Installationsplan / Installation plan: PW 6241 EL
Datum / Date: 15.01.2007 Seite / Page: 8
Connection using multi-pole wall socket in compliance with
IEC 60309 and IEC 60947 is recommended in order to
simplify electrical tests.
Install mains isolator according to IEC 60947 on hard-wired
connection.
Wall socket or mains isolator must be accessible after
installation.
The use of an earth leakage circuit breaker (ELCB) is strongly
recommended. A type B RCD (residual current device) must
then be used.
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Connection cable, min. cross-section mm² 4 × 1.5
Peak-load
management Input leads (e.g. H05VV-F) should not be in direct contact with
any source of heat.
Input signal via potential-free (galvanically separated) contact.
Connection with male thread mm 10 × 35
with washers and nut. M 10
Equipotential
bonding
If necessary, equipotential bonding with good galvanic contact
must be provided in accordance with all appropriate national
and local regulations.
Min. flow pressure kPa 100
Max. pressure kPa 1000
Cold water
(Soft water)
Max. throughput (if hot and raw water supply is not available) l/min 35.5 [80]
On-site connection thread according to DIN 44 991 Inch 1" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme)
Standard connection (with hot water connection) l/h Approx. 61
Additional requirements if hot water supply is not available.
Additional requirements if raw water supply is not available.
Max. temperature °C 70
Min. flow pressure kPa 100
Hot water
Max. pressure kPa 1000
Max. throughput l/min 30
On-site connection thread according to DIN 44 991 Inch 1" external thread
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme) l/h Approx. 53
If no hot water supply, connect hose to cold water!
Min. flow pressure kPa 100
Max. pressure kPa 1000
Max. throughput l/min 40
On-site connection thread according to DIN 44 991 Inch 1" external thread
Cold water (hard
water)
Length of connection hose (parts supplied: 1 connection
hose)
mm 1500
Water requirements (average for 60°C programme) l/h Approx. 209
If no raw water supply, connect hose to cold water!
Max. temperature °C 95
Machine drain connection (da × s × l) [DN 70] mm 75 × 1.9 × 110
On-site drain connection (di × s × l) [DN 70 sleeve] mm 75 × 1.9 × 50
Drainage via
dump valve
Max. transient throughput l/min 200
Vented drainage required. If ventilation is insufficient, fit Miele
kit, Mat. no. 05238090.
Drain manifolds serving several machines must be of
sufficient cross-section.