Barco service bulletin
Important note : Locked projector hav e been reported i.e. LED 1 and LED
3 are lit up and projector does not start up.
This software (V1.12) will prevent this p roblem.
Upgrade o peratio n with the Co ntrol and Diagnostics client
Thefiletobesenttotheprojectorisafilewithextension.cab.
This file will be sent to the server and then internally via FTP to the PMP of the projector.
Some parts of the software (powerbox software,...) will only be installed once the in te rnal
FTP transfer has finished.
During this time the boot LED (LED3) will show an active status (led flickering).
LED 1
LED 2
LED 3
Image 1-1
Image 1-2
1.2 Upgrade from V1.00 or V1.02 to V1.12
1.2.1 Upgrade from V1.00 or V1.02 to V1.1 2
How to upgrade the firmware (from V1.00 or V1.0 2) ?
Theprojectormaybeintheoperationalstatus
1.Start the Control and Diagnostics client
2.Click on Configuration in the tool bar.
3.Click on Upgrade to open the firmware upgrade screen .
See image 1-3.
4.Use the Browse key to select the desired cab file.
5.Press the Upgrade buttononthebrowsertoselectthefile.
6.Press the Upgrade button on the upgrade screen to start the operation.
The information scre en will show the progress of the operation. (image 1-4)
7.When th e t ransfer is complete Done is shown. All the LED’s on the projector should be
off. (image 1-5)
8.After the Done m
essage has appeared, put the projector in standby, via the Control and
Diagnostics Client or the local keypad.
The Control and Diagnostics client will display a message that the projector has been
disconnected.
The Boot LED will blink for about 2 minutes (Green) during the cool down cycle. Do not
turn the Powe
r off during this period !
9.Switch off the iCon (power switch).
InfoT:
InfoT 628