Lenovo Flex System x220 Installation and Service Manual

  • Hello! I am an AI chatbot trained to assist you with the Lenovo Flex System x220 Installation and Service Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
FlexSystemStorageExpansionNode
InstallationandServiceGuide
Note
Beforeusingthisinformationandtheproductitsupports,readthegeneralinformationinAppendixB
“Notices”onpage51,theWarrantyInformationdocument,andtheSafetyInformationandtheEnvironmental
NoticesandUserGuidedocumentsontheproductDocumentationCD.
FirstEdition(May2015)
©CopyrightLenovo2014,2015.
LIMITEDANDRESTRICTEDRIGHTSNOTICE:IfdataorsoftwareisdeliveredpursuantaGeneralServicesAdministration
“GSAcontract,use,reproduction,ordisclosureissubjecttorestrictionssetforthinContractNo.GS-35F-05925
Contents
Safety.................iii
Safetystatements..............iv
Chapter1.Introduction.........1
Featuresandspecifications...........1
Supportedcomputenodes...........2
Majorcomponentsofthestorageexpansionnode..2
Systemboard..............3
Interposercable.............4
Drivedrawer...............4
Controlpanel..............5
Noticesandstatementsinthisdocument.....5
Chapter2.Installingthestorage
expansionnode.............7
Installationguidelines.............7
Systemreliabilityguidelines.........7
Handlingstatic-sensitivedevices......8
Removingthecoverfromthestorageexpansion
node...................8
Installingthecomputenode..........9
Removingthecomputenodefromthestorage
expansionnodeassembly..........10
Installingaflash/RAIDadapterandflashpower
module.................11
Completingtheinstallation..........13
Installingthecoveronthestorageexpansion
node.................13
Installingthestorageexpansionnodeinan
FlexSystemEnterpriseChassis......14
Updatingthecomputenodeconfiguration..15
ConfiguringtheRAIDcontroller......15
Installingahot-swapdrive..........16
Removingthestorageexpansionnodeassembly
fromtheFlexSystemEnterpriseChassis....17
Chapter3.Partslisting-storage
expansionnode............19
Chapter4.Troubleshooting......21
Eventmessages..............21
Connectionfailure.............21
Lightpathdiagnostics............22
Chapter5.Removingandreplacing
components..............25
Installationguidelines............25
Systemreliabilityguidelines........25
Handlingstatic-sensitivedevices.....26
Returningadeviceorcomponent.....26
Removingandreplacingstructuralparts....26
Removingthecoverfromthestorage
expansionnode............26
Installingthecoveronthestorageexpansion
node.................27
Removingthecamhandle........27
Replacingthecamhandle........28
Removingtheexpansionshelf.......29
Replacingtheexpansionshelf.......31
Removingthecontrolpanelassembly....33
Replacingthecontrolpanelassembly....34
Removingthebezel...........34
Replacingthebezel...........35
Removingtherearbulkhead.......35
Replacingtherearbulkhead.......37
RemovingandreplacingTier1customer
replaceableunits(CRUs)...........38
Removingtheflash/RAIDadapter.....38
Replacingtheflash/RAIDadapter.....39
Removingtheflashpowermodule.....40
Replacingtheflashpowermodule.....41
Removingthestorageexpansionnodefrom
theexpansionshelf...........42
Replacingthestorageexpansionnode...44
Removingahot-swapdrive........45
Replacingahot-swapdrive........46
AppendixA.Gettinghelpand
technicalassistance.........47
Beforeyoucall...............47
Usingthedocumentation..........48
GettinghelpandinformationfromtheWorldWide
Web...................48
HowtosendDSAdata...........48
Creatingapersonalizedsupportwebpage...48
Softwareserviceandsupport.........48
Hardwareserviceandsupport........49
Taiwanproductservice...........49
AppendixB.Notices..........51
Trademarks................52
Importantnotes..............52
Recyclinginformation............52
Particulatecontamination..........53
Telecommunicationregulatorystatement....53
Electronicemissionnotices..........53
©CopyrightLenovo2014,and2012,2015
i
FederalCommunicationsCommission(FCC)
statement...............53
IndustryCanadaClassAemissioncompliance
statement...............54
Avisdeconformitéàlaréglementation
d'IndustrieCanada...........54
AustraliaandNewZealandClassA
statement...............54
EuropeanUnionEMCDirectiveconformance
statement...............54
GermanyClassAstatement.......54
JapanVCCIClassAstatement......55
JapanElectronicsandInformationTechnology
IndustriesAssociation(JEITA)statement...55
KoreaCommunicationsCommission(KCC)
statement...............56
RussiaElectromagneticInterference(EMI)
ClassAstatement...........56
People'sRepublicofChinaClassAelectronic
emissionstatement...........56
TaiwanClassAcompliancestatement...56
Index..................57
iiFlexSystemStorageExpansionNodeInstallationandServiceGuide
Safety
Beforeinstallingthisproduct,readtheSafetyInformation.
Antesdeinstalaresteproduto,leiaasInformaçõesdeSegurança.
Læssikkerhedsforskrifterne,førduinstallererdetteprodukt.
Leesvoordatuditproductinstalleerteerstdeveiligheidsvoorschriften.
Ennenkuinasennattämäntuotteen,lueturvaohjeetkohdastaSafetyInformation.
Avantd'installerceproduit,lisezlesconsignesdesécurité.
VorderInstallationdiesesProduktsdieSicherheitshinweiselesen.
Primadiinstallarequestoprodotto,leggereleInformazionisullaSicurezza.
Lessikkerhetsinformasjonen(SafetyInformation)førduinstallererdetteproduktet.
©CopyrightLenovo2014,and2012,2015
iii
Antesdeinstalaresteproduto,leiaasInformaçõessobreSegurança.
Antesdeinstalaresteproducto,lealainformacióndeseguridad.
Lässäkerhetsinformationeninnanduinstallerardenhärprodukten.
Safetystatements
Thesestatementsprovidethecautionanddangerinformationthatisusedinthisdocumentation.
Important:Eachcautionanddangerstatementinthisdocumentationislabeledwithanumber.Thisnumber
isusedtocrossreferenceanEnglish-languagecautionordangerstatementwithtranslatedversionsofthe
cautionordangerstatementintheSafetyInformationdocument.
Forexample,ifacautionstatementislabeled“Statement1,translationsforthatcautionstatementareinthe
SafetyInformationdocumentunder“Statement1.
Besuretoreadallcautionanddangerstatementsinthisdocumentationbeforeyouperformtheprocedures.
Readanyadditionalsafetyinformationthatcomeswithyoursystemoroptionaldevicebeforeyouinstall
thedevice.
Statement1
DANGER
Electricalcurrentfrompower,telephone,andcommunicationcablesishazardous.
Toavoidashockhazard:
Donotconnectordisconnectanycablesorperforminstallation,maintenance,orreconfiguration
ofthisproductduringanelectricalstorm.
Connectallpowercordstoaproperlywiredandgroundedelectricaloutlet.
Connecttoproperlywiredoutletsanyequipmentthatwillbeattachedtothisproduct.
ivFlexSystemStorageExpansionNodeInstallationandServiceGuide
Whenpossible,useonehandonlytoconnectordisconnectsignalcables.
Neverturnonanyequipmentwhenthereisevidenceoffire,water,orstructuraldamage.
Disconnecttheattachedpowercords,telecommunicationssystems,networks,andmodems
beforeyouopenthedevicecovers,unlessinstructedotherwiseintheinstallationand
configurationprocedures.
Connectanddisconnectcablesasdescribedinthefollowingtablewheninstalling,moving,or
openingcoversonthisproductorattacheddevices.
ToConnect:ToDisconnect:
1.TurneverythingOFF.
2.First,attachallcablestodevices.
3.Attachsignalcablestoconnectors.
4.Attachpowercordstooutlet.
5.TurndeviceON.
1.TurneverythingOFF.
2.First,removepowercordsfromoutlet.
3.Removesignalcablesfromconnectors.
4.Removeallcablesfromdevices.
Statement3
CAUTION:
Whenlaserproducts(suchasCD-ROMs,DVDdrives,fiberopticdevices,ortransmitters)are
installed,notethefollowing:
Donotremovethecovers.Removingthecoversofthelaserproductcouldresultinexposureto
hazardouslaserradiation.Therearenoserviceablepartsinsidethedevice.
Useofcontrolsoradjustmentsorperformanceofproceduresotherthanthosespecifiedherein
mightresultinhazardousradiationexposure.
DANGER
SomelaserproductscontainanembeddedClass3AorClass3Blaserdiode.Notethefollowing.
Laserradiationwhenopen.Donotstareintothebeam,donotviewdirectlywithoptical
instruments,andavoiddirectexposuretothebeam.
©CopyrightLenovo2014,and2012,2015
v
Statement12
CAUTION:
Thefollowinglabelindicatesahotsurfacenearby.
Statement21
CAUTION:
Hazardousenergyispresentwhenthebladeisconnectedtothepowersource.Alwaysreplacethe
bladecoverbeforeinstallingtheblade.
ThisdeviceisforuseonlywithListedFlexSystemEnterpriseChassis.
viFlexSystemStorageExpansionNodeInstallationandServiceGuide
Chapter1.Introduction
TheLenovoFlexSystemStorageExpansionNodeisacaptive-modestorageenclosurethatisdedicatedtoa
singlecomputenodeintheLenovoFlexSystemEnterpriseChassis.
ThestorageexpansionnodeisPCIeGeneration3andSAS2.1compliant.Itsupportsupto12SASand
SATA2.5-inchhot-swapharddiskdrivesandsolid-statedrives,anditsupportsJBODconfigurationsand
RAID0,1,5,6,10,50,and60.SomeRAIDconfigurationsrequireaFeaturesonDemandkey,anoptional
512MBor1GBflash/RAIDadapter,orboth.
ThestorageexpansionnodeissupportedinanFlexSystemEnterpriseChassisonly,anditmustbeattached
toa1-bayX-Architecturecomputenode.Forinformationaboutsupportedcomputenodesandsupport
requirements,see“Supportedcomputenodes”onpage2
.
Attention:Beforeyouconnectacomputenodetothestorageexpansionnode,youmustmakesurethat
theintegratedmanagementmoduleII(IMM2)primaryandbackupfirmwareinthecomputenodeisat
levelibm_fw_imm2_1aoo34x-1.xx_anyos_noarchorlater.IftheIMM2firmwareinthecomputenodeisat
anearlierlevelwhenyouconnectthecomputenodetothestorageexpansionnode,thefirmwareinthe
storageexpansionnodewillbecomecorruptedandunrecoverable,andyouwillhavetoreplacethestorage
expansionnode.Forinformationaboutupdatingthefirmwareinthecomputenode,seethecomputenode
InstallationandServiceGuide.
Thisdocumentationprovidesthefollowinginformationaboutsettingupandtroubleshootingthestorage
expansionnode:
InstallingthestorageexpansionnodeintheFlexSystemEnterpriseChassis
Installinganoptionalflash/RAIDadapteranddrivesinthestorageexpansionnode
Diagnosingproblems
Installing,removing,andreplacingcomponents
Thestorageexpansionnodecomeswithalimitedwarranty.Forinformationaboutthetermsofthewarranty,
seetheWarrantyInformationdocumentforyourstorageexpansionnode.Thisdocumentisavailableonthe
productDocumentationCD.
Youcanobtainup-to-dateinformationaboutthestorageexpansionnodeathttp://www.ibm.com/systems.
Thestorageexpansionnodemighthavefeaturesthatarenotdescribedinthedocumentationthatcomes
withtheproduct.Thedocumentationmightbeupdatedoccasionallytoincludeinformationaboutthose
features.Technicalupdatesmightalsobeavailabletoprovideadditionalinformationthatisnotincludedin
thestorageexpansionnodedocumentation.Toobtainthelatestandmostup-to-datedocumentationfor
thisproduct,gototheLenovoproductwebsite.
Youcansubscribetoinformationupdatesthatarespecifictoyourcomputenodeat
http://www.ibm.com/support/mynotifications.
Featuresandspecifications
UsethistabletoviewspecificinformationabouttheFlexSystemStorageExpansionNode,suchas
hardwarefeaturesandthedimensionsofthestorageexpansionnode.
ThefollowingtableisasummaryofthefeaturesandspecificationsoftheFlexSystemStorageExpansion
Node.
©CopyrightLenovo2014,and2012,2015
1
Integratedfunctions:
Captive-modeconnectivitybyan
interposercabletoanFlexSystem
1-bayX-Architecturecompute
node.Forsupportrequirements,
see“Supportedcomputenodes”
onpage2
.
PCIe3.0RAIDcontroller,based
onLSISAS2208PCIeSAS/SATA
processorchip
Lightpathdiagnostics
Supportedconfigurations:
JBOD
RAID0,1,5,6,10,50,and60
SomeRAIDconfigurationsrequire
aFeaturesonDemandkey,an
optional512MBor1GBflash/RAID
adapter,orboth.
Optionaldevices:
Supportsupto12SASandSATA
2.5-inchhot-swapharddiskdrive
andsolid-statedrives
Supportsa512MBor1GB
flash/RAIDadapterandflash
powermodule
Size:
Height:55.5mm(2.19in.)
Depth:503.9mm(19.84in.)
Width:229.1mm(9.02in.)
Weight*:
Storageexpansionnodewithout
drives:6.12kg(13.5lb)
Storageexpansionnodewithout
drives,attachedtoexpansionshelf:
9.53kg(21.0lb)
Storageexpansionnodeassembly
withoutdrives,includingcompute
node:17.46kg(38.5lb)
Storageexpansionnodeassembly
with12drives,includingcompute
node:21.09kg(46.5lb)
*Weightsareapproximateanddependonthetypesofinstalleddrivesandthehardwareconfigurationofthecompute
node.
Supportedcomputenodes
Thestorageexpansionnodemustbeattachedtoa1-bayX-Architecturecomputenode.
Attention:Beforeyouconnectacomputenodetothestorageexpansionnode,youmustmakesurethat
theintegratedmanagementmoduleII(IMM2)primaryandbackupfirmwareinthecomputenodeisat
levelibm_fw_imm2_1aoo34x-1.xx_anyos_noarchorlater.IftheIMM2firmwareinthecomputenodeisat
anearlierlevelwhenyouconnectthecomputenodetothestorageexpansionnode,thefirmwareinthe
storageexpansionnodewillbecomecorruptedandunrecoverable,andyouwillhavetoreplacethestorage
expansionnode.Forinformationaboutupdatingthefirmwareinthecomputenode,seethecomputenode
InstallationandServiceGuide.
Somecomputenodesrequiretwoinstalledmicroprocessorstosupportconnectiontothestorageexpansion
node.
Asofthedateofthispublication,thestorageexpansionnodesupportsthefollowingFlexSystemcompute
nodes:
x220(requirestwoinstalledmicroprocessors)
x240(requirestwoinstalledmicroprocessors)
Majorcomponentsofthestorageexpansionnode
Usethisinformationtoidentifythemajorcomponentsofthestorageexpansionnode.
Thefollowingillustrationshowsthemajorcomponentsofthestorageexpansionnode.
2FlexSystemStorageExpansionNodeInstallationandServiceGuide
Systemboard
Thesystemboardexecutesallthemajorlogicfunctionsofthestorageexpansionnode.
Thefollowingillustrationshowsthelocationsofthecomponentsonthesystemboard.
Flash/RAIDadapterconnector
Thestorageexpansionnodesupportsanoptional512MBor1GBflash/RAIDadapter.
Chapter1.Introduction3
LightpathdiagnosticsLEDsandlightpathbutton
LightpathdiagnosticsisasystemofLEDsinthestorageexpansionnodeandtheattachedcompute
nodethatyoucanusetodiagnoseproblems.Formoreinformation,see“Lightpathdiagnostics”
onpage22
.
Interposercable
Theinterposercableconnectsthestorageexpansionnodetothecomputenode.
Thestorageexpansionnodecomeswithaninterposercablethatisconnectedtothesystemboard.Thefree
endofthecableexitsthestorageexpansionnodeneartheleft-rearcorner.Afteryouattachacompute
nodetotheexpansionshelf,youconnectthefreeendoftheinterposercabletotheinterposerconnector
onthecomputenodesystemboardtoestablishtheconnectionbetweenthestorageexpansionnode
andthecomputenode.
Drivedrawer
Thedrivedrawerinthestorageexpansionnodecontains12hot-swapdrivebays.
Thedraweraccommodatesupto12hot-swapSASorSATA2.5-inchharddiskdrivesorsolid-statedrives.
Thedrivedraweralsohasabracketfortheflashpowermodulethatisusedwithanoptionalflash/RAID
adapter.
Thefollowingillustrationshowsthelayoutofthedrivebaysinthedrawer.
Attention:
Toensurepropercoolingandprotectsystemdataintegrity,donotoperatethestorageexpansionnode
foranextendedperiodoftimewiththedraweropen.Keepthedrivedrawerclosedwhenyouarenot
installingorremovingdrives.
Makesurethatthedrivedrawerissupportedwhenitisopen.Theweightofinstalleddrivescancausethe
storageexpansionnodeassemblytobeunstablewhenthedrivedrawerisopen.
Toopenthedrawer,pulloutonthehandleandpullthedrawerout,asshowninthefollowingillustration.
4FlexSystemStorageExpansionNodeInstallationandServiceGuide
Toclosethedrawer,pushthedrawerinuntilitstops,andreturnthehandletotheclosedposition.
Controlpanel
ThecontrolpanelonthestorageexpansionnodehasagreenactivityLEDforeachdrivebay,oneyellow
statusLEDforallthedrivebays,andadrawer-openLED.
ThefollowingillustrationshowstheLEDsonthecontrolpanel.
ActivityLEDs(green)
WhenoneoftheseLEDsislit,itindicatesactivityonthedriveintheassociateddrivebay.
StatusLED(yellow)
ThestatusLEDgivesthefollowingindications:
Lit:Oneormoredrivesareinafaultstate.
Flashing:Oneormoredrivesarebeingidentified.
Flashingandthenlit:Oneormoredrivesareinafaultstateandarebeingidentified.TheLEDflashes
untilidentificationiscomplete,andthentheLEDremainslituntilallfaultstateshavebeenresolved.
Drawer-openLED
Ifthestorageexpansionnodeisoperatedfortoolongwiththedraweropen,thechassiscoolingfans
mightincreaseinspeed,andthestorageexpansionnodemightpoweroff.Ifthedrawerisopen,the
drawer-openLEDflashesandanaudiblebeepsoundstogivethefollowingindications:
Every15seconds:Thedrawerisnotfullyclosed.Closethedrawerwhenyouhavefinishedinstalling
orremovingdrives.
Every5seconds:Thedrawerhasbeenopentoolong.Closethedrawerimmediately.
Every0.25second:Thestorageexpansionnodehasreacheditsthermalthreshold.Closethe
drawerimmediatelytoavoiddamagetothedrives.
Noticesandstatementsinthisdocument
Usethisinformationtounderstandthemostcommondocumentationnoticesandstatementsandhow
theyareused.
ThecautionanddangerstatementsinthisdocumentarealsointhemultilingualSafetyInformation
document,whichisontheproductDocumentationCD.Eachstatementisnumberedforreferencetothe
correspondingstatementintheSafetyInformationdocument.
Thefollowingnoticesandstatementsareusedinthisdocument:
Chapter1.Introduction5
Note:Thesenoticesprovideimportanttips,guidance,oradvice.
Important:Thesenoticesprovideinformationoradvicethatmighthelpyouavoidinconvenientor
problemsituations.
Attention:Thesenoticesindicatepossibledamagetoprograms,devices,ordata.Anattentionnoticeis
placedjustbeforetheinstructionorsituationinwhichdamagemightoccur.
Caution:Thesestatementsindicatesituationsthatcanbepotentiallyhazardoustoyou.Acaution
statementisplacedjustbeforethedescriptionofapotentiallyhazardousproceduresteporsituation.
Danger:Thesestatementsindicatesituationsthatcanbepotentiallylethalorhazardoustoyou.A
dangerstatementisplacedjustbeforethedescriptionofapotentiallylethalorhazardousprocedure
steporsituation.
6FlexSystemStorageExpansionNodeInstallationandServiceGuide
Chapter2.Installingthestorageexpansionnode
Thestorageexpansionnodecomesattachedtotheexpansionshelf.Usetheseinstructionstoinstalla
computenodeontheshelf,installanoptionalflash/RAIDadapterandflashpowermodule,andinstallthe
storageexpansionnodeassemblyinanFlexSystemEnterpriseChassis.
Attention:Beforeyouconnectacomputenodetothestorageexpansionnode,youmustmakesurethat
theintegratedmanagementmoduleII(IMM2)primaryandbackupfirmwareinthecomputenodeisat
levelibm_fw_imm2_1aoo34x-1.xx_anyos_noarchorlater.IftheIMM2firmwareinthecomputenodeisat
anearlierlevelwhenyouconnectthecomputenodetothestorageexpansionnode,thefirmwareinthe
storageexpansionnodewillbecomecorruptedandunrecoverable,andyouwillhavetoreplacethestorage
expansionnode.Forinformationaboutupdatingthefirmwareinthecomputenode,seethecomputenode
InstallationandServiceGuide.
Installationguidelines
Usetheseguidelinesbeforeyouinstallthestorageexpansionnodeoroptionaldevices.
Beforeyoubegin,read“Safety”onpageiiiand“Handlingstatic-sensitivedevices”onpage8.This
informationwillhelpyouworksafely.
Beforeyouinstallyournewstorageexpansionnode,taketheopportunitytodownloadandapplythe
mostrecentfirmwareupdatestotheassociatedcomputenode.Thisstepwillhelptoensurethatany
knownissuesareaddressedandthatyoursystemisreadytofunctionatmaximumlevelsofperformance.
Attention:Beforeyouconnectacomputenodetothestorageexpansionnode,youmustmakesure
thattheintegratedmanagementmoduleII(IMM2)primaryandbackupfirmwareinthecomputenodeis
atlevelibm_fw_imm2_1aoo34x-1.xx_anyos_noarchorlater.IftheIMM2firmwareinthecomputenode
isatanearlierlevelwhenyouconnectthecomputenodetothestorageexpansionnode,thefirmware
inthestorageexpansionnodewillbecomecorruptedandunrecoverable,andyouwillhavetoreplace
thestorageexpansionnode.Forinformationaboutupdatingthefirmwareinthecomputenode,see
thecomputenodeInstallationandServiceGuide.
Observegoodhousekeepingintheareawhereyouareworking.Placeremovedcoversandotherparts
inasafeplace.
Backupallimportantdatabeforeyoumakechangestodiskdrives.
BeforeyouremoveacomputenodefromtheFlexSystemEnterpriseChassis,youmustshutdownthe
operatingsystemandturnoffthecomputenode.Youdonothavetoshutdownthechassisitself.
Blueonacomponentindicatestouchpoints,whereyoucangripthecomponenttoremoveitfromor
installitinthecomputenode,openorclosealatch,andsoon.
Orangeonacomponentoranorangelabelonornearacomponentindicatesthatthecomponentcan
behot-swapped,whichmeansthatifthecomputenodeandoperatingsystemsupporthot-swap
capability,youcanremoveorinstallthecomponentwhilethecomputenodeisrunning.(Orangecan
alsoindicatetouchpointsonhot-swapcomponents.)Seetheinstructionsforremovingorinstallinga
specifichot-swapcomponentforanyadditionalproceduresthatyoumighthavetoperformbefore
youremoveorinstallthecomponent.
Foralistofsupportedoptionaldevicesforthecomputenode,see
http://www.ibm.com/systems/info/x86servers/serverproven/compat/us.
Systemreliabilityguidelines
Usetheseguidelinestoensurethatthestorageexpansionnodemeetsthecoolingandsystemreliability
requirements.
©CopyrightLenovo2014,and2012,2015
7
Toensurepropercooling,donotoperatetheFlexSystemEnterpriseChassiswithoutadeviceorfiller
installedineachbay.SeethedocumentationforyourFlexSystemEnterpriseChassisforadditional
information.
Makesurethattheventilationholesonthestorageexpansionnodearenotblocked.
Thecomputenodebatterymustbeoperational.Ifthebatterybecomesdefective,replaceitimmediately.
Forinstructions,seethecomputenodeInstallationandServiceGuide.
Handlingstatic-sensitivedevices
Toreducethepossibilityofdamagefromelectrostaticdischarge,observetheseprecautions.
Attention:Staticelectricitycandamagethestorageexpansionnodeandotherelectronicdevices.Toavoid
damage,keepstatic-sensitivedevicesintheirstatic-protectivepackagesuntilyouarereadytoinstallthem.
Whenyouworkonarackthathasanelectrostaticdischarge(ESD)connector,useawriststrap,especially
whenyouhandlemodules,optionaldevices,orcomputenodes.Toworkcorrectly,thewriststrapmust
haveagoodcontactatbothends(touchingyourskinatoneendandfirmlyconnectedtotheESD
connectoronthefrontorbackoftherack).
Limityourmovement.Movementcancausestaticelectricitytobuilduparoundyou.
Handlethedevicecarefully,holdingitbyitsedgesoritsframe.
Donottouchsolderjoints,pins,orexposedcircuitry.
Donotleavethedevicewhereotherscanhandleanddamageit.
Whilethedeviceisstillinitsstatic-protectivepackage,touchittoanunpaintedmetalpartoftheFlex
SystemEnterpriseChassisoranyunpaintedmetalsurfaceonanyothergroundedrackcomponentinthe
rackinwhichyouareinstallingthedeviceforatleast2seconds.Thisdrainsstaticelectricityfromthe
packageandfromyourbody.
Removethedevicefromitspackageandinstallitdirectlyintothecomputenodewithoutsettingdownthe
device.Ifitisnecessarytosetdownthedevice,putitbackintoitsstatic-protectivepackage.Donot
placethedeviceonthecomputenodecoveroronametalsurface.
Takeadditionalcarewhenyouhandledevicesduringcoldweather.Heatingreducesindoorhumidity
andincreasesstaticelectricity.
Removingthecoverfromthestorageexpansionnode
Usetheseinstructionstoremovethecoverfromthestorageexpansionnode.
Beforeyoubegin
Beforeyouremovethecoverfromthestorageexpansionnode,completethefollowingsteps:
1.Read“Safety”onpageiiiand“Installationguidelines”onpage7.
2.IfthestorageexpansionnodeassemblyisinstalledinanFlexSystemEnterpriseChassis,removeit
(see“RemovingthestorageexpansionnodeassemblyfromtheFlexSystemEnterpriseChassis”on
page17
forinstructions).
3.Carefullylaythestorageexpansionnodeassemblyonaflat,static-protectivesurface.
Procedure
Pressonthecoverreleaseandslidethecovertowardtherearofthestorageexpansionnode;then,liftthe
coverawayfromthestorageexpansionnode,asshowninthefollowingillustration.
8FlexSystemStorageExpansionNodeInstallationandServiceGuide
Installingthecomputenode
Thestorageexpansionnodecomesattachedtotheexpansionshelf.Youmustattachacomputenodetothe
expansionshelfandconnecttheinterposercabletothecomputenode.
Attention:Beforeyouconnectacomputenodetothestorageexpansionnode,youmustmakesurethat
theintegratedmanagementmoduleII(IMM2)primaryandbackupfirmwareinthecomputenodeisat
levelibm_fw_imm2_1aoo34x-1.xx_anyos_noarchorlater.IftheIMM2firmwareinthecomputenodeisat
anearlierlevelwhenyouconnectthecomputenodetothestorageexpansionnode,thefirmwareinthe
storageexpansionnodewillbecomecorruptedandunrecoverable,andyouwillhavetoreplacethestorage
expansionnode.Forinformationaboutupdatingthefirmwareinthecomputenode,seethecomputenode
InstallationandServiceGuide.
Beforeyouattachacomputenodetotheexpansionshelf,completethefollowingsteps:
1.Read“Safety”onpageiiiand“Installationguidelines”onpage7.
2.Ifthecomputenodeisinstalledandoperating,completethefollowingsteps:
a.Shutdowntheoperatingsystem,andpressthepowerbuttontoturnoffthecomputenode(seethe
computenodeInstallationandServiceGuideforinstructions).
b.RemovethecomputenodefromtheFlexSystemEnterpriseChassis(seethecomputenode
InstallationandServiceGuideforinstructions).
3.Makesurethatthecomputenodehastwomicroprocessors,ifthatconfigurationisrequiredforthe
computenodetoworkwiththestorageexpansionnode.Todeterminewhetherasupportedcompute
noderequirestwomicroprocessors,see“Supportedcomputenodes”onpage2.
4.MakesurethattheintegratedmanagementmoduleII(IMM2)primaryandbackupfirmwareisatlevel
ibm_fw_imm2_1aoo34x-1.xx_anyos_noarchorlater.
Attention:IftheIMM2firmwareinthecomputenodeisatanearlierlevelwhenyouconnectthe
computenodetothestorageexpansionnode,thefirmwareinthestorageexpansionnodewillbecome
corruptedandunrecoverable,andyouwillhavetoreplacethestorageexpansionnode.
Toattachacomputenodetotheexpansionshelf,completethefollowingsteps.
Chapter2.Installingthestorageexpansionnode9
Step1.Placethestorageexpansionnodeassemblyonaflat,static-protectivesurfacewiththestorage
expansionnodebezelfacingyou.
Step2.Removethecomputenodecover(seethecomputenodeInstallationandServiceGuidefor
instructions).
Attention:Bendtheinterposercableupandoverthestorageexpansionnodetoensurethatthe
cableandconnectorareclearoftheareawherethecomputenodewillbeattached.
Step3.Withtherightedgeofthecomputenodealignedwiththecomputenodealignmentmarkonthe
expansionshelf,orienttheslotsonthebottomofthecomputenodewiththepostsontheleft
sideoftheexpansionshelf.Then,slidethecomputenodetowardthecenteroftheshelfuntil
theretentionlatchclicksintoplace.
Step4.IfanyI/Oexpansionadaptersinthecomputenodeareblockingaccesstotheinterposerconnector,
removethem(seethecomputenodeInstallationandServiceGuideforinstructions).
Step5.Connecttheinterposercabletotheinterposerconnectoronthecomputenodesystemboard,as
showninthefollowingillustration.
Step6.IfyouremovedanyI/Oexpansionadaptersfromthecomputenode,installthem(seethecompute
nodeInstallationandServiceGuideforinstructions).
Step7.Installthecomputenodecover(seethecomputenodeInstallationandServiceGuidefor
instructions).
Removingthecomputenodefromthestorageexpansionnodeassembly
Usetheseinstructionstoremovethecomputenodefromthestorageexpansionnodeassembly.
Beforeyouremovethecomputenodefromthestorageexpansionnodeassembly,completethefollowing
steps:
10FlexSystemStorageExpansionNodeInstallationandServiceGuide
1.Read“Safety”onpageiiiand“Installationguidelines”onpage7.
2.IfthestorageexpansionnodeassemblyisinstalledinanFlexSystemEnterpriseChassis,removeit
(see“RemovingthestorageexpansionnodeassemblyfromtheFlexSystemEnterpriseChassis”on
page17
forinstructions).
3.Carefullylaythestorageexpansionnodeassemblyonaflat,static-protectivesurfacewiththestorage
expansionnodeandcomputenodebezelsfacingyou.
Toremovethecomputenode,completethefollowingsteps:
Step1.Removethecomputenodecover(seethecomputenodeInstallationandServiceGuidefor
instructions).
Step2.IfanyI/Oexpansionadaptersinthecomputenodeareblockingaccesstotheinterposerconnector,
removethem(seethecomputenodeInstallationandServiceGuideforinstructions).
Step3.Disconnecttheinterposercablefromtheinterposerconnectoronthecomputenodesystemboard.
Step4.IfyouremovedanyI/Oexpansionadaptersfromthecomputenode,installthem(seethecompute
nodeInstallationandServiceGuideforinstructions).
Step5.Ontheundersideoftheexpansionshelf,lifttheraisededgeoftheretaininglatchthatsecuresthe
computenodetotheshelfwhileyouslidethecomputenodeawayfromthecenteroftheshelf,as
showninthefollowingillustration.
Step6.Installthecomputenodecover(seethecomputenodeInstallationandServiceGuidefor
instructions).
Installingaflash/RAIDadapterandflashpowermodule
SomeRAIDconfigurationsrequireanoptional512MBor1GBflash/RAIDadapter.Theadaptercomes
withaflashpowermodule,whichyoumustinstallwiththeadapter.
Chapter2.Installingthestorageexpansionnode11
Beforeyouinstallaflash/RAIDadapterandflashpowermoduleinthestorageexpansionnode,completethe
followingsteps:
1.Read“Safety”onpageiiiand“Installationguidelines”onpage7.
2.IfthestorageexpansionnodeassemblyisinstalledinanFlexSystemEnterpriseChassis,removeit
(see“RemovingthestorageexpansionnodeassemblyfromtheFlexSystemEnterpriseChassis”on
page17
forinstructions).
3.Carefullylaythestorageexpansionnodeassemblyonaflat,static-protectivesurface.
4.Removethestorageexpansionnodecover(see“Removingthecoverfromthestorageexpansionnode”
onpage8forinstructions).
Attention:Makesurethatthedrivedrawerissupportedwhenitisopen.Theweightofinstalleddrives
cancausethestorageexpansionnodeassemblytobeunstablewhenthedrivedrawerisopen.
5.Openthedrivedrawerapproximately30cm(12in.).
6.Seetheillustrationin“Systemboard”onpage3forthelocationoftheflash/RAIDadapterconnector.
Toinstallaflash/RAIDadapterandflashpowermodule,completethefollowingsteps.
Step1.Touchthestatic-protectivepackagethatcontainstheadaptertoanyunpaintedmetalsurfaceon
theFlexSystemEnterpriseChassisoranyunpaintedmetalsurfaceonanyothergroundedrack
component;then,removetheadapterfromthepackage.
Step2.Orienttheadapterwiththeconnectoronthesystemboard;then,firmlypressontheindicated
locationontheadapteruntilthebluelatchsnapsupandovertheedgeoftheadapter.
Step3.Connectthecabletotheadapter.Theconnectorsarekeyedtopreventincorrectinsertion.
Step4.Makesurethatthecableissecuredinthecableclipontheinsidewallofthestorageexpansion
node.
Step5.Pressdownslightlyonthereleaseontheouteredgeoftheblueflashpowermodulebracketand
inserttheflashpowermoduleintothebracket,withthecableorientedtowardtheoutsideofthe
drivedrawer,asshowninthefollowingillustration.
12FlexSystemStorageExpansionNodeInstallationandServiceGuide
/