PROGRAMMING OZONE CONTROL VALVE CONTINUED
PROGRAMMING OZONE CONTROL VALVE
SETTING THE TIME
NOTES
1) Press NEXT and DOWN simultaneously
and release. Press NEXT and DOWN
Step 2 does not
appear, the lock on the valve is activated.
To unlock, press DOWN, NEXT, UP
and CLOCK in sequence, then press NEXT
and DOWN
and release. Press NEXT and DOWN
2)
Press CLOCK once. Press UP or DOWN
until your hour is correct and the correct
NEXT to select
the minutes (select UP or DOWN until the
minutes are correct). Select CLOCK to get
back to the main screen.
happen while you are sleeping.
2) The Relay Actuation Time is when the
The entire process will take 37 minutes,
leaving adequate time to vent.
6)
SET
FILTERING
REGEN
Use UP or DOWN to select FILTERING
REGEN. Press NEXT to go to Step 3. Press
REGEN
3)
SET TIME
BACKWASH
MIN
1 10
SET TIME
MIN
15:00
SET TIME
MIN
37:00
Use UP or DOWN to adjust backwash
time (we suggest 10 minutes). Press NEXT
to go to Step 4. Press REGEN to return to
previous step.
4)
SET
SET
BRINE
BRINE
MIN
2 30
2 dn
Step 4 alternates between the two
displays shown. Use UP or DOWN to adjust
brine time (we suggest 30 minutes). Press
NEXT to go to Step 5. Press REGEN to
return to previous step.
5)
SET
BACKWASH
MIN
3 off
Use UP or DOWN to set RINSE to OFF. Press
NEXT to go to Step 7. Press REGEN to return
to previous step.
7)
SET
RINSE
4 off
Use UP or DOWN to set FILL to OFF. Press
NEXT to go to Step 8. Press REGEN to return
to previous step.
8)
SET
GAL
FILL
5 off
Use UP or DOWN to set REGEN to OFF.
Press NEXT to go to Step 9. Press REGEN to
return to previous step.
9)
SET
REGEN
off
Step 9 alternates between the two
displays shown. Use UP or DOWN to set
RELAY 1 to ON. Press NEXT to go to Step
10. Press REGEN to return to previous step.
10)
SET
SET
rL
y
1
0ff
Use UP or DOWN to set RELAY 1 to 15.
Press NEXT to go to Step 11. Press REGEN
to return to previous step.
11)
Use UP or DOWN to set 2nd backwash to
OFF. Press NEXT to go to Step 6. Press
REGEN to return to previous step.
Step 10 sets Relay Actuation Time, when
means the relay will turn on the EOG unit 1
REMAINING
EOG unit is activated. Use UP or DOWN to
minutes. Press NEXT to go to Step 12.
Press REGEN to return to previous step.
12)
SET
SET
rL
y
2
0ff
Step 12 alternates between the two
displays shown. Use UP or DOWN to set
RELAY 2 to OFF. Press NEXT to EXIT
REGEN to
return to previous step.