  • Hello! I am an AI chatbot trained to assist you with the WURM X-tra-1 Product information. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Expansion module for FRIGOENTRY BLUELINE
X-tra-1_Vx.x_PI_2017-12_EN.fm 1
Subject to technical changes
X-tra-1
1 Front view
Fig. 1: Front view
2 Features
Control and supply via data interface to FRIGOENTRY BLUELINE series devices
2 inputs for temperature sensor and 1 input for pressure transmitter
2 solid-state relay outputs
Expansion module for FRIGOENTRY BLUELINE
2X-tra-1_Vx.x_PI_2017-12_EN.fm
Subject to technical changes
X-tra-1
3 Safety instructions
Writing conventions
Warning!
WARNING!
Avoid the described hazard: otherwise, electric voltage poses a hazard that could lead to death
or serious bodily injury.
Caution!
CAUTION!
Avoid the described hazard: otherwise minor or medium bodily injury or damage to property will
result.
For your safety
For safe operation and to avoid personal injury and equipment damage through operator error, always
read these instructions, become familiar with the device, and follow all safety instructions on the prod-
uct and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device
if the product is sold.
Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in case of improper use or use for
other than the intended purpose.
Warning!
WARNING! DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
Switch off the power to the entire plant when carrying out installation, wiring or removal work.
Otherwise a mains voltage and/or external voltage may still be present even if the control voltage
is switched off.
Only qualified electricians are permitted to wire the device.
Use only the correct tools for all work.
Take note of the maximum loads on all connections.
Check all wiring after connection.
Never expose the device to moisture, for example due to condensation or cleaning agents.
Take the device out of operation if it is faulty or damaged and is therefore compromising safe
operation.
Do not open the device.
Do not repair the device yourself. If the device requires repairs, send it in with an exact descrip-
tion of the fault.
Caution!
CAUTION! ELECTROMAGNETIC INTERFERENCE CAN CAUSE FAULTS!
Always use shielded data cables and place them far away from power lines.
Target group This manual is intended for "service technician" personnel.
Intended use X-tra-1 is an expansion module for FRIGOENTRY BLUELINE series
devices.
Expansion module for FRIGOENTRY BLUELINE
X-tra-1_Vx.x_PI_2017-12_EN.fm 3
Subject to technical changes
X-tra-1
Validity of the documentation
Any software versions not listed are special solutions for individual projects and are not described in detail in this
document. This document automatically ceases to be valid if a new technical description is issued.
Manufacturer: Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid
You can find more information on our website at www.wurm.de.
4 Connection diagram
Fig. 2: Connection diagram
Date Functional upgrade
2017-12 Documentation status
Pos. Designation Function
1Solid-state relay outputs SSR1...SSR2 Digital outputs
2Data interface Control and power supply via FRIGOEN-
TRY BL devices
3Sensor inputs S1...S2 Temperature sensor
4Transmitter input p0Pressure transmitter
26
27
28
29
12 13 14 15 16 17 18
11
X-tra-1
Frigoentry Blueline
19
12
3
4
L‘
L
L‘
L
S1
S2
p
0
E
GND
U+
FRIGOENTRY BL
SSR1
SSR2
GND
GND
Expansion module for FRIGOENTRY BLUELINE
4X-tra-1_Vx.x_PI_2017-12_EN.fm
Subject to technical changes
X-tra-1
5 Installing the device
This device is designed for top-hat rail installation. The housing has standard dimensions according
to DIN 43880 and is also suitable for operation in fuse boxes and distribution cabinets.
The devices can be positioned immediately adjacent to one another without gaps.
Warning!
WARNING! DANGER TO LIFE FROM ELECTRIC SHOCK AND/OR FIRE!
Switch off the power to the entire plant before installing. Otherwise, a mains voltage and/or exter-
nal voltage may still be present even if the control voltage is switched off.
The entire system must be free of voltage.
1. (A) Place the module with the leading edge at an acute angle to the top-hat rail.
2. (B) Push the module down onto the top-hat rail.
The module snaps into place with the fastening safety catch (a) on the top-hat rail.
Fig. 3: Top-hat rail installation
6 Technical data
Power supply Via FRIGOENTRY BLUELINE devices
Pressure transmitter 4...20mA
Temperature sensor 2 x TRK-EEV
Solid-state relay output 2 x 230V~, 4...60VA, note the minimum output!
Residual voltage is measurable! Integrated semiconductor pro-
tection (no isolator).
Communication Ribbon cable for connection to FRIGOENTRY BLUELINE
devices
Dimensions (WxHxD) 53 x 90 x 58mm (DIN 43880)
Fastening Top-hat rail TH 35-15 or TH 35-7.5 (DIN EN 60715)
Ambient temperature Operation: 0...+55°C, storage: -25...+70°C
Weight About. 110g
CE conformity EU conformity as defined in
- 2014/30/EU (EMC Directive)
- 2014/35/EU (Low Voltage Directive)
RoHS II
A