Switch 40x0 Family
3Com Switch 40x0 Family — Front View Detail
3Com Switch 40x0 Family — Rear View Detail
Default Settings
DUA1770-9AAA04.book Page 11 Monday, April 14, 2003 11:33 AM
12 CHAPTER 1: INTRODUCING THE 3COM SWITCH 40X0 FAMILY
About the 3Com
Switch 40x0 Family
The 3Com Switch 4050 is a mixed media device which consists of:
12 10BASE-T/100BASE-TX/1000BASE-T ports
6 1000BASE-SX ports
6 Gigabit Interface Convertor (GBIC) ports
The 3Com Switch 4060 is a mixed media device which consists of:
12 1000BASE-SX ports
6 10BASE-T/100BASE-TX/1000BASE-T ports
6 Gigabit Interface Convertor (GBIC) ports
The 3Com Switch 4070 device consists of:
24 Small Form Factor Pluggable (SFP) ports
You can also interconnect any combination of two Switches from the
3Com Switch 40x0 Family or the SuperStack
®
3 Switch 4900 Series to
create an XRN Distributed Fabric. This allows you to create a highly
resilient core around which you can build your network. For more
information about interconnecting Switches, see “Creating an XRN
Distributed Fabric” on page 26. For more information about 3Com XRN
Technology and how to use it in your network, refer to the
Implementation Guide on the CD-ROM that accompanies the Switch.
For information about using the software features of the Switch, refer to
the “Switch Management Interface Reference Guide” on the CD-ROM
that accompanies the Switch.
DUA1770-9AAA04.book Page 12 Monday, April 14, 2003 11:33 AM
About the 3Com Switch 40x0 Family 13
Summary of
Hardware Features
Table 3 summarizes the hardware features that are supported by the
Switch 40x0.
Table 3 Hardware features
Feature 3Com Switch 40x0 Family
Addresses Up to 12,000 supported
Up to 64 permanent entries
Forwarding Modes Store and Forward
Duplex Modes Half duplex only supported on
10BASE-T/100BASE-TX/1000BASE-T Mbps ports in
10/100 Mbps mode
All 1000 Mbps ports are full duplex only
Flow Control Supported on all ports
Smart auto-sensing Supported on all 10BASE-T/100BASE-TX/1000BASE-T
ports.
Not supported on 1000BASE-SX, GBIC and SFP ports.
Traffic Prioritization Supported (IEEE Std 802.1D, 1998 Edition)
Four traffic queues per port
Fast Ethernet and
Gigabit Ethernet Ports
Auto-negotiating 10BASE-T/100BASE-TX/1000BASE-T,
1000BASE-SX, GBIC and SFP ports
Mounting 19-inch rack or stand-alone mounting
Layer 3 Switching Support for wire-speed IP routing
Replaceable PSUs Replaceable PSU and slot for optional second replaceable
PSU
Hot Swap Fans Two identical hot swap fan trays are fitted
XRN Support eXpandable Resilient Networking (XRN) support. Allows
interconnection of two units to create a Distributed
Fabric.
DUA1770-9AAA04.book Page 13 Monday, April 14, 2003 11:33 AM
14 CHAPTER 1: INTRODUCING THE 3COM SWITCH 40X0 FAMILY
3Com Switch 40x0
Family — Front
View Detail
Figure 1 3Com Switch 4050 — front view
Figure 2 3Com Switch 4060 — front view
WARNING: RJ-45 Ports. These are shielded RJ-45 data sockets. They
cannot be used as standard traditional telephone sockets, or to connect
the unit to a traditional PBX or public telephone network. Only connect
RJ-45 data connectors, network telephony systems, or network
telephones to these sockets.
Either shielded or unshielded data cables with shielded or unshielded
jacks can be connected to these data sockets.
P
S
GBIC 1
P
S
GBIC 2
P
S
GBIC 4
P
S
GBIC 3
P
S
GBIC 6
P
S
GBIC 5
1000SX
P
S
19
20
21 22 23 24
19
20
21
22
23
24
10/100/1000
P
S
13
14
15 16 17 18
13
14
15
16
17
18
3Com Switch 4050
3C17708
UNIT STATUS
LAYER 3
2
PSU
1
FANS
R
F
1
2
UNIT
3
4
S
P
MODULE
TEMP
Unit Status LED
and Layer 3 LED
PSU LEDs
Fan LEDs
Unit LEDs
Module
Status LEDs
Temperature
LED
Yellow = 10/100Mbps Green = 1000Mbps On = enabled, link OK Flashing = disabled
P = Packet
S = Status
GBIC Ports
1000BASE-SX LEDs
Console Port
Front Fan Tray (behind door)
1000BASE-SX Ports
10BASE-T/100BASE-TX/1000BASE-T Ports
GBIC LEDs
10BASE-T/100BASE-TX/1000BASE-T LEDs
10/100/1000
P
S
13
14
15 16 17 18
13
14
15
16
17
18
10BASE-T/100BASE-TX/1000BASE-T Ports
P
S
GBIC 1
P
S
GBIC 2
P
S
GBIC 4
P
S
GBIC 3
P
S
GBIC 6
P
S
GBIC 5
1000SX
P
S
7
7
8
8
9
9
10
10
11
11
12
12
1000SX
P
S
19
20
21 22 23 24
19
20
21
22
23
24
10/100/1000
P
S
13
14
15 16 17 18
13
14
15
16
17
18
3Com Switch 4060
3C17709
UNIT STATUS
LAYER 3
2
PSU
1
FANS
R
F
1
2
UNIT
3
4
S
P
MODULE
TEMP
Unit Status LED
and Layer 3 LED
PSU LEDs
Fan LEDs
Unit LEDs
Module
Status LEDs
Temperature
LED
Yellow = 10/100Mbps Green = 1000Mbps On = enabled, link OK Flashing = disabled
P = Packet
S = Status
GBIC Ports
1000BASE-SX LEDs
Console Port
Front Fan Tray (behind door)
1000BASE-SX Ports
10BASE-T/100BASE-TX/1000BASE-T Ports
1000BASE-SX Ports
GBIC LEDs
10BASE-T/100BASE-TX/1000BASE-T LEDs
DUA1770-9AAA04.book Page 14 Monday, April 14, 2003 11:33 AM
3Com Switch 40x0 Family — Front View Detail 15
Figure 3 3Com Switch 4070 — front view
A fiber port can only be connected to an identical type of port. For
example, a 1000BASE-SX port connected to another 1000BASE-SX port
will work, whereas a 1000BASE-SX port connected to a 1000BASE-LX
port will not work.
1000BASE-SX Ports The auto-negotiating 1000BASE-SX ports have MT-RJ connectors.
The default state for these ports is auto-negotiation enabled, where the
speed, duplex and flow control modes are negotiated. As the speed and
duplex modes are fixed by the media type, only the flow control is
negotiated with the link partner. Alternatively, auto-negotiation can be
disabled and the flow control setting can be manually configured.
GBIC Ports The 6 GBIC ports support fiber Gigabit Ethernet short-wave (SX),
long-wave (LX) and long-haul (LH70) GBIC transceivers in any
combination. This offers you the flexibility of using GBIC transceivers to
provide connectivity between the Switch and remote 1000 Mbps
workgroups or to create a high capacity aggregated link backbone
connection.
The default state for these ports is auto-negotiation enabled, where the
speed, duplex and flow control modes are negotiated. As the speed and
duplex modes are fixed by the media type, only the flow control is
negotiated with the link partner. Alternatively, auto-negotiation can be
disabled and the flow control setting can be manually configured.
13
1
3Com Switch 4070
Unit Status
Layer 3
2
PSU Status
1
Fan Fault
R
F
1
2
Unit
3
4
S
P
Module
Temperature
Unit Status LED
and Layer 3 LED
PSU LEDs
Fan LEDs
Unit LEDs
Module
Status LEDs
Temperature
LED
On = enabled, link OK Flashing = disabled
P = Packet
S = Status
Console Port
Front Fan Tray (behind door)
SFP Ports
123
4
567 8
9
10 11
12
13 14 15
16
17 18 19 20
21
22 23
24
P
S
P
S
14
2
P
S
P
S
15
3
P
S
P
S
16
4
P
S
P
S
17
5
P
S
P
S
18
6
P
S
P
S
19
7
P
S
P
S
20
8
P
S
P
S
21
9
P
S
P
S
22
10
P
S
P
S
23
11
P
S
P
S
24
12
P
S
P
S
Console
(max) 19200,8,1,N
3C 17707
DUA1770-9AAA04.book Page 15 Monday, April 14, 2003 11:33 AM
16 CHAPTER 1: INTRODUCING THE 3COM SWITCH 40X0 FAMILY
SFP Ports The 24 SFP (Small Form Factor Pluggable) ports support fiber Gigabit
Ethernet short-wave (SX) and long-wave (LX) SFP Transceivers in any
combination. This offers you the flexibility of using SFP transceivers to
provide connectivity between the Switch and remote 1000 Mbps
workgroups or to create a high capacity aggregated link backbone
connection.
The default state for these ports is auto-negotiation enabled, where the
speed, duplex and flow control modes are negotiated. As the speed and
duplex modes are fixed by the media type, only the flow control is
negotiated with the link partner. Alternatively, auto-negotiation can be
disabled and the flow control setting can be manually configured.
10BASE-T/
100BASE-TX/
1000BASE-T Ports
The 10BASE-T/100BASE-TX/1000BASE-T ports have RJ-45 connectors and
are configured as Auto MDIX (cross-over).
The default state for these ports is auto-negotiation enabled, where the
speed, duplex and flow control modes of a link are automatically
detected to provide the highest available bandwidth with the link partner.
Alternatively, auto-negotiation can be disabled. These ports can be
manually configured to 10 Mbps half duplex, 100 Mbps half duplex,
10 Mbps full duplex or 100 Mbps full duplex. It is not possible to
manually configure a 1000 Mbps link as auto-negotiation is mandatory in
the 1000 Mbps standard. If auto-negotiation is disabled, Auto MDIX
cannot function and the ports are fixed as MDIX (cross-over) mode.
If auto-negotiation is disabled on a 1000 Mbps port, the speed will drop
to the highest available speed. By default this is 100 Mbps.
Console Port The console port allows you to connect a terminal and perform remote or
local out-of-band management. The console port uses a standard null
modem cable and is set to autobaud (up to a maximum of 19,200 baud),
8 data bits, no parity and 1 stop bit.
DUA1770-9AAA04.book Page 16 Monday, April 14, 2003 11:33 AM
3Com Switch 40x0 Family — Front View Detail 17
LEDs Table 4 lists LEDs visible on the front of the Switch, and how to read their
status according to color. For information on using the LEDs for problem
solving, see “Checking for Correct Operation of LEDs”
on page 28.
Table 4 LED behavior
LED Color Indicates
Port Status LEDs
Packet Yellow Packets are being transmitted/received on the port.
Off No packets are being transmitted/received on the port.
Status Green A high speed (1000 Mbps) link is present, and the port
is enabled.
Green flashing A high speed (1000 Mbps) link is present, but the port
is disabled.
Yellow A low speed (10/100 Mbps) link is present, and the
port is enabled (4050/4060 only).
Yellow flashing A low speed (10/100 Mbps) link is present, but the port
is disabled (4050/4060 only).
Yellow flashing
(fast)
Port has failed self-test and has automatically been
disabled.
Off No link is present.
Module Status LEDs
Green The Module is installed and supported. The Link Status
has been determined for a single port Module.
Yellow The Module is installed and supported. The Module
has multi-ports or there is no link for a single port
Module.
Yellow flashing The Module is installed but not supported. Note that
the unit will continue to operate normally.
Yellow flashing
(fast)
A port on the Module has failed POST and has been
automatically disabled.
Off The Module is not installed.
Unit LEDs
1–4 Green Determines the identity of the Switch when
interconnected to another Switch to create a
Distributed Fabric.
Off A fault has occurred.
Unit Status LED
Green The Switch is powered-up and operating normally.
DUA1770-9AAA04.book Page 17 Monday, April 14, 2003 11:33 AM
18 CHAPTER 1: INTRODUCING THE 3COM SWITCH 40X0 FAMILY
Unit Status LED (cont.)
Green flashing The Switch is either downloading software or is
initializing (which includes running a Power On Self
Test).
Yellow The Switch has failed its Power On Self Test
or
A port has failed and has been automatically disabled.
You can verify this by checking that the Port Status LED
is quickly flashing Yellow. If a port fails the Switch
passes its Power On Self Test and continues to operate
normally.
Off The Switch is not receiving power or there is a fault
with the Power Supply unit.
Layer 3 LED
Green The Switch software supports Layer 3.
Off The Switch software does not support Layer 3.
PSU LEDs (Front of Switch)*
Green PSU fitted and enabled
Red PSU fitted and not operational
Red flashing PSU has shut down due to over-heating
Off No PSU fitted
PSU LED (PSU Module)
Green The PSU module is installed and is supplying DC power
to the Switch.
Off The PSU module is not supplying power and may have
shut down due to a fault.
Fans (F = Front)
Red One or both fans have failed
Red flashing Fan Tray has been removed
Off Fan Tray fitted and enabled.
Fans (R = Rear)
Red One or both fans have failed
Red flashing Fan Tray has been removed
Off Fan Tray fitted and enabled.
LED Color Indicates
DUA1770-9AAA04.book Page 18 Monday, April 14, 2003 11:33 AM
3Com Switch 40x0 Family — Rear View Detail 19
* The PSU LEDs are visible on the front of the Switch and are marked ‘1’ for PSU 1 (bottom) and
‘2’ for PSU 2 (top).
3Com Switch 40x0
Family
Rear View
Detail
Figure 4 3Com Switch 40x0 Family — rear view
Expansion Module
Slot
You can use this slot to install an Expansion Module. Contact your
supplier for further information.
Temperature
Red flashing The Switch and/or the PSUs are above critical
temperature and may shut down.
Off The Switch and the PSUs are below critical
temperature.
Expansion Module Status LEDs
Green The module is installed and supported and a link is
present.
Yellow The module is installed and supported but there is no
link present or the link status cannot be determined.
Yellow flashing The Module is installed but not supported or has failed
self-test. Note that the unit will continue to operate
normally.
Off The Module is not installed.
Expansion Module Packet LEDs
Yellow Packets are being transmitted/received on the port.
Off No packets are being transmitted/received on the port.
LED Color Indicates
DUA1770-9AAA04.book Page 19 Monday, April 14, 2003 11:33 AM
20 CHAPTER 1: INTRODUCING THE 3COM SWITCH 40X0 FAMILY
WARNING: When an Expansion Module is not installed, ensure the
blanking plate is fitted by tightening all screws with a suitable tool.
Replaceable Power
Supplies (PSUs)
The Switch 40x0 has a bay for two internal power supplies. Contact your
supplier for further information. For information on installation and
removal, please refer to the documentation that accompanies the
replacement PSU.
The Switch 40x0 supports the 3Com AC power supply unit (3C17718).
WARNING: The system must not be left without a power supply or a
blanking plate in either of the two slots (except during replacement of
the power supplies). Tighten all screws with a suitable screwdriver.
WARNING: Care must be taken when removing a PSU as it may be hot.
The replacement of power supplies should be completed within two
minutes to avoid normal cooling being disturbed.
Power Socket Each Power Supply automatically adjusts its power setting to any power
voltage in the range 90-240 VAC.
WARNING: Mains power must be removed from the PSU before
removing the PSU. A PSU must only be powered once it has been
installed.
Replaceable Fan Trays The Switch 40x0 is provided with two identical fan trays which can be
replaced. Contact your supplier for further information. For information
on installation, please refer to the documentation that accompanies your
fan tray.
The Switch 40x0 supports the 3Com Fan Tray (3C17717).
WARNING: A fan tray can be temporarily removed and replaced while
the system is running without impacting operations. The system must not
be left with either fan tray removed for more than two minutes or
damage to the product may be caused. Tighten all screws with a suitable
screwdriver.
WARNING: Care must be taken when removing the fan tray as the fan
blades may continue to spin for a short time after removal. Keep fingers
clear.
DUA1770-9AAA04.book Page 20 Monday, April 14, 2003 11:33 AM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90

3com Switch 4070 Getting Started Manual

Category
Network switches
Type
Getting Started Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI