Miele PT7135C Installation Plan

Type
Installation Plan

This manual is also suitable for

Installationsplan / Installation plan
Installatietekening
Plan d`installation
Piano di installazione
Plano de instalación
Plano de instalação
Σχέδιο εγκατάστασης
Asennusohje
Installasjonsplan
Installationsplan
G
PT 7135 C / PT 5135 C EL
Materialnummer / Mat. no.: 06 664 250
Änderungsstand / Version: 01
Datum Zeichnung / Drawing date: 25.04.2005
Datum Legende / Legend date: 31.05.2005
Installationsplan PT 7135 C / PT 5135 C EL
Stand: 31.05.2005 Seite 8
Technical datasheet
Tumble dryers:
Heating:
PT 7135 C / PT 5135 C
Electric (EL)
Legend:
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
G
Optional extras:
UG/UO 5005 Miele plinth
(UG = Box plinth/UO = Open plinth)
UM
Height Model mm 300
Width UG (UO) mm 609 (598)
Depth UG (UO) mm 622 (615)
Concrete platform Concrete platform optional (Min. quality B15)
Recommended height mm 300
BS
Minimum height mm 100
Recommended width mm 600
Recommended depth mm 650
Ensure good anchorage!
Machine connections:
1. Standard voltage (as supplied) V 2N AC 400
Frequency Hz 50
Rated load kW 3.68
Fuse rating A 2 × 10
Electrical
connection
D
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (H07 RN-F without plug)
(supplied)
mm 2000
1. Alternative voltage V 3 AC 230
Frequency Hz 50
Rated load kW 3.68
Fuse rating A 3 × 16
Supply lead as above
convertible
2. Alternative voltage V 1N AC 230
Frequency Hz 50
Rated load kW 3.68
Fuse rating A 1 × 16
Connection cable, min. cross-section mm² 3 × 1.5
Length of supply lead (H05 RN-F without plug)
(supplied)
convertible
mm 2000
3. Alternative voltage V 1N AC 230
Frequency Hz 50
Rated load kW 2.15
Fuse rating A 1 × 10
Supply lead as above
convertible
Country variations:
2. Standard voltage (as supplied) V 1N AC 220-230
Frequency Hz 50
G i
Rated load kW 2.7 – 2.95
Fuse rating A 1 × 13
Connection cable, min. cross-section mm² 3 × 1.5
Length of supply lead (H05 RN-F with plug)
(supplied)
mm 2000
Installationsplan PT 7135 C / PT 5135 C EL
Stand: 31.05.2005 Seite 9
3. Standard voltage (as supplied) V 2N AC 400
Frequency Hz 50
j S
Rated load kW 3.68
Fuse rating A 2 × 10
Connection cable, min. cross-section mm² 4 × 1.5
Length of supply lead (H05 RN-F without plug)
(supplied)
mm 2000
4. Standard voltage (as supplied) V 1N AC 230
Frequency Hz 50
N
Rated load kW 3.68
Fuse rating A 1 × 16
Connection cable, min. cross-section mm² 3 × 1.5
Length of supply lead (H05 RN-F without plug)
(supplied)
mm 2000
5. Standard voltage (as supplied) V 1N AC 230-240
Frequency Hz 50
W
Rated load kW 2.15 – 2.35
Fuse rating A 1 × 10
Connection cable, min. cross-section mm² 3 × 1.0
Length of supply lead (H05 RN-F with plug)
(supplied)
mm 2000
6. Standard voltage (as supplied) V 2N AC 200
Frequency Hz 50-60
J
Rated load kW 2.85
Fuse rating A 2 × 20
Connection cable, min. cross-section mm² 3 × 2.75
Length of supply lead (H05 RN-F with plug)
(supplied)
mm 2000
Plug and socket connection in accordance with IEC 60309
recommended to facilitate electrical safety tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Unobstructed vent required for cold air Cold air intake
Unobstructed vent required for cold air Cold air
discharge vent
Max. temperature °C 60
Drain hose (Int. dia. × wall thickness × l) [DN 10] mm 10 × 2.5 × 2000
Condensate drain
hose
Hose sleeve for drain hose to be provided on site (ext. dia. x l) mm 10 × 30
Max. transient throughput l/min 3
Max. head height (measured from base of unit) mm 1000
Miele plinth UG/UO 5005 Fittings (supplied)
4 × metal angled brackets (to secure machine to plinth)
4 × screws DIN 571 (Ø × length) mm 8 × 65
4 × rawl plugs (Ø × length) mm 12 × 60
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
On concrete platform
2 × screws DIN 571 (Ø × length) mm 6 × 50
2 × rawl plugs (Ø × length) mm 8 × 40
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
Installationsplan PT 7135 C / PT 5135 C EL
Stand: 31.05.2005 Seite 10
Without plinth
2 × screws DIN 571 (Ø × length) mm 6 × 50
2 × rawl plugs (Ø × length) mm 8 × 40
Machine must be bolted to the floor!
Fixing materials for floating screed floor to be provided on site
Payment system
The following extensions are possible:
Installation of payment system
Possible
extensions
Installation as washer-dryer stack
Connection to serial interface, RS 232
Machine data Width mm 595
Depth mm 700
Height mm 850
Knocked-down dimensions (W × H) mm 600 x 900
Recommended rear wall gap (measured to front of machine) mm 1100
Net weight kg 60
Dynamic floor load, max. N ~ 670
Average heat dissipation
(dependent on ambient room temperature and programme
selected)
W 2.500
Acoustic power level (re1 pW) dB (A) 68
Sound pressure level
(measured at a distance of 1 m from the machine and at a
height of 1.6 m)
dB (A) approx. 55
Installation should only be carried out by authorised fitters in accordance with valid regulations!
Observe installation instructions when installing machine! All rights reserved! Measurements in mm
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Miele PT7135C Installation Plan

Type
Installation Plan
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI