DELTA DORE CV wind sensor can be best used when the user wants to automate control of outdoor blinds based on the wind speed and sunshine. The device can be associated with multiple receivers. This allows the user to control blinds in different locations or even control multiple blinds in one location. The device has a wind speed threshold setting that can be adjusted to protect the blinds from damage in high winds. The wind sensor also has a built-in sun sensor, which can be used to control the blinds based on the amount of sunlight. The DELTA DORE CV wind sensor is easy to install and use.

DELTA DORE CV wind sensor can be best used when the user wants to automate control of outdoor blinds based on the wind speed and sunshine. The device can be associated with multiple receivers. This allows the user to control blinds in different locations or even control multiple blinds in one location. The device has a wind speed threshold setting that can be adjusted to protect the blinds from damage in high winds. The wind sensor also has a built-in sun sensor, which can be used to control the blinds based on the amount of sunlight. The DELTA DORE CV wind sensor is easy to install and use.

Wind Sensor
Installation instructions
The wind sensor is designed to control
outdoor blinds automatically according
to wind speed and sunshine.
This sensor is associated via wireless
with one or more receivers controlling
the different shutters in your installation.
1. Comment fonctionne votre capteur ?
2. Description
1.1 Presentation
Wind
sensor
Protective
covers
Display
Programming
keypad
Removal
Not
used
Set wind
threshold
Association
Wind
Configuration
Wireless
transmission
signal
The sensor must be activated before
being used for the first time.
To do this, press and hold the
and
buttons for 2 seconds.
The display screen will turn on.
> 2s
The wind sensor switches
automatically into energy
saving mode after 30 seconds of
inaction.
Before each use, «activate» the
sensor by pressing any button.
3. Activation
4. Association
1 2
> 2s > 2s
ON
230V~
50 Hz
> 3s
TYXIA 4731
- Set the receiver(s) to
association wait mode.
- Press and hold the
button for 2
seconds.
- The symbols
and are displayed
while the device searches for receivers.
- The detected receiver number is dis-
played on the screen,
and the symbol «NEW» appears.
- Press and hold the
button to confirm
the association.
- On the receiver(s) check that the association
was successful. The receiver LED stops flashing
and the shutter briefly operates twice.
Display when the
sensor has detec-
ted more than 9
receivers.
Display when the sensor
has not detected any
receivers > Switches to
«Manage networks» mode
(see §10)
4
OK
OFF
Lithium battery - AA
cannot be replaced
Lithium battery life: 10 years
868 MHz (EN 300 220) - 100 m
IP
IPx4
-10°C / +70°C
-10°C / +60°C
260 x 104 x 130 mm
R&TTE 1999/5/CE
www.deltadore.com
5. Set wind threshold
> 2s
10 km/h
threshold
Slight breeze
20 km/h
threshold
Gentle breeze
30 km/h
threshold
Moderate breeze
(default value)
40 km/h
threshold
Fresh breeze
50 km/h
threshold
Strong wind
66 km/h
threshold
Very strong wind
To protect the shutter or blind equipment, select the wind threshold
recommended by the manufacturer.
- Press and hold the
button for 2 seconds.
- The
symbol will flash.
- Press and hold the
button to select the next
value.
For safety reasons, the wind
sensor cannot be neutralised.
The mode is exited
automatically after
5 seconds of inaction.
6. Use example for TYXIA 4731
Remote control
TYXIA 1605
P/N: 6351391
Receiver
TYXIA 4731
P/N: 6351390
230V~
2 VA
N L
230V~
2A /450W
LN N
1
2
1
2
3
For the warranty and protection of your shutters,
the wind sensor is recommended for installations
which include Motorised Blackout Blinds.
Associated products:
TYXIA 630 pack P/N: 6351392
8. Display of Wind Sensor setting
7. Test
The mode is exited automatically after 5 seconds of inaction.
> 2s
> 2s
To test that the sensors are operating correctly.
- The sensor simulate the setting threshold and sends the required
command to the receiver.
- Press and hold the
button for 2 seconds
then the button.
You can view the saved setting
1
4
2
3
- Remove the 2
protective
covers
- Replace
the protective
covers
- Straighten the
sensor
by positioning
the cups
horizontally
- Attach the sen-
sor (screws and
plugs included)
Cups
9. Installation
To remove a receiver associated with
the sensor, follow these instructions:
> 2s
1
1
2
> 2s
> 2s
- Press and hold the
button for
2 seconds.
- Press and hold the
button for 2 seconds.
- The receiver number flashes for 2 seconds.
- The sensor display switches off, and the
association between
receiver 1 and the sensor is now removed.
«Manage networks» mode
- The device runs a search for associated
receivers.
- Press the
button repeatedly to select the
receiver to be removed.
The associated blind will operate briefly.
10. Remove an association 11. Remove all associations
To remove all receivers associated with the sensor,
follow these instructions:
- Press and hold
the
button for
2 seconds.
- Press and hold the
button
for 2 seconds.
- The display will show
then switch off.
> 2s > 2s
9.1 Location
Install the Wind sensor near
the associated blinds.
The wind sensor cups must be
positioned horizontally and facing
downwards.
9.4 Maintenance and cleaning
To ensure optimum operation of the wind/sun sensor:
• Regularly check that the wind sensor is rotating freely.
• Ensure that the sun sensor is free of dust.
If necessary, clean the cover with a damp cloth.
(Do not use abrasive cleaning products or chemical so-
lutions which could damage the surface of the cover.)
90°
90°
9.2 Assembly
Adapt the hinged mount to your installation.
9.3 Installation
H2OH2O
Press and release the button to dis-
play the value set for the wind sensor.
  • Page 1 1
  • Page 2 2

DELTA DORE CV Installation guide

Type
Installation guide
This manual is also suitable for

DELTA DORE CV wind sensor can be best used when the user wants to automate control of outdoor blinds based on the wind speed and sunshine. The device can be associated with multiple receivers. This allows the user to control blinds in different locations or even control multiple blinds in one location. The device has a wind speed threshold setting that can be adjusted to protect the blinds from damage in high winds. The wind sensor also has a built-in sun sensor, which can be used to control the blinds based on the amount of sunlight. The DELTA DORE CV wind sensor is easy to install and use.