Broan FT4BF-KA/B Product information

Type
Product information

This manual is also suitable for

AMB
HPS
W2 OUT
LPS
Y
OUT
Y2
OUT
Y2
W2 IN
L
COIL
C
Y
O
R
DF1 DF2
RV
BLACK
RED
OUTDOOR
FAN MOTOR
Y2
Y
L
R
C
DC SOL
COMFORT
ALERT MODULE
T1 T2
L1 L2
COMPRESSOR
HPS
LPS
RV COIL
CCH
BLACK
RED
BLUE
ORANGE
H
F
C
R
S
TO THERMOSTAT
AMB SENSOR
OD SENSOR
CONTACTOR
DEFROST BOARD
LFT
RT
S
L
H
C
ROUTE THIS WIRE
THROUGH THE “R”
OPENING IN COMFORT
ALERT MODULE
ROUTE THIS WIRE
THROUGH THE “C”
OPENING IN
COMFORT ALERT
MODULE
ROUTE THIS WIRE THROUGH
THE “S” OPENING IN COMFORT
ALERT MODULE
NC
NO
COM
GRND
GROUNDING
SCREW
FAN RELAY
CAPACITOR
L1 L2
YELLOW
RED
BROWN
CC- Contactor Coil
CCH - Crankcase Heater
CSC - Compressor Solenoid Coil
LPS - Low Pressure Switch
HPS - High Pressure Switch
RVS - Reversing Valve Solenoid
OFR - Outdoor Fan Relay
FRC - Fan Relay Coil
HPS
W2 OUT
LPS
Y
OUT
Y2
OUT
Y2
W2
IN
L
COIL
C
Y
O
R
AMBDF1 DF2
RV
DEFROST BOARD
S
L
H
R
H
F
C
Y2
Y
LR
C
DC
SOL
RV COIL
LPS
HPS
WIRING DIAGRAM
7109640
0809
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
YELLOW
BLACK
YELLOW
RED
BLACK
BLUE
BLACK
BLACK
BLACK
BLUE
YELLOW
R
S
C
OFR
CCH
L2
L1
T2
T1
OUTDOOR
FAN MOTOR
COMPRESSOR
CAPACITOR
COMFORT ALERT
CC
FRC
Y
R
O
C
Y2
L
CSC
AMB
SENSOR
COIL
SENSOR
208/230V
208/230V
Two Stage Split System Heat Pump With Demand Defrost and Two Speed Fan Motor Single Phase / 60 Hz.
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
3. Not suitable on systems that exceed 150 volts to ground.
4. For replacement wires use conductors suitable for 105
5. For ampacities and overcurrent protection, see unit rating plate.
6. Connect to 24 vac/40va/class 2 circuit. See furnace/airhandler installation
instructions for control circuit and optional relay/transformer kits.
1. Couper le courant avant
de faire letretien.
2. Employez uniquement des
conducteurs en cuivre.
3. Ne convient pas aux installations
de plus de 150 volt a la terre.
°C
Module has power
Status LED
Green “POWER”
Yellow “ALERT” Flash Code 1
Red “TRIP”
Yellow “ALERT” Flash Code 2
Yellow “ALERT” Flash Code 3
Thermostat demand signal Y is present,but the compressor is not running
Yellow “ALERT” Flash Code 4
Yellow “ALERT” Flash Code 5
Yellow “ALERT” Flash Code 6
Yellow “ALERT” Flash Code 7
Yellow “ALERT” Flash Code 8
Status LED Description
LONG RUN TIME - Compressor is running extremely long run cycle
SYSTEM PRESSURE TRIP - Discharge or suction pressure out of limits
or compressor overloaded
SHORT CYCLING - Compressor is running only briefly
LOCKED ROTOR
OPEN CIRCUIT
OPEN START CIRCUIT - Current only in run circuit
WELDED CONTACTOR - Compressor always runs
Yellow “ALERT” Flash Code 9
OPEN RUN CIRCUIT - Current only in start circuit
LOW VOLTAGE - Control circuit < 17 VAC
YELLOW
ORANGE
BLACK
WHITE
BLUE
BROWN
W1
¢7109648¤
  • Page 1 1

Broan FT4BF-KA/B Product information

Type
Product information
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI