2
10BTable of Contents
10B
Table of Contents .......................................................... 2
11B
Safety Information ......................................................... 2
0B
Warranty ......................................................................... 3
1B
Pre-Installation .............................................................. 4
13B
Planning For Successful Installation .......................... 4
14B
Installation Options ..................................................... 4
15B
Tools Required ........................................................... 5
Materials Required ..................................................... 5
16B
Hardware Included ..................................................... 5
3B17B
Package Contents ......................................................... 6
4B
Installation ..................................................................... 7
8B
Troubleshooting .......................................................... 11
9B
Care and Cleaning ...................................................... 12
12B
Specifications .............................................................. 12
18B
Dimensions .............................................................. 12
Service Parts ............................................................... 13
VFB25ACLED2 Serviceable Parts ........................... 13
11BSafet
Information
1. This ventilation fan is approved for use over a
bathtub or shower when installed in a GFCI
protected circuit. Do not use unapproved fans
over a bathtub or shower that is not approved for
that application.
2. Installation work must be carried out by a
qualified person(s) in accordance with all local
and safety codes including the rules for fire-rated
construction.
3. Always vent fans to the exterior and in
compliance with local codes.
4. Install ductwork in a straight line with minimal
bends.
5. Use 120 V, 60 Hz for the electrical supply and
properly ground the unit. Follow all local safety
and electrical codes.
6. Do not use this fan with any solid-state control
device; such as a dimmer switch. Solid-state
controls may cause harmonic distortion, which
can cause a motor humming noise.
7. Sufficient air is needed for proper combustion
and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
back drafting.
8. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
9. To reduce the risk of injury to persons, install fan
at least 8.2 ft. above the floor.
10. Not for use in cooking areas.
Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
conditioning Engineers (ASHRAE), and the local code
authorities.
45°
Cooking area
45°
Do not install above or
inside this area
Cooking
Equipment
Floor