Zenner WPD/WPHD/WPDE/WPHDE Operating instructions

  • Hello! I've reviewed the installation instructions for ZENNER water meters WPD, WPHD, WPDE and WPHDE. This document covers important details about the installation, intended use, and maintenance of the meters, including guidelines for replacing the metrological unit and ensuring correct operating conditions. I am ready to assist you with any questions you might have about these devices.
  • What is the maximum water temperature for the meter?
    What is the recommended straight inlet for the WP series?
    What is the flow sensitivity class?
    What should be checked when replacing the metrological unit?
1
Installationsanleitung
DieWPBaureihewurdemiteinerStrömungsempndlichkeitsklasse
U0/D0zugelassen.UmjedochdiebestenMessergebnissezuerreichen,
empfehlenwirdienationalenVorschrienundanerkanntenRegelnder
Technikzubeachten.
FürdieBaureiheWPwerdenalsgeradeEinlaufstreckemindestens3xDN
empfohlen.
IdealerweisesolltenalsAuslaufstreckemindestens2xDNvorhanden
sein.
VorderInstallationdesZählersistdieRohrleitungsorgfältigzuspülen.
DerRohrleitungsquerschnittsolltedirektvorundhinterdemZähler
nichtreduziertwerden.
FlanschdichtungendürfennichtindieRohrleitunghineinragen.
Esmussdaraufgeachtetwerden,dassdieDurchussrichtungdes
ZählersmitderDurchussrichtungderRohrleitungübereinstimmt.
VentileodersonstigeDurchussregulierungensolltenmöglichsthinter
demZählermontiertwerden.
DerZählersolltenichtanderhöchstenStellederRohrinstallation
installiertwerden,damitsichkeineLublasenimZählerbildenkönnen
unddieRohrleitungdadurchimmervollständiggefülltist.
DerZählersollteggf.durcheinenentsprechendenFiltergeschützt
werden,damitkeineFremdpartikel,wiez.B.SteineoderSand,indas
Messgerätgelangen.
DerZählermussvorDruckschlägenimRohrleitungsnetzgeschützt
werden.
DiemaximaleMedientemperaturdarfdiezulässigen50°CfürKaltwas-
sernichtüberschreiten.
UmBeschädigungendesMesseinsatzesdurchDruckschlägezuvermei-
den,mussdieRohrleitungnachderInstallationlangsamgefülltwerden.
Produktbeschreibung
GroßwasserzählerTypWPD/WPHDfürKaltwasserbis50°C.
GroßwasserzählerTypWPDE/WPHDE(Funkwasserzähler)mitwerksseitig
montiertemundkonguriertemEDC-FunkmodulfürKaltwasserbis50°C.
Verwendungszweck
ZurMessungvonTrinkwasserbis50°C
ZurMessungvonsauberemBrauchwasserbis50°C
Lieferumfang
1Wasserzähler,1Montageanleitung,Konformitätserklärung
Bemerkung
DieseMontageanleitungrichtetsichnuranqualiziertesFachpersonal.
GrundlegendeInstallationsschrittesinddahernichtbeschrieben.
BeidenNenngrößenDN150bisDN300istderabgeleseneZählerstandmit
Faktorx10zumultiplizieren,beidenNenngrößenDN400undDN500x100.
Zulässige Einbaulagen
DieBaureiheistfürdieEinbaulagenhorizontalundvertikalbestimmt.
Esistdafürzusorgen,dassderZählerspannungsfreiinderRohrleitung
eingebautwird.BeieinemnichtspannungsfreienEinbaukanndas
ZählergehäusebeschädigtwerdenundeskannWasserentweichen.
DerRohrleitungsdruckdarfdenzulässigenBetriebsdruckdesZählers
nichtüberschreiten,dadieszuUndichtigkeitenundBeschädigungen
desZählersführenkann.
UmdieDemontagedesZählerszuverhindern,empfehlenwir,die
AnschlussschnittstellemittelseinerBenutzersicherung(Klebemarke,
Verplombungo.ä.)zusichern.
AlleBaureihenwurdenmiteinerStrömungsempndlichkeitsklasseU0/
D0zugelassen(keineEin-/Auslaufstreckeerforderlich).
AlleBaureihensindfürdieMessungvonRückströmungnichtzugelas-
sen.
Installationsanleitung für den Wechsel der metrologischen Einheit
Messeinsatz)
DerWechselvonaustauschbaren,metrologischenEinheitensolltenur
vonqualiziertemFachpersonalvorgenommenwerden.
