Wilkins 34-600XL Installation guide

Type
Installation guide

Wilkins 34-600XL is a water pressure reducing valve designed to protect your plumbing system from high water pressure. It features a lead-free bronze body, stainless steel trim, and a built-in strainer to remove sediment and debris. The 34-600XL is ideal for residential and commercial use, and can be installed in any position. It also has an adjustable pressure range of 25 to 75 psi, making it suitable for a variety of applications.

Wilkins 34-600XL is a water pressure reducing valve designed to protect your plumbing system from high water pressure. It features a lead-free bronze body, stainless steel trim, and a built-in strainer to remove sediment and debris. The 34-600XL is ideal for residential and commercial use, and can be installed in any position. It also has an adjustable pressure range of 25 to 75 psi, making it suitable for a variety of applications.

DOCUMENT #: REVISION:
REG-600XL 7/11
SPECIFICATION SUBMITTAL SHEET
Page 1 of 2
Model 600XL
Water Pressure Reducing Valve
with Integral By-pass Check Valve and Strainer
WILKINS a Zurn Company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766
In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292
Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com
a company
®
®
APPLICATION
Ideal for use where lead-free* valves are required. Designed
for installation on potable water lines to reduce high inlet pres-
sure to a lower outlet pressure. The integral strainer makes
this device most suitable for residential and commercial water
systems requiring frequent cleaning because of sediment and
debris. The direct acting integral by-pass design prevents
buildup of excessive system pressure caused by thermal ex-
pansion. The balanced piston design enables the regulator to
react in a smooth and responsive manner to changes in system
ow demand, while at the same time, providing protection from
inlet pressure changes.
STANDARDS COMPLIANCE
ASSE® Listed 1003
IAPMO® Listed
CSA® Certied
City of Los Angeles Approved
NSF® Listed - Standard 61, Annex G
LEAD PLUMBING LAW COMPLIANCE
*(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT)
Lead Plumbing Law Certied by IAPMO R&T
Annex G Certied by NSF International
MATERIALS
Main valve body Cast Bronze ASTM B 584
Access covers Cast Bronze ASTM B 584
Low Lead Brass
Fasteners Stainless Steel, 300 Series
Stem & plunger Cast Bronze ASTM B 584
Low Lead Brass
Elastomers Buna Nitrile, (FDA Approved)
EPDM, (FDA Approved)
Cap gaskets Natural Vulcanized Fibre
Acetal (Delrin™), NSF Listed
Strainer screen Stainless Steel, 300 Series
FEATURES
Sizes: ½" ¾" 1" 1¼" 1½" 2"
Maximum working water pressure 300 psi
Maximum working water temperature 140°F
Reduced pressure range (standard) 25 psi to 75 psi
Factory preset 50 psi
Hydrostatic test pressure 300 psi
CPVC tailpiece: Max. hot water temp. 140°F @ 100 psi
Cold water rated temp. 73.4°F @ 400 psi
OPTIONS (Sufxes can be combined)
- standard with 20 mesh strainer screen
C - copper sweat connection (3/4" thru 2")
HR - 75 psi to 125 psi spring range, factory set at 85 psi
HLR - 10 psi to 125 psi spring range, factory set at 50 psi
HTSTSC - 180°F maximum temp, stainless steel trim,
spring, sealed cage
L - less integral by-pass check valve
LU - less union assembly, female x female (3/4" & 1" only)
LPV - 140°F maximum temp with 10 psi to 35 psi
spring range, factory set at 20 psi
LPC - 180°F maximum temp with 10 psi to 35 psi
spring range, factory set at 20 psi (2” eld
set only)
SC - sealed cage bell housing and stainless steel
adjustment screw
610XL - 400 psi inlet rating and 75 psi to 125 psi
spring range, factory set at 85 psi
P - tapped and plugged for gauge
CPVC - CPVC tailpiece connection (1/2”-1”)
G - Tapped with gauge
CH - Chrome stem & plunger
DIMENSIONS & WEIGHTS (do not include pkg.)
SIZE
CONNECTIONS
DIMENSIONS (approximate)
WEIGHT
A B C D
in. mm in. mm in. mm in. mm in. mm lbs. kg.
1/2 15 SINGLE UNION 5 1/2 133 6 1/4 159 1 1/4 32 2 3/4 70 3 1.5
1/2 15 LESS UNION 4 1/2 114 6 1/4 159 1 1/4 32 2 3/4 70 3 1.5
3/4 20 SINGLE UNION 5 5/16 135 5 1/2 140 1 1/4 32 2 3/4 70 3 1.5
3/4 20 LESS UNION 4 7/8 121 5 1/2 140 1 1/4 32 2 3/4 70 3 1.5
1 25 SINGLE UNION 6 1/8 156 7 1/4 184 2 51 3 3/8 86 5 2.5
1 25 LESS UNION 5 3/4 146 7 1/4 184 2 51 3 3/8 86 5 2.5
1 1/4 32 SINGLE UNION 7 1/8 181 8 203 2 51 3 7/8 100 7 3.0
1 1/2 40 SINGLE UNION 9 1/8 232 10 254 2 1/2 64 5 127 13 6.0
2 50 SINGLE UNION 10 1/4 260 12 305 3 76 6 1/2 165 21 9.5
600XL
WILKINS
D
B
A
C
Page 2 of 2
WILKINS a Zurn Company, 1747 Commerce Way, Paso Robles, CA 93446 Phone:805/238-7100 Fax:805/238-5766
In Canada: ZURN INDUSTRIES LIMITED, 3544 Nashua Dr., Mississauga, Ontario L4V 1L2 Phone:905/405-8272 Fax:905/405-1292
Product Support Help Line: 1-877-BACKFLOW (1-877-222-5356) Website: http://www.zurn.com
DIRECTION OF FLOW
12" MIN.
30" MAX.
OPTIONAL PRESSURE
GAUGE
MODEL 975XL2
BACKFLOW PREVENTER
PROTECTIVE
ENCLOSURE
WILKINS
600XL
WILKINS
ZURN
975XL2
ASSE 1013
FLOW CHARACTERISTICS
SPECIFICATIONS
The Pressure Reducing Valve shall be ANSI 3
rd
party certied to comply with states' lead plumbing law 0.25% maximum
weighted average lead content requirement, consist of a bronze body and bell housing, shall have separate access
covers for the plunger and strainer screen and shall have a bolt to adjust the downstream pressure. The Pressure
Reducing Valve shall be of the balanced piston design and shall reduce pressure in both ow and no-ow conditions.
The bronze bell housing and access caps shall be threaded to the body and shall not require the use of ferrous screws.
The Pressure Reducing Valve shall be a WILKINS Model 600XL.
TYPICAL INSTALLATION
Local codes shall govern installation requirements. Unless otherwise specied, the assembly shall be mounted in ac-
cordance with the latest edition of the Uniform Plumbing Code. The Model 600XL may be installed in any position. If
installed in a pit, vault or inside application, specify the “SC” sealed cage option. Multiple installations are recommend
for wide demand variations or where the desired pressure reduction is more than 4 to 1 (i.e.: 200 psi inlet reduced to
50 psi outlet). CAUTION: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify
correct pressure setting. Do not bottom adjustment bolt on bell housing.
OUTDOOR INSTALLATION VERTICAL INSTALLATION
DIRECTION OF FLOW
MODEL 850XL
SHUT-OFF
600XL
WILKINS
OPTIONAL
PRESSURE GAUGE
FLOW RATES (GPM)
FALL OFF (PSIG)
0
5
10
15
04080
120
69
104
2.55.0
7.6
FALL OFF (kpa)
FLOW RATES (l/s)
MODEL 600XL 1/2" THRU 2" (STANDARD & METRIC)
3/4"
(20mm)
35
20
138
1/2"
(15mm)
1"
(25mm)
1 1/4"
(32mm)
1 1/2"
(40mm)
2"
(50mm)
20
60
100
1.3
3.8
6.3
"Flow curves are based on a
50 psi pressure differential"
  • Page 1 1
  • Page 2 2

Wilkins 34-600XL Installation guide

Type
Installation guide

Wilkins 34-600XL is a water pressure reducing valve designed to protect your plumbing system from high water pressure. It features a lead-free bronze body, stainless steel trim, and a built-in strainer to remove sediment and debris. The 34-600XL is ideal for residential and commercial use, and can be installed in any position. It also has an adjustable pressure range of 25 to 75 psi, making it suitable for a variety of applications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI