ESAB LKB 400W, LKB 400WS User manual

Category
Welding System
Type
User manual

This manual is also suitable for

ESAB LKB 400W, LKB 400WS is a step-switched welding power source for solid or cored wires with or without shielding gas. It allows welding with steel, stainless steel, and aluminum. The LKB 400W has a built-in cooling system for the welding torch, while the LKB 400WS does not. Both models feature adjustable burnback time, various welding voltage outputs, and overheating protection. An optional digital meter displays welding current and voltage.

ESAB LKB 400W, LKB 400WS is a step-switched welding power source for solid or cored wires with or without shielding gas. It allows welding with steel, stainless steel, and aluminum. The LKB 400W has a built-in cooling system for the welding torch, while the LKB 400WS does not. Both models feature adjustable burnback time, various welding voltage outputs, and overheating protection. An optional digital meter displays welding current and voltage.

Valid for serial no. 211--xxx--xxxx0349 301 038 020314
LKB 400W
LKB 400WS
112101103105107109111102021110025108024042106023061104022041100020040060001
Bruksanvisning
Brugsanvisning
Bruksanvisning
Käyttöohjeet
Instruction manual
Betriebsanweisung
Manuel d’instructions
Gebruiksaanwijzing
Instrucciones de uso
Istruzioni per l’uso
Manual de instruções
Ïäçãßåò ÷ñÞóåùò
Instrukcja obs³ugi
43
1. DECLARATION OF CONFORMITY ...................................................................................................44
2. SAFETY .............................................................................................................................................. 44
3. INTRODUCTION ................................................................................................................................. 45
3.1 TECHNICAL DATA ........................................................................................................................ 45
4.
INSTALLATION .................................................................................................................................. 46
4.1 MAINS SUPPLY ............................................................................................................................. 46
4.2 UNPACKING ................................................................................................................................... 46
4.3 FILLING TANK WITH COOLING LIQUID ...................................................................................... 46
4.4 CONNECTING GAS HEATER ....................................................................................................... 46
5. OPERATION ....................................................................................................................................... 47
5.1 CONTROLS AND INDICATORS LKB 400W ................................................................................. 47
5.2 CONTROLS AND INDICATORS LKB 400WS ............................................................................... 49
6. MAINTENANCE .................................................................................................................................. 51
6.1 CLEANING ...................................................................................................................................... 51
7. SPARE PARTS ORDERING ............................................................................................................... 51
8. ACCESSORIES .................................................................................................................................. 51
8.1 METER ASSEMBLY INSTRUCTION ............................................................................................. 51
9. SCHEMATIC DIAGRAM ..................................................................................................................... 133
10. SPARE PARTS LIST ........................................................................................................................ 136
44
1 DECLARATION OF CONFORMITY
2SAFETY
WARNING !
ARC WELDING AND CUTTING CAN BE INJURIOUS TO YOURSELF AND OTHERS. TAKE
PRECAUSIONS WHEN WELDING. FOLLOW SAFETY INSTRUCTIONS OBLIGATORY IN A COMPANY,
PREPARED ACCORDING TO EQUIPMENT MANUFACTURER’S RECOMMENDATIONS.
ELECTRIC SHOCK – can kill
Install equipment in accordance with obligatory standards.
Do not touch live electrical parts with bare skin, wet gloves or wet clothes.
Ensure your work position is safe.
FUMES AND GASES – can be dangerous to your health.
Keep your head away from fumes.
Use ventilation and/or extraction to keep fumes and gases away from your breathing zone and
surroundings.
ARC RAYS – can injure eyes and skin.
Protect your eyes and skin. Use suitable welding screens, filter lens and wear protective clothes.
Protect bystanders with suitable screens or curtains.
FIRE HAZARD
Sparks (spatter) can cause fire. Therefore make sure there are no inflammable materials nearby.
INAPPROPRIATE OPERATION OF EQUIPMENTif unit operates in a faulty way, consult a trained
technician.
READ AND COMPREHEND THE INSTRUCTION MANUAL BEFORE
INSTALLING AND OPERATING UNIT
PROTECT YOURSELF AND OTHERS!
DECLARATION OF CONFORMITY
ESAB AB Arc Equipment, S-695 81 Laxå, Sweden, gives its unreserved guarantee that welding
rectifier LKB 400W/LKB 400WS from serial number 032 complies with standard IEN 60974-1, in
accordance with the requirements of directive (73/23/EEC) and addendum (93/68/EEC) and with
standard
EN 50199, in accordance with the requirements of directive (89/336/EEC) and addendum
(93/68/EEC).
----------------------------------------------------------------------------------------------------------------------------------
Laxå 2002-03-26
Henry Selenius
Managing Director
ESAB AB Arc Equipment
695 81 Laxå
Sweden Tel: +46 584 81 000 Fax: +46 584 411924
45
3 INTRODUCTION
The LKB 400W/LKB 400WS is step-switched welding power unit, intended for welding with solid filler
wires of steel, stainless steel or aluminium, and cored wires with or without shielding gas. The LKB 400W
is equipped with cooling liquid system of torch. The LKB 400 is not equipped with cooling liquid system of
torch and can operate only with torches cooled with shield gas.
3.1 TECHNICAL DATA
Standard delivery:
Power source equipped with adjustable burnback time.
Wire feed mechanism with feed roller for solid wire diameter 1,0 – 1,2.
Welding torch PSF 410W, 4,5m.
Return cable 5m.
Mains cable 5m and gas hose 1,5m.
Set includes: chain, cable strip for gas hose.
Mains voltage 400V-415V 3~
50/60Hz
230V 3~ 50Hz
Mains fuse 25 A delayed 35 A delayed
Rated power consumption 18,8 kVA
Rated primary current for P35% 26 A 45 A
Rated welding current Duty cycle* 35% 400 A
Duty cycle* 100% 237 A
Welding current range
30÷400A
Open circuit voltage
14÷47V
Dimensions Length
Width
Height
1100
630
845
Weight 215 kg
Working flow of cooling liquid at pressure of 2,5 bar 1 dm
3
/min (60l/h)
Selection of cooling liquid depending on ambient
temperature
- Distilled water
- Solution of 30% Antifreeze Coolant + 70% distilled
water
from 0°C to +40°C
from -10°C to 0
o
C
Tank capacity 6 dm
3
Warning:
The unit is characterised by the following:
- Enclosure class IP 23 indicates that the unit is designed for indoor and outdoor use.
- Application class S means that the unit is designed for use in areas of increased electric hazard.
46
4 INSTALLATION
Installation shall be executed by competent and authorised person.
Connect the mains cable and protect it with appropriate fuse in conformance with local regulations.
Unit must be protected from dust, dirt and overheating. A distance of minimum 300 mm must be kept
between the LKB 400W/LKB 400WS and other obstacles that may block air-flow through the unit.
4.1 MAINS SUPPLY
Voltage 400V-415V
3~ 50/60 Hz
230V
3~ 50 Hz
Rated primary current:
100% Duty cycle 16A 28A
35% Duty cycle 26A 45A
Mains cable cross-section 4x4mm² 4x10mm²
Fuse, slow-blow 25A 35A
4.2 UNPACKING
A. Unpack the equipment and check that there is no obvious damage. Notify the supplier (distributor) if
any faults or damage are apparent.
B. Check if no parts are left in packing before disposal.
C. Check if all ventilation openings are opened and unblocked.
4.3 FILLING TANK WITH COOLING LIQUID
Fill cooling system tank with cooling liquid. Correct level of cooling liquid is marked with a symbol
, on
the back panel of the unit.
Depending on ambient temperature cooling liquid shall be:
- Distilled water at temperature 0°C to +40°C
- solution 30% Antifreeze Coolant (glycol based) and 70% distilled water at temperature from -10°C to
0
o
C
4.4 GAS HEATER CONNECTING
If CO
2
gas heater applied:
- insert cable of gas heater through opening on back panel of the unit
- connect cable to terminals 5,6 of terminal block XGM assembled to back panel inside the unit (symbol
GAS HEATER)
47
5 OPERATION
5.1 CONTROLS AND INDICATORS LKB 400W.
Fig. 5-1. LKB 400W front panel view.
A. POWER ON/OFF SWITCH Turning this switch to “I” position applies power to the unit. The green
LED diode (pos. B) will illuminate indicating that power is supplied to the equipment. The cooling fan
and pump engine will also be switched on. The green LED diode (pos. C) illuminates indicating
correct liquid circulation in installation. Pump is switched off 5 minutes after welding process has been
stopped. After another 5-minute period cooling fan is switched off and unit turns into stand-by mode.
It will be indicated by illuminating of the yellow LED diode (pos. B). After welding process has been
resumed, fan and pump will be activated automatically.
WARNING: If pump emits irregular noises, it signifies presence of air inside. In such a case unit
must be switched off and immediately switched on again.
48
B. OPERATION INDICATOR - diode indicating that unit is on (green colour) or in stand-by mode (yellow
colour)
C. COOLING INDICATOR - diode indicating correct circulation of cooling liquid (green colour)
D. WELDING VOLTAGE ADJUSTMENT is carried out by means of 5 position switch of coarse control
and a fine control 7 position switch. It is therefor possible to select 35 different welding voltage
outputs.
WARNING: Operating these voltage switches during the welding process (loaded power source) can
cause damage to unit!
E. OVERHEATING The orange signal LED diode (E) will illuminate in the event of overheating. The
welding output is then automatically disabled until the LKB reaches normal temperature. Should this
indicator illuminate leave the power source a few minutes to cool down. The unit will be ready to
resume welding when the orange indicator has turned off.
F. DIGITAL METER indicates actual values of welding current and voltage. The toggle switch allows
you to select either voltage or current display. The LKB 400W is supplied without a meter. The meter
kit is supplied as an optional extra and has a last reading hold facility.
G. POTENTIOMETER to set wire feeding speed (in the range of 1,6 ÷ 25 m/min)
H. CONNECTION (Euro connection) to connect welding torch
I. CURRENT SOCKETS to connect current cable with clamp
J. CONNECTION PIPE for cooling liquid outlet (cold liquid)
K. CONNECTION PIPE for cooling liquid inlet (hot liquid)
Fig.5-2. View of control panel in wire feeder compartment of LKB 400W.
L. POTENTIOMETER of burnback time regulation
M. MODE SELECTOR 2-stroke – motor test – 4-stroke
49
50
5.2 CONTROLS AND INDICATORS LKB 400WS.
Fig. 5-3. LKB 400WS front panel view.
A. POWER ON/OFF SWITCH Turning this switch to “I” position applies power to the unit. The green
LED diode (pos. B) will illuminate indicating that power is supplied to the equipment. The cooling fan
and pump engine will also be switched on. The green LED diode (pos. C) illuminates indicating
correct liquid circulation in installation. Pump is switched off 5 minutes after welding process has been
stopped. After another 5-minute period cooling fan is switched off and unit turns into stand-by mode.
It will be indicated by illuminating of the yellow LED diode (pos. B). After welding process has been
resumed, fan and pump will be activated automatically.
WARNING: If pump emits irregular noises, it signifies presence of air inside. In such a case unit
must be switched off and immediately switched on again.
B. OPERATION INDICATOR - diode indicating that unit is on (green colour) or in stand-by mode (yellow
colour)
C. COOLING INDICATOR - diode indicating correct circulation of cooling liquid (green colour)
51
D. WELDING VOLTAGE ADJUSTMENT is carried out by means of 5 position switch of coarse control