VordemWechseldermetrologischenEinheit,dieRohrleitungsorgfältig
spülen,druckseitigabsperrenundentleeren.
DierichtigeÜbereinstimmungderSchnittstellen-Kennzeichnungauf
dermetrologischenEinheitundaufdervorgesehenenSchnittstelleist
zuüberprüfen.SchnittstelleWP1fürDN40–150bzw.SchnittstelleWP5
fürDN200–300.
AlteDichtungen/DichtringesindunverglichnachEntfernendermet-
rologischenEinheitzuentfernen.DieentsprechendenDichtächensind
zureinigenundaufBeschädigungenzuüberprüfen.
Esistdaraufzuachten,dassderZulaufbereichfreivonAblagerungen
ist,dadiesezuAbweichungendesMessergebnissesführenkönnen,
bevoreineneuemetrologischeEinheiteingebautwird.
EssindausschließlichnurOriginal-Dichtungen,diezusammenmitder
metrologischenEinheitgeliefertwerden,zuverwenden.Diesesindvor
demEinbauaufBeschädigungenundPassgenauigkeitzuüberprüfen.
BeiderVerwendungvonSchmiermitteln/Montagepastenfürdie
Dichtungenmusssichergestelltsein,dassdiesefürdenKontaktmit
Trinkwassergeeignetsind.
DieBefestigungsschraubendermetrologischenEinheitüberKreuz
gleichmäßiganziehen(M12:DN40–DN125=60Nm;M16:DN150–DN300
=85Nm).
DieaustauschbaremetrologischeEinheitmussmitderAnschluss-
schnittstelle(Gehäuse)mittelseinerBenutzersicherung(Plomben-
draht)gegenDemontagedesMesseinsatzesgesichertwerden.
DieKonformitätserklärungistimLieferumfangenthalten.Diese,unddie
neuestenInformationenzumProduktkönnenauchunterwww.zenner.de
abgerufenwerden.
WPD/WPHD/WPDE/WPHDE
Deutsch
Montageanleitung
2
L
H1 H2
DN
H3
D1
D
Abmessungen und Gewichte WPD/WPDE
Nennweite DN mm 40 50 65 80 80 100 125 150
Betriebsdruck MAP bar 16 16 16 16 10 16 16 16
Baulänge 1L mm 300 200/270/
300 200 200/225/
300/350 225 250/350/
360 250 300
Höhe H1 mm 135 135 135 143 143 152 152 183
Höhe H2 mm 65 75 85 95 95 105 115 135
Gesamthöhe ca. 2H1+H2 mm 200 210 220 238 238 257 267 318
Ausbauhöhe Messeinsatz H3 mm 230 230 230 256 256 266 266 373
Durchmesser Flansch D mm 150 165 185 200 200 220 250 285
Durchmesser Lockreis D1 mm 110 125 145 160 160 180 210 240
Anzahl Schrauben -Stück 44484888
Schraubengröße -mm M16 M16 M16 M16 M16 M16 M16 M20
Durchmesser Schraubenloch -mm 19 19 19 19 19 19 19 23
Gewicht ca. -kg 8,8 9,1/10,7/
11,1 11,8 14,1/13,4/
15,9/16,8 13,4 16,9/13,8/
20,6 20,1 31,5
Fernübertragung
Impulswertigkeit Reed -l/Imp. 100 100 100 100 100 100 100 1000
Impulswertigkeit Modulatorscheibe -l/Imp. 10 10 10 10 10 10 10 100
1 AndereBaulängen(ISOBaulängen)aufAnfrage
2GesamthöheWPDE+24mm
FlanschenachISO7005-2.AndereFlanscheaufAnfrage
Abmessungen und Gewichte WPHD/WPHDE
Nennweite DN mm 200 200 250 250 300 300
Betriebsdruck MAP bar 16 10 16 10 16 10
Baulänge 1L mm 350 350 450 450 500 500
Höhe H1 mm 215 215 267 267 250 250
Höhe H2 mm 160 160 193 193 220 220
Gesamthöhe ca. 2H1+H2 mm 375 375 460 460 470 470
Ausbauhöhe Messeinsatz H3 mm 460 460 460 460 470 470
Durchmesser Flansch D mm 340 340 405 395 460 445
Durchmesser Lockreis D1 mm 295 295 355 350 410 400
Anzahl Schrauben -Stück 12 812 12 12 12
Schraubengröße -mm M20 M20 M24 M20 M24 M20
Durchmesser Schraubenloch -mm 23 23 28 23 28 23
Gewicht ca. -kg 49 49 68 68 105 105
Fernübertragung
Impulswertigkeit Reed -l/Imp. 1000 1000 1000 1000 1000 1000
Impulswertigkeit Modulatorscheibe -l/Imp. 100 100 100 100 100 100
1 AndereBaulängen(ISOBaulängen)aufAnfrage
2GesamthöheWPHDE+24mm
FlanschenachISO7005-2.AndereFlanscheaufAnfrage
ZENNER International GmbH & Co. KG
Heinrich-Barth-Stre29|66115Saarbcken|Germany
Telefon +4968199676-30
Telefax +4968199676-3100
E-Mail info@zenner.com
Internet www.zenner.com
TechnischeÄnderungenvorbehalten.FüretwaigeIrrtümerundDruckfehlerübernehmenwirkeineHaung.ZRI_SAP149974_220517_DE_EN
Abmessungen
3
Installation manual
TheWPserieshasbeenapprovedwithaowsensitivityclassU0/D0.
However,toachievethebestmeasurementresults,werecommend
observingnationalregulationsandrecognisedrulesoftechnology.
ForWPseriesisrecommendedastraightinletsectionofatleast3xDN.
Ideally,atleast2xDNshouldbeavailableastheoutletsection.
Beforeinstallingthemeter,thepipingmustbethoroughlyushedout.
Thepipediametershouldnotbereduced,directlyinfrontandbehind
themeter.
Flangegasketsmustnotextendintothepipe.
Itmustbeensuredthattheowdirectionofthemetermatchesthatof
thepipe.
Valvesorotherowregulatorsshouldbeinstalled,wherepossible,
behindthemeter.
Themetershouldnotbeinstalled,wherepossible,atthehighestpoint
ofthepipeinstallationsothatairbubblesarenotabletoforminthe
meterandthepipeisalwayscompletelylled.
Ifnecessary,themetershouldbeprotectedbyacorrespondinglter,
sothatnoforeignparticles,suchasstonesorsand,areushedintothe
measuringinstrumentandcausedamage.
Themetermustbeprotectedagainstpressuresurgesinthepipenet-
work.
Themaximumwatertemperaturemustnotexceedthepermissible50
°Cforcoldwater.
Inordertopreventdamagetothemeasuringinsertcausedbypressure
surges,thepipemustbeslowlylledfollowinginstallation.
Product description
BulkwatermetertypeWoltmanWPD/WPHDforcoldwaterupto50°C.
BulkwatermetertypeWPDE/WPHDE(radiowatermeter)withfactory
assembledandparameterizedEDCradiomoduleforcoldwaterupto50°C.
Intended use
Forthemeasuringofdrinkingwaterupto50°C
Forthemeasuringofcleanindustrialwaterupto50°C
Scope of delivery
1watermeter,1instructionmanual,DeclarationofConformity
Remark
Thisinstallationmanualisintendedforqualiedspecialistsonly.Basic
installationstepsarethereforenotdescribed.
Themeterreadingmustbemultipliedbyfactorx10,forthenominalsizes
DN150toDN300,thenominalsizesDN400andDN500byfactorx100.
Permissible installation positions
TheWPseriesisintendedforinstallationinthehorizontalandvertical
positions.
Itmustbeensuredthatthemeterisinstalledinade-energisedstate
inthepipe.Inthecaseofaninstallationthatisnotde-energised,the
housingofthemeasuringinstrumentcanbedamagedandwatermay
escape.
Thepipelinepressuremustnotexceedthemaximumworkingpressure
ofthemeter,asthiscanleadtoleaksanddamageofthemeter.
Topreventthedisassemblyofthemeterwerecommendtosecurethe
connectioninterfacewithasafetydevice(adhesivelabel,seal,etc.).
AllserieshasbeenapprovedwithaowsensitivityclassU0/D0(noinlet
outletsectionrequired).
Allseriesarenotapprovedforbackowmeasuring.
Installation instructions for the replacement of the metrological unit
Theexchangeofexchangeablemetrologicalunitsmeasuringinsert
shouldonlybeperformedbytrainedspecialiststa.
Beforechangingthemeasuringinsert,thepipemustberinsedcarefully
shutothepressuresideandemptythepipe.
Thecomplianceoftheinterfacesmarkingonthemeasuringandatthe
speciedinterface(body)mustbechecked.InterfaceWP1forDN40–
150andtheinterfaceWP5forDN200–300.
Aerdisassemblyofthemeasuringinsertoldgaskets/sealsmustbere-
moved.Thesealingsurfacesmustbecleanedandcheckedfordamage.
Itisimportanttoensurethattheinletareaisfreeofdeposit,beforea
newmetrologicalunitisinstalled,becauseasthesecanleadtodevia-
tionsofthemeasurementresult.
Useonlythegenuineseals,whicharedeliveredtogetherwiththe
measuringinsert.Thesehavetobecheckedpriortoinstallationfor
damageandt.
Whenusinglubricants/assemblypastese.g.fortheseals,itmustbe
ensuredthatthesearesuitableforcontactwithdrinkingwater.
Tightenthescrewsofthemeasuringunitevenlycrosswise(M12:DN40–
DN125=60Nm;M16:DN150–DN300=85Nm).
Topreventthedisassemblyofthereplacablemeasuringinsert,itmust
beconnectedwiththeconnectioninterface(housing)byasealingwire.
Thedeclarationofconformityisincludedinthedelivery.Thelatestinforma-
tiononthisproductcanbecalledupfromwww.zenner.com
WPD/WPHD/WPDE/WPHDE
English
Installation instructions
4
L
H1 H2
DN
H3
D1
D
Weight and dimensions WPD/WPDE
Nominal diameter DN mm 40 50 65 80 80 100 125 150
Operating pressure MAP bar 16 16 16 16 10 16 16 16
Overall length 1L mm 300 200/270/
300 200 200/225/
300/350 225 250/350/
360 250 300
Height H1 mm 135 135 135 143 143 152 152 183
Height H2 mm 65 75 85 95 95 105 115 135
Total height approx. 2H1+H2 mm 200 210 220 238 238 257 267 318
Installation height of the measuring unit H3 mm 230 230 230 256 256 266 266 373
Flange diameter D mm 150 165 185 200 200 220 250 285
Bolt circle diameter D1 mm 110 125 145 160 160 180 210 240
Number of bolts -pcs. 44484888
Screw size -mm M16 M16 M16 M16 M16 M16 M16 M20
Bolt diameter -mm 19 19 19 19 19 19 19 23
Weight approx. -kg 8.8 9.1/10.7/
11.1 11.8 14.1/13.4/
15.9/16.8 13.4 16.9/13.8/
20.6 20.1 31.5
Remote transmission
Pulse value Reed -l/pulse 100 100 100 100 100 100 100 1000
Pulse value of the modulator disc -l/pulse 10 10 10 10 10 10 10 100
1 Otherlenghtsonrequest
2TotalheightWPDE+24mm
FlangesaccordingtoISO7005-2.Otherangestandardsonrequest
Subjecttotechnicalmodications.Weacceptnoliabilityforanyerrorsormisprints.
Weight and dimensions WPHD/WPHDE
Nominal diameter DN mm 200 200 250 250 300 300
Operating pressure MAP bar 16 10 16 10 16 10
Overall length 1L mm 350 350 450 450 500 500
Height H1 mm 215 215 267 267 250 250
Height H2 mm 160 160 193 193 220 220
Total height approx. 2H1+H2 mm 375 375 460 460 470 470
Installation height of the measuring unit H3 mm 460 460 460 460 470 470
Flange diameter D mm 340 340 405 395 460 445
Bolt circle diameter D1 mm 295 295 355 350 410 400
Number of bolts -pcs. 12 812 12 12 12
Screw size -mm M20 M20 M24 M20 M24 M20
Bolt diameter -mm 23 23 28 23 28 23
Weight approx. -kg 49 49 68 68 105 105
Remote transmission
Pulse value Reed -l/pulse 1000 1000 1000 1000 1000 1000
Pulse value of the modulator disc -l/pulse 100 100 100 100 100 100
1 Otherlenghtsonrequest
2TotalheightWPHDE+24mm
FlangesaccordingtoISO7005-2.Otherangestandardsonrequest
ZENNER International GmbH & Co. KG
Heinrich-Barth-Stre29|66115Saarbcken|Germany
Phone +4968199676-30
Fax +4968199676-3100
E-Mail info@zenner.com
Internet www.zenner.com Dimensions
/