Miele 52713602USA Installation guide

Category
Electric laundry dryers
Type
Installation guide

This manual is also suitable for

Installationsplan / Installation plan
Installatietekening
Plan d`installation
Piano di installazione
Plano de instalación
Plano de instalação
Σχέδιο εγκατάστασης
Asennusohje
Installasjonsplan
Installationsplan
G
PT 7136 / PT 5136 EL
Materialnummer / Mat. no.: 06 664 260
Änderungsstand / Version: 02
Datum Zeichnung / Drawing date: 25.04.2005
Datum Legende / Legend date: 15.11.2007
Installationsplan PT 7136 / PT 5136 EL
Stand: 15.11.2007 Seite 8
Technical datasheet
Tumble dryers:
Heating:
PT 7136 / PT 5136
Electric (EL)
Legend:
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
G
Optional extras:
UG/UO 5005 Miele plinth
(UG = Box plinth/UO = Open plinth)
UM
Height Model mm 300
Width UG (UO) mm 609 (598)
Depth UG (UO) mm 622 (615)
Concrete platform Concrete platform optional (Min. quality B15)
Recommended height mm 300
BS
Minimum height mm 100
Recommended width mm 600
Recommended depth mm 650
Ensure good anchorage!
Machine connections:
1. Standard voltage (as supplied) V 3N AC 400
Frequency Hz 50
Rated load kW 6.4
Fuse rating A 3 × 10
Electrical
connection
D
Connection cable, min. cross-section mm² 5 × 1.5
Length of supply lead (H05 RN-F without plug)
(supplied)
mm 2000
1. Alternative voltage V 3 AC 230
Frequency Hz 50
Rated load kW 6.5
Fuse rating A 3 × 16
Supply lead as above
convertible
2. Alternative voltage V 1N AC 230
Frequency Hz 50
Rated load kW 3.35
Fuse rating A 1 × 16
Supply lead as above
convertible
3. Alternative voltage V 1N AC 230
Frequency Hz 50
Rated load kW 2.24
Fuse rating A 1 × 10
Supply lead as above
convertible
Country variations:
2. Standard voltage (as supplied) V 1N AC 220 - 230
Frequency Hz 50
G i
Rated load kW 5.08 – 5.52
Fuse rating A 1 × 25
Connection cable, min. cross-section mm² 3 × 2.5
Length of supply lead (H05 RN-F without plug)
(supplied)
mm 2000
Installationsplan PT 7136 / PT 5136 EL
Stand: 15.11.2007 Seite 9
3. Standard voltage (as supplied) V 3 AC 230
Frequency Hz 50
N
Rated load kW 6.4
Fuse rating A 3 × 16
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (H05 RN-F without plug)
(supplied)
mm 2000
4. Standard voltage (as supplied) V 1N AC 230-240
Frequency Hz 50
W
Rated load kW 5.52 – 6.0
Fuse rating A 1 × 25
Connection cable, min. cross-section mm² 3 × 2.5
Length of supply lead (H05 RN-F without plug)
(supplied)
mm 2000
5. Standard voltage (as supplied) V 3 AC 208
Frequency Hz 60
V U
Rated load kW 6.4
Fuse rating A 3 × 24
Connection cable, min. cross-section mm² 4 × AWG 10
Length of supply lead (H05 RN-F with plug)
(supplied)
mm 2000
Alternative voltage V 2 AC 208
Frequency Hz 60
Rated load kW 4.4
Fuse rating A 2 × 24
Supply lead as above
convertible
6. Standard voltage (as supplied) V 2N AC 200
Frequency Hz 50-60
J
Rated load kW 4.0
Fuse rating A 2 × 20
Connection cable, min. cross-section mm² 3 × 2.75
Length of supply lead (H05 RN-F with plug)
(supplied)
mm 2000
Non-standard voltages:
1. Standard voltage (as supplied) V 3 AC 230
Frequency Hz 60
OS 230
Rated load kW 6.4
Fuse rating A 3 × 16
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (H07 RN-F without plug)
(supplied)
mm 2000
2. Standard voltage (as supplied) V 3 AC 400
Frequency Hz 50
OS 400
Rated load kW 5.35
Fuse rating A 3 × 10
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (H07 RN-F without plug)
(supplied)
mm 2000
3. Standard voltage (as supplied) V 3 AC 440
Frequency Hz 60
OS 440
Rated load kW 6.4
Fuse rating A 3 × 10
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (H07 RN-F without plug)
(supplied)
mm 2000
Installationsplan PT 7136 / PT 5136 EL
Stand: 15.11.2007 Seite 10
Plug and socket connection in accordance with IEC 60309
recommended to facilitate electrical safety tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Nominal air throughput in vented mode (at 60Hz) m³/h 300 (340) Vented
Permissible pressure attenuation (at 60Hz) Pa 320 (480)
Machine vent connection (d
ext
× s × l) [DN 100] mm 100 × 0.6 × 78
On-site vent connection (interior diameter) mm 100
Max. temperature °C 80
As relative humidity can be as high as 100%, suitable
measures must be taken to prevent a backflow of condensate
into the machine.
If the machine fan is unable to transport air over the on-site
vent ducting distance, an additional fan with a suitable
capacity must be installed either in the ducting or at the point
of discharge to atmosphere.
Standard connection:
Air intake from installation site
Air intake
Recommended air intake vent cross-section cm² 237
(to prevent draughts in installation site)
Sufficient air intake should be available to replace displaced
volume of air.
Miele plinth UG/UO 5005 Fittings (supplied)
4 × metal angled brackets (to secure machine to plinth)
4 × screws DIN 571 (Ø × length) mm 8 × 65
4 × rawl plugs (Ø × length) mm 12 × 60
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
On concrete platform
2 × screws DIN 571 (Ø × length) mm 6 × 50
2 × rawl plugs (Ø × length) mm 8 × 40
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
Without plinth
2 × screws DIN 571 (Ø × length) mm 6 × 50
2 × rawl plugs (Ø × length) mm 8 × 40
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
Payment system
Installationsplan PT 7136 / PT 5136 EL
Stand: 15.11.2007 Seite 11
The following extensions are possible:
Installation of payment system
Possible
extensions
Installation as washer-dryer stack
Connection to serial interface, RS 232
Machine data Width mm 595
Depth mm 700
Height mm 850
Knocked-down dimensions (W × H) mm 600 x 900
Recommended rear wall gap (measured to front of machine) mm 1100
Net weight kg 58
Dynamic floor load, max. N ~ 670
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
W 215
Acoustic power level (re1 pW) dB (A) 65
Sound pressure level
(measured at a distance of 1 m from the machine and at a
height of 1.6 m)
dB (A) approx. 52
Installation should only be carried out by authorised fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Measurements in mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11