  • Hello! I am an AI chatbot trained to assist you with the Aiphone TW Beacon-Strobe Install Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Tower Strobe
Strobe / Illumination Light Wiring Instructions
The following instructions are for wiring the beacon /strobe light on top of TW-Series towers, as well
as wiring the panel light located above the station mounting hole.
These instructions apply to models: TW-LCB, TW-LCK, TW-LCR, TW-LCW, and TW-LCY.
Locate the beacon/strobe wires and connect to a 24V DC power supply.
Red to +24V DC
Black to - (Ground)
Connect the white trigger wire to one side of a Normally Open (NO) relay on the emergency sub
station. Connect the other side of the Normally Open (NO) relay to the positive of the 24V DC
power supply.
Locate the panel light wires and connect to a 24V DC power supply.
Red to +24V DC
Black to - (Ground)
+
-
24VDC
Panel Light
Strobe
Refer to the sub station installation manual for its
complete wiring and dip switch setting options.
Pg. 1
Relay board on back
of IX-RA sub stations
Pg. 2
Tower Strobe Instr.
0118
Aiphone Corporation
www.aiphone.com
800-692-0200
SPECIFICATIONS:
Beacon / Strobe:
Voltage: 24V DC
Current: 300 mA
144 mA @ 24VDC in steady state mode
272mA@24VDCinashingmode
Light source: LED
Luminous output: 247 lm
Wiring: Black: Ground
Red: +24V DC
White: Trigger (+24V DC)
Wiring Distance: 18awg, 980’
Operating temp: -40°F to 149°F
Panel light:
Voltage: 24V DC
Current: 24 mA
Light source: LED
Luminous output: 100 lm
Wiring: Black: Ground
Red: +24V DC
Wiring Distance: 18awg, 980’
Operating temp: -40°F to 149°F
6-½"
7-¼"
/