and a fine control 7 position switch. It is therefor possible to select 35 different welding voltage
outputs.
WARNING: Operating these voltage switches during the welding process (loaded power source) can
cause damage to unit!
E. OVERHEATING The orange signal LED diode (E) will illuminate in the event of overheating. The
welding output is then automatically disabled until the LKB reaches normal temperature. Should this
indicator illuminate leave the power source a few minutes to cool down. The unit will be ready to
resume welding when the orange indicator has turned off.
F. DIGITAL METER displays thickness of workpiece for voltage selected by means of switches D. Unit
adjusts suitable welding parameters for selected voltage. It also displays wire feed speed and
prospective or actual value of current/voltage (actual values of U/I are displayed during welding
process!) Toggle switches allow you to select required value. The meter has a last reading hold
facility.
G. POTENTIOMETER to set wire feeding speed (in the range of 1,6 ÷ 25 m/min)
H. CONNECTION (Euro connection) to connect welding torch
I. CURRENT SOCKETS to connect current cable with clamp
J. CONNECTION PIPE for cooling liquid outlet (cold liquid)
K. CONNECTION PIPE for cooling liquid inlet (hot liquid)
L. INDICATORS ( 3 x LED) for proper selection of the current outlet inductance
M. INDICATOR of the synergy control status:
- red light when operation prohibited (control function disabled),
- green light continuous – correct parameters for work,
Fig.5-4. View of control panel in wire feeder compartment of LKB 400WS.
N. MODE SELECTOR 2-stroke – motor test – 4-stroke
O. POTENTIOMETER of burnback time regulation
P. POTENTIOMETER for presetting of the filler wire diameter
R. CONTROL MODE SELECTOR - “standard” – (i.e. SYNERGY OFF) or “Synergy” control; for
“synergy” – allows to select data of the filler wire material and shielding gas.
52
6 MAINTENANCE
WARNING: All guarantee obligations of producer are nullified if customer attempts to repair any
faults by himself.
6.1 CLEANING
The LKB 400W/LKB 400WS should be regularly blown down with dry, compressed air at a low pressure.
If unit is used in dirty or dusty environment it shall be cleaned more often. Otherwise ventilation openings
can be blocked which can result in overheating.
7 SPARE PARTS ORDERING
When ordering spare parts, please state machine type, serial number, designation and spare part number
as shown in spare parts list. It will simplify dispatch and ensure you get the right part
8 ACCESORIES
V/A meter kit: 0349 302 118
8.1 V/A METER ALLEMBLY INSTRUCTION
1. Take off side panels of unit.
2. Put plastic sleeve on the axle of switch on meter’s board.
3. Fasten meter’s board and sleeve to front panel of unit.
4. Assemble cover of meter to partition of unit.
5. Disconnect current cable (+) from the bridge.
6. Connect shunt with reducing sleeve and rectifier bridge, and next connect current cable (+) to free
end of shunt.
7. Connect wiring of meter according to schematic diagram of LKB 400W
1. Meter A3
2. Shunt
3. Wiring for transformer T2
4. Wiring for PCB A2
5. Wiring for shunt and socket (
)
6. Rectifier bridge
7. PCB A3
8. Current cable (+)
9. Transformer T2
10. Socket (
)
53
The brake hub
The hub is adjusted when delivered, if readjustment is required, follow the instructions below. Adjust the
brake hub so that wire is slightly slack when wire feed stops.
Adjusting the braking torque:
WARNING!
Rotating parts can cause injury, take great care.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13

ESAB LKB 400W, LKB 400WS User manual

Category
Welding System
Type
User manual
This manual is also suitable for

ESAB LKB 400W, LKB 400WS is a step-switched welding power source for solid or cored wires with or without shielding gas. It allows welding with steel, stainless steel, and aluminum. The LKB 400W has a built-in cooling system for the welding torch, while the LKB 400WS does not. Both models feature adjustable burnback time, various welding voltage outputs, and overheating protection. An optional digital meter displays welding current and voltage.

Ask a question and I''ll find the answer in the document