infinitech DECORA 110 CFM Installation guide

Type
Installation guide
Page 1
WARNING CLEANING & MAINTENANCE
CAUTION
PREMIO SERIES
DECORA SERIES
READ AND SAVE THESE INSTRUCTIONS
www.InfiniTechInc.com
Applies to all 80 & 110 CFM
Installation Manual
Ventilation Fans
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS, PLEASE OBSERVE THE
FOLLOWING:
INSTPDF0508
Use this unit in the manner intended by the manufacturer. If
you have any questions, please contact the manufacturer.
Before servicing, cleaning, or maintaining the unit, switch
power off at service panel and lock the service
disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a warning device,
such as a tag, to the service panel.
Installation of unit and electrical wiring must be done in
accordance to all applicable codes and standards by a
licensed electrician.
When cutting or drilling into walls or ceilings, make sure not
to damage or cut electrical wiring, plumbing, or other
hidden utilities.
Always duct ventilation fans to the outdoor environment.
If UL approved for installs over showers or bathtubs, install
on a GFCI (Ground Fault Circuit Interrupter) protected
circuit.
This unit must be grounded.
The motor in this unit is permanently lubricated and will
never need oiling.
For proper operation and long life, remove grill and dust or
vacuum interior of unit every three months.
Do not use corrosive chemicals to clean plastic parts.
Make sure that power to the unit is off and locked out during
cleaning to avoid damage and injury.
InfiniTech warrants that this product will be defect free in
material and workmanship for a period of three years from the
date of original purchase. This warranty supersedes any and all
prior warranties, expressed, implied or written. During this
three year period, InfiniTech will, at its option, repair or replace,
without charge, any product or part which is found to be
defective under normal use and service.
THIS WARRANTY DOES NOT COVER THE FOLLOWING:
InfiniTech shall not be liable for incidental or consequential
damages, or special damages including, but not limited to, loss
of property, loss of revenues or profit, cost of removal, cost of
installation, or cost of reinstallation, personal damage or loss of
life arising out of or in connection with product use or
performance.
Damage caused by improper installation and improper
wiring or installation contrary to recommended
installation instructions provided by the manufacturer.
Products and parts that have been modified from their
original state.
Products that have been subject to improper repair,
improper maintenance, abuse, misuse, or accident.
OPERATION
WARRANTY
Use an on/off switch only to operate this ventilator.
Do not use this product with any solid state speed control
device.
Do not use to exhaust explosive materials, vapors, and
hazardous materials.
Do not mount product in wall. This unit is designed for
ceiling installations only.
Not intended for use in cooking areas.
To avoid damage and/or injury, keep foreign objects from
entering the fan during construction and operation.
1.
2.
3.
4.
5.
6.
7.
1.
2.
3.
4.
TM
Page 2
Installing the Unit
Figure 2
Figure 3
Figure 5
Figure 4
*Using the supplied hanger bars, the unit can be installed between all types of joist framings up to 16” with a minimum
height clearance of 9”.
INSTPDF0508
1. Remove Grill (Figure 1)
Remove the grill by pulling it away from the housing and gently
squeezing the wire springs to extract them from the slots within the
housing.
2. Mount Brackets
Slide the supplied mounting brackets into the appropriate slots
on the housing.
3. Position
Position the housing between the joists and extend the mounting
brackets until they come in contact with the joists. Make sure that the
bottom edge of the unit is flush with the ceiling.
4. Mark Location
Mark the screw locations on the joists through the holes in the
mounting brackets.
5. Remove
Remove the unit.
6. Mount Unit
Using the marked hole locations, drive screws part way
into the joists (Screws not supplied).
7. Secure Unit (Figure 2)
Mount the unit to the joists by positioning the unit in its location
using the screws in the joists. Once unit and mounting brackets are
lined up, secure by driving the screws tight.
8. Connect Duct (Figure 3)
Connect 4” duct to the unit by securely fastening it to the outlet.
Tape all connections to eliminate leaks.
* To increase efficiency and reduce noise, use the shortest possible duct length
with a minimum number of elbows.
* The unit needs to be vented to the outside environment. Do not vent into the attic.
* Use a roof jack or wall cap to terminate the duct run.
9. Electrical Connections (Figure 4)
Make all electrical connections as shown in the wiring diagram.
*Unit runs on 120 VAC only.
*Make sure to use all UL approved connectors to secure wiring to the wiring box.
10. Put Grill (Figure 5)
Attach grill to housing by gently squeezing wire springs and inserting
them into the slots on each side of the housing. Gently push grill
against the finished ceiling.
TM
Figure 1
Fa n
Connector
Red
White
Green
GND
M
C
C: Capacitor
M: Motor
~
Premio & Decora Fan (80 & 110 CFM)