Zenner WSD/WSDE Installation guide

  • Hello! I'm your chat assistant, and I've reviewed the installation instructions for the ZENNER WS series water meters, specifically the WSD and WSDE models. This document provides important details on horizontal installation, flow direction, and temperature limitations. I'm ready to answer your questions about these devices and their proper installation process.
  • What is the recommended installation position for the WS series?
    What is the recommended straight inlet section for the WS series?
    What is the maximum permissible water temperature for the meter?
    Is the WS series approved for backflow measuring?
WSD/WSDE
Deutsch
Montageanleitung
Installationsanleitung
DieWSBaureihewurdemiteinerStrömungsempndlichkeitsklasse
U0/D0zugelassen.UmjedochdiebestenMessergebnissezuerreichen,
empfehlenwirdienationalenVorschrienundanerkanntenRegelnder
Technikzubeachten.
FürdieBaureiheWSwerdenalsgeradeEinlaufstreckemindestens5xDN
empfohlen.
IdealerweisesolltenalsAuslaufstreckemindestens2xDNvorhanden
sein.
VorderInstallationdesZählersistdieRohrleitungsorgfältigzuspülen.
DerRohrleitungsquerschnittsolltedirektvorundhinterdemZähler
nichtreduziertwerden.
FlanschdichtungendürfennichtindieRohrleitunghineinragen.
Esmussdaraufgeachtetwerden,dassdieDurchussrichtungdesZäh-
lersmitderDurchussrichtungderRohrleitungübereinstimmt.
VentileodersonstigeDurchussregulierungensolltenmöglichsthinter
dem Zähler montiert werden.
DerZählersolltenichtanderhöchstenStellederRohrinstallation
installiertwerden,damitsichkeineLublasenimZählerbildenkönnen
unddieRohrleitungdadurchimmervollständiggefülltist.
DerZählersollteggf.durcheinenentsprechendenFiltergeschützt
werden,damitkeineFremdpartikelwiez.B.SteineoderSandindas
Messgerätgelangen.
DerZählermussvorDruckschlägenimRohrleitungsnetzgeschützt
werden.
DiemaximaleMedientemperaturdarfdiezulässigen50°CfürKaltwas-
sernichtüberschreiten.
UmBeschädigungendesMesseinsatzesdurchDruckschlägezuvermei-
den,mussdieRohrleitungnachderInstallationlangsamgefülltwerden.
Esistdafürzusorgen,dassderZählerspannungsfreiinderRohrleitung
eingebautwird.BeieinemnichtspannungsfreienEinbaukanndasZäh-
lergehäusebeschädigtwerdenundeskannWasserentweichen.
DerRohrleitungsdruckdarfdenzulässigenBetriebsdruckdesZählers
nichtüberschreiten,dadieszuUndichtigkeitenundBeschädigungen
desZählersführenkann.
UmdieDemontagedesZählerszuverhindern,empfehlenwir,die
AnschlussschnittstellemittelseinerBenutzersicherung(Klebemarke,
Verplombungo.ä.)zusichern.
AlleBaureihenwurdenmiteinerStrömungsempndlichkeitsklasseU0/
D0zugelassen(keineEin-/Auslaufstreckeerforderlich).
AlleBaureihensindfürdieMessungvonRückströmungnichtzugelas-
sen.
InstallationsanleitungfürdenWechseldermetrologischenEinheit
(Messeinsatz)
DerWechselvonaustauschbaren,metrologischenEinheitensolltenur
vonqualiziertemFachpersonalvorgenommenwerden.
VordemWechseldermetrologischenEinheit,dieRohrleitungsorgltig
spülen,druckseitigabsperrenundentleeren.
DierichtigeÜbereinstimmungderSchnittstellen-Kennzeichnungauf
dermetrologischenEinheitundaufdervorgesehenenSchnittstelle
(WS1)istzuüberprüfen.
AlteDichtungen/DichtringesindunverzüglichnachEntfernendermet-
rologischenEinheitzuentfernen.DieentsprechendenDichtächensind
zureinigenundaufBeschädigungenzuüberprüfen.
Esistdaraufzuachten,dassderZulaufbereichfreivonAblagerungen
ist,dadiesezuAbweichungendesMessergebnissesführenkönnen,
bevoreineneuemetrologischeEinheiteingebautwird.
EssindausschließlichnurOriginal-Dichtungen,diezusammenmitder
metrologischenEinheitgeliefertwerden,zuverwenden.Diesesindvor
demEinbauaufBeschädigungenundPassgenauigkeitzuüberprüfen.
BeiderVerwendungvonSchmiermitteln/Montagepastenfürdie
Dichtungenmusssichergestelltsein,dassdiesefürdenKontaktmit
Trinkwassergeeignetsind.
DieBefestigungsschraubendermetrologischenEinheitüberKreuz
gleichmäßiganziehen(M12:DN50–DN100=60Nm;M20:DN150–DN200
=100Nm).
DieaustauschbaremetrologischeEinheitmussmitderAnschluss-
schnittstelle(Gehäuse)mittelseinerBenutzersicherung(Plomben-
draht)gegenDemontagedesMesseinsatzesgesichertwerden.
DieKonformitätserklärungistimLieferumfangenthalten.Diese,unddie
neuestenInformationenzumProduktkönnenauchunterwww.zenner.de
abgerufenwerden.
Bemerkung
DieseMontageanleitungrichtetsichnuranqualiziertesFachpersonal.
GrundlegendeInstallationsschrittesinddahernichtbeschrieben.
ZulässigeEinbaulagen
DieBaureiheWSistnurfürdiehorizontaleEinbaulagebestimmt.
2
TechnischeÄnderungenvorbehalten.FüretwaigeIrrtümerundDruckfehlerübernehmenwirkeineHaung.ZRI_SAP147526_220518_DE_EN
Technische Daten
Nennweite DN mm 50 65 80 80 100 150 200
Betriebsdruck MAP bar 16 16 16 10 16 16 16
Baulänge 1 L mm 200/270/300 300 225/300/350 300 250/350/360 500 500
Höhe H1 mm 143 143 190 190 195 270 351
Höhe H2 mm 85 95 102 102 114 146 174
Gesamthöhe ca. 2 H1+H2 mm 228 238 292 292 309 416 525
Ausbauhöhe Messeinsatz H3 mm 270 270 370 370 382 557 743
Durchmesser Flansch D mm 165 185 200 200 220 285 340
Durchmesser Lockreis D1 mm 125 145 160 160 180 240 295
Anzahl Schrauben -Stück 4 4 8 4 8 8 12
Schraubengröße - mm M16 M16 M16 M16 M16 M20 M20
Schraubenloch Durchmesser - mm 19 19 19 19 19 23 23
Gewicht ca. kg 11/13/13 18 19/21/22 21 20/24/24 58 94
Fernübertragung
Impulswertigkeit Reed - l/Imp. 100 100 100 100 100 1000 1000
Impulswertigkeit Modulatorscheibe - l/Imp. 10 10 10 10 10 100 100
1AndereBaulängen(WP/ISOBaulängen)aufAnfrage
2GesamthöheWSDE+20mm
FlanschenachISO7005-2.AndereFlanscheaufAnfrage
Achtung:NichtalleAushrungensindinallenMärktenerhältlich
Abmessungen
ZENNER ZENNER
3
M 18 0102
DN 50 -125
(WSD DN 50 - 200)
DN 150 - 300
D
H2 H1
L
DN
H3
D1
Sicherungsstelle
Safety device
Kennzeichnung
Anschlussschnittstelle
Marking connection interface
Benutzersicherung
für Reedschalter
User safety for Reed switch
ZENNER International GmbH & Co. KG
Heinrich-Barth-Straße29|66115Saarbrücken|Germany
Phone +4968199676-30
Fax +4968199676-3100
E-Mail info@zenner.com
Internet www.zenner.com
English
Installation manual
TheWSserieshasbeenapprovedwithaowsensitivityclassU0/D0.
However,toachievethebestmeasurementresults,werecommend
observingnationalregulationsandrecognisedrulesoftechnology.
ForWSseriesisrecommendedastraightinletsectionofatleast5xDN.
Ideally,atleast2xDNshouldbeavailableastheoutletsection.
Beforeinstallingthemeter,thepipingmustbethoroughlyushedout.
Thepipediametershouldnotbereduced,directlyinfrontandbehind
the meter.
Flangegasketsmustnotextendintothepipe.
Itmustbeensuredthattheowdirectionofthemetermatchesthatof
the pipe.
Valvesorotherowregulatorsshouldbeinstalled,wherepossible,
behindthemeter.
Themetershouldnotbeinstalled,wherepossible,atthehighestpoint
ofthepipeinstallationsothatairbubblesarenotabletoforminthe
meterandthepipeisalwayscompletelylled.
Ifnecessary,themetershouldbeprotectedbyacorrespondinglter,
sothatnoforeignparticles,suchasstonesorsand,areushedintothe
measuringinstrumentandcausedamage.
Themetermustbeprotectedagainstpressuresurgesinthepipe
network.
Themaximumwatertemperaturemustnotexceedthepermissible50
°Cforcoldwater.
Inordertopreventdamagetothemeasuringinsertcausedbypressure
surges,thepipemustbeslowlylledfollowinginstallation.
Itmustbeensuredthatthemeterisinstalledinade-energisedstate
inthepipe.Inthecaseofaninstallationthatisnotde-energised,the
housingofthemeasuringinstrumentcanbedamagedandwatermay
escape.
Thepipelinepressuremustnotexceedthemaximumworkingpressure
ofthemeter,asthiscanleadtoleaksanddamageofthemeter.
Topreventthedisassemblyofthemeterwerecommendtosecurethe
connectioninterfacewithasafetydevice(adhesivelabel,seal,etc.).
AllserieshasbeenapprovedwithaowsensitivityclassU0/D0(noinlet
outletsectionrequired).
Allseriesarenotapprovedforbackowmeasuring.
Installation instructions for the replacement of the metrological unit
Theexchangeofexchangeablemetrologicalunits(measuringinsert
shouldonlybeperformedbytrainedspecialiststa.
Beforechangingthemeasuringinsert,thepipemustberinsedcarefully
shutothepressuresideandemptythepipe.
Thecomplianceoftheinterfacesmarkingonthemeasuringandatthe
speciedinterface(body)(WS1)mustbechecked.
Aerdisassemblyofthemeasuringinsertoldgaskets/sealsmustbere-
moved.Thesealingsurfacesmustbecleanedandcheckedfordamage.
Itisimportanttoensurethattheinletareaisfreeofdeposit,beforea
newmetrologicalunitisinstalled,becauseasthesecanleadtodevia-
tions of the measurement result.
Useonlythegenuineseals,whicharedeliveredtogetherwiththe
measuringinsert.Thesehavetobecheckedpriortoinstallationfor
damageandt.
Whenusinglubricants/assemblypastese.g.fortheseals,itmustbe
ensuredthatthesearesuitableforcontactwithdrinkingwater.
Tightenthescrewsofthemeasuringunitevenlycrosswise(M12:DN50–
DN100=60Nm;M20:DN150–DN200=100Nm).
Topreventthedisassemblyofthereplacablemeasuringinsert,itmust
beconnectedwiththeconnectioninterface(housing)byasealingwire.
Thedeclarationofconformityisincludedinthedelivery.Thelatestinforma-
tiononthisproductcanbecalledupfromwww.zenner.com
Remark
Thisinstallationmanualisintendedforqualiedspecialistsonly.Basic
installationstepsarethereforenotdescribed.
Permissible installation positions
TheWSseriesisintendedforinstallationinthehorizontalpositiononly.
Installation instructions
WSD/WSDE
4
Subjecttotechnicalmodications.Weacceptnoliabilityforanyerrorsormisprints.
Technical Data
Nominal Diameter DN mm 50 65 80 80 100 150 200
Operating pressure MAP bar 16 16 16 10 16 16 16
Overall length 1L mm 200/270/300 300 225/300/350 300 250/350/360 500 500
Height H1 mm 143 143 190 190 195 270 351
Height H2 mm 85 95 102 102 114 146 174
Total height approx. 2H1+H2 mm 228 238 292 292 309 416 525
Removal height measuring unit H3 mm 270 270 370 370 382 557 743
Flange diameter D mm 165 185 200 200 220 285 340
Bolt circle diameter D1 mm 125 145 160 160 180 240 295
Number of bolts -Pcs. 4 4 8 4 8 8 12
Screw size - mm M16 M16 M16 M16 M16 M20 M20
Bolt diameter - mm 19 19 19 19 19 23 23
Weight approx. kg 11/13/13 18 19/21/22 21 20/24/24 58 94
Remote transmission
Pulse value Reed - l/pulse 100 100 100 100 100 1000 1000
Pulse value modulator disc - l/pulse 10 10 10 10 10 100 100
1Otherlenghts(WP/ISOlenghts)onrequest
2TotalheightWSDE+20mm
FlangesaccordingtoISO7005-2.Otherangestandardsonrequest
Attention:Notallversionsareavailableinallmarkets
Dimensions
ZENNER ZENNER
3
M 18 0102
DN 50 -125
(WSD DN 50 - 200)
DN 150 - 300
D
H2 H1
L
DN
H3
D1
Sicherungsstelle
Safety device
Kennzeichnung
Anschlussschnittstelle
Marking connection interface
Benutzersicherung
für Reedschalter
User safety for Reed switch
ZENNER International GmbH & Co. KG
Heinrich-Barth-Straße29|66115Saarbrücken|Germany
Phone +4968199676-30
Fax +4968199676-3100
E-Mail info@zenner.com
Internet www.zenner.com
/