Daniel Flow Accessories-DRT-899 Pulse Input Rate/Totalizer User manual

Type
User manual
User manual
P/N 3-9008-800 / LIM6830DN_A, Rev A
April 2015
Daniel
DRT-899 Pulse Input Rate Totalizer
For Liquid Turbine Meters
Daniel customer service
Location Telephone number Fax number
North America/Latin America +1.713.467.6000 +1.713.827.4805
Daniel Customer Service +1.713.827.6314 +1.713.827.6312
USA (toll free) +1.888.356.9001 +1.713.827.3380
Asia Pacific (Republic of Singapore) +65.6777.8211 +65.6777.0947.0743
Europe (Stirling Scotland, UK) +44 (0)1786.433400 +44 (0)1786.433401
Middle East Africa (Dubai, UAE) +971 4 8118100 +971 4 8865465
Daniel Measurement and Control, Inc. (Headquarters)
11100 Brittmoore Park Drive
Houston, TX 77041 USA
http://www.daniel.com
Email
Customer Service: [email protected]
Customer Support: [email protected]
Asia-Pacific: [email protected]
Europe: [email protected]
Return Material Authorization (RMA)
A Return Material Authorization (RMA) number must be obtained prior to returning any equipment for any reason. Download the
RMA form from the Support Services web page by selecting the link below.
http://www2.emersonprocess.com/EN-US/BRANDS/DANIEL/SUPPORT-SERVICES/Pages/Support-Services.aspx
Signal words and symbols
Pay special attention to the following signal words, safety alert symbols and statements:
Safety alert symbol
This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol
to avoid possible injury or death.
DANGER!
Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING!
Warning indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION!
Caution indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Notice is used to address safety messages or practices not related to personal injury.
Important
Important is a statement the user needs to know and consider.
Tip
Tip provides information or suggestions for improved efficiency or best results.
Note
Note is “general by-the-way” content not essential to the main flow of information.
Important safety instructions
Daniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products to function within specific conditions.
Because these products are sophisticated technical instruments, it is important that the owner and operation personnel must
strictly adhere both to the information printed on the product and to all instructions provided in this manual prior to installation,
operation, and maintenance.
Daniel also urges you to integrate this manual into your training and safety program.
BE SURE ALL PERSONNEL READ AND FOLLOW THE INSTRUCTIONS IN THIS MANUAL AND ALL NOTICES AND PRODUCT WARNINGS.
WARNING!
Failure to follow the installation, operation or maintenance instructions for a Daniel product could lead to serious injury or death
from explosion or exposure to dangerous substances.
To reduce the risk:
Comply with all information on the product, in this manual, and in any local and national codes that apply to this product.
Do not allow untrained personnel to work with this product.
Use Daniel parts and work procedures specified in this manual.
Product owners (Purchasers):
Use the correct product for the environment and pressures present. See technical data or product specifications for
limitations. If you are unsure, discuss your needs with your Daniel representative.
Inform and train all personnel in the proper installation, operation, and maintenance of this product.
To ensure safe and proper performance, only informed and trained personnel should install, operate, repair and maintain
this product.
Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact
Daniel at 1-713-827-6314. You may also download the correct manual from: http://www.Daniel.com.
Save this instruction manual for future reference.
If you resell or transfer this product, it is your responsibility to forward this instruction manual along with the product to the
new owner or transferee.
ALWAYS READ AND FOLLOW THE INSTALLATION, OPERATIONS, MAINTENANCE AND TROUBLESHOOTING MANUAL(S) AND
ALL PRODUCT WARNINGS AND INSTRUCTIONS.
Do not use this equipment for any purpose other than its intended service. This may result in property damage and/or
serious personal injury or death.
Product operation (Personnel):
To prevent personal injury, personnel must follow all instructions of this manual prior to and during operation of the
product.
Follow all warnings, cautions, and notices marked on, and supplied with, this product.
Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact
Daniel at 1-713-827-6314. You may also download the correct manual from: http://www.daniel.com.
Read and understand all instructions and operating procedures for this product.
If you do not understand an instruction, or do not feel comfortable following the instructions, contact your Daniel
representative for clarification or assistance.
Install this product as specified in the INSTALLATION section of this manual per applicable local and national codes.
Follow all instructions during the installation, operation, and maintenance of this product.
Connect the product to the appropriate pressure and electrical sources when and where applicable.
Ensure that all connections to pressure and electrical sources are secure prior to and during equipment operation.
Use only replacement parts specified by Daniel. Unauthorized parts and procedures can affect this product's performance,
safety, and invalidate the warranty. “Look-a-like” substitutions may result in deadly fire, explosion, release of toxic
substances or improper operation.
Save this instruction manual for future reference.
Notice
THE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND WHILE EVERY EFFORT HAS
BEEN MADE TO ENSURE THEIR ACCURACY, THEY ARE NOT TO BE CONSTRUED AS WARRANTIES OR GUARANTEES, EXPRESSED OR
IMPLIED, REGARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICABILITY. ALL SALES ARE GOVERNED
BY DANIEL'S TERMS AND CONDITIONS, WHICH ARE AVAILABLE UPON REQUEST. WE RESERVE THE RIGHT TO MODIFY OR IMPROVE
THE DESIGNS OR SPECIFICATIONS OF SUCH PRODUCTS AT ANY TIME.
DANIEL DOES NOT ASSUME RESPONSIBILITY FOR THE SELECTION, USE OR MAINTENANCE OF ANY PRODUCT. RESPONSIBILITY FOR
PROPER SELECTION, USE AND MAINTENANCE OF ANY DANIEL PRODUCT REMAINS SOLELY WITH THE PURCHASER AND END-USER.
TO THE BEST OF DANIEL'S KNOWLEDGE THE INFORMATION HEREIN IS COMPLETE AND ACCURATE. DANIEL MAKES NO
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND, IN NO EVENT, SHALL DANIEL BE LIABLE FOR ANY INCIDENTAL,
PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFITS,
LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL, FUEL AND POWER, AND CLAIMS
OF THIRD PARTIES.
PRODUCT NAMES USED HEREIN ARE FOR MANUFACTURER OR SUPPLIER IDENTIFICATION ONLY AND MAY BE TRADEMARKS/
REGISTERED TRADEMARKS OF THESE COMPANIES.
Warranty and Limitations
1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement & Control, Inc. (“Daniel”)
warrants that the licensed firmware embodied in the Goods will execute the programming instructions provided by Daniel, and that
the Goods manufactured by Daniel will be free from defects in materials or workmanship under normal use and care and Services
will be performed by trained personnel using proper equipment and instrumentation for the particular Service provided. The
foregoing warranties will apply until the expiration of the applicable warranty period. Goods are warranted for twelve (12) months
from the date of initial installation or eighteen (18) months from the date of shipment by Daniel, whichever period expires first.
Consumables and Services are warranted for a period of 90 days from the date of shipment or completion of the Services. Products
purchased by Daniel from a third party for resale to Buyer (“Resale Products”) shall carry only the warranty extended by the original
manufacturer. Buyer agrees that Daniel has no liability for Resale Products beyond making a reasonable commercial effort to
arrange for procurement and shipping of the Resale Products. If Buyer discovers any warranty defects and notifies Daniel thereof in
writing during the applicable warranty period, Daniel shall, at its option, correct any errors that are found by Daniel in the firmware
or Services or repair or replace F.O.B. point of manufacture that portion of the Goods or firmware found by Daniel to be defective, or
refund the purchase price of the defective portion of the Goods/Services. All replacements or repairs necessitated by inadequate
maintenance, normal wear and usage, unsuitable power sources or environmental conditions, accident, misuse, improper
installation, modification, repair, use of unauthorized replacement parts, storage or handling, or any other cause not the fault of
Daniel are not covered by this limited warranty, and shall be at Buyer's expense. Daniel shall not be obligated to pay any costs or
charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by Daniel. All costs of dismantling,
reinstallation and freight and the time and expenses of Daniel's personnel and representatives for site travel and diagnosis under
this warranty clause shall be borne by Buyer unless accepted in writing by Daniel. Goods repaired and parts replaced by Daniel
during the warranty period shall be in warranty for the remainder of the original warranty period or ninety (90) days, whichever is
longer. This limited warranty is the only warranty made by Daniel and can be amended only in a writing signed by Daniel. THE
WARRANTIES AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE. THERE ARE NO REPRESENTATIONS OR WARRANTIES OF ANY
KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR ANY OTHER MATTER WITH RESPECT
TO ANY OF THE GOODS OR SERVICES. Buyer acknowledges and agrees that corrosion or erosion of materials is not covered by this
warranty.
2. LIMITATION OF REMEDY AND LIABILITY: Daniel shall not be liable for damages caused by delay in performance. The remedies of
Buyer set forth in this agreement are exclusive. In no event, regardless of the form of the claim or cause of action (whether based in
contract, infringement, negligence, strict liability, other tort or otherwise), shall Daniel's liability to Buyer and/or its customers
exceed the price to Buyer of the specific goods manufactured or services provided by Daniel giving rise to the claim or cause of
action. Buyer agrees that in no event shall Daniel's liability to Buyer and/or its customers extend to include incidental, consequential
or punitive damages. The term “consequential damages” shall include, but not be limited to, loss of anticipated profits, revenue or
use and costs incurred including without limitation for capital, fuel and power, and claims of Buyer's customers.
Contents
Part I Plan
Chapter 1 Introduction ..................................................................................................................3
1.1 Introduction ............................................................................................................................... 3
1.1.1 Model numbers and accessories ...................................................................................3
1.2 General settings ..........................................................................................................................4
1.3 Rate input settings ..................................................................................................................... 6
1.4 Rate/totalizer settings ................................................................................................................ 7
1.5 4-20 mA transmitter output settings .......................................................................................... 9
1.6 Open collector output settings ................................................................................................... 9
1.7 Serial communication settings ..................................................................................................10
1.8 Default settings for startup of DRT-899 .....................................................................................11
Chapter 2 Product certifications .................................................................................................. 13
2.1 Agency certifications ................................................................................................................13
2.2 Government installation regulations .........................................................................................14
Chapter 3 Product connections ................................................................................................... 15
3.1 Connection configuration .........................................................................................................15
3.2 Input signal connections .......................................................................................................... 16
3.3 DC power connection ............................................................................................................... 18
3.4 External reset connection ......................................................................................................... 18
3.5 4-20 mA transmitter output connections ..................................................................................19
3.6 RS-485 serial connections ......................................................................................................... 19
3.7 Open collector output connections ...........................................................................................20
Part II Install
Chapter 4 Installation requirements and limitations ....................................................................23
4.1 Requirements and limitations for installation ............................................................................23
4.2 Mounting dimensions ...............................................................................................................23
Part III Operate
Chapter 5 Setup and programming ............................................................................................. 27
5.1 Function keys and display for DRT-899 ......................................................................................27
5.2 DRT-899 button tips ................................................................................................................. 29
5.3 Set numeric values ....................................................................................................................30
5.4 Set alphanumeric labels (LAbEL) ................................................................................................30
5.5 Main menu for the DRT-899 ......................................................................................................31
5.6 Menu display functions for DRT-899 ......................................................................................... 32
5.7 Set up the meter .......................................................................................................................34
5.7.1 Select input type (InPut) .............................................................................................. 35
5.7.2 Enter the K-Factor (FActr) ............................................................................................37
5.7.3 Display units (UnitS) .................................................................................................... 38
Contents
User manual i
5.7.4 Set the decimal point (dEc.Pt) ..................................................................................... 45
5.7.5 Configure the display (dSPLY) .....................................................................................46
5.7.6 Custom tag (tAG) ........................................................................................................48
5.7.7 Set the toggle time (TIME) .......................................................................................... 49
Chapter 6 Product advanced features ..........................................................................................51
6.1 Advanced features menu .......................................................................................................... 51
6.2 Advanced features menu and display messages ........................................................................52
6.3 Open collector outputs (OUTPUT) ............................................................................................. 57
6.3.1 Output 1 and 2 Setup (OUT 1, OUT 2) ...........................................................................57
6.4 Scaling the 4-20 mA analog output (Aout) ................................................................................. 61
6.5 Gate function (GATE) ................................................................................................................ 62
6.6 Contact debounce filter (FILTER) ...............................................................................................63
6.7 Low-flow cutoff (CUTOFF) ......................................................................................................... 63
6.8 Scaling and calibration (SCALCAL) ............................................................................................. 63
6.8.1 Undo K-Factor, scale, and calibration (Undo?) ............................................................. 64
6.8.2 Scale the meter (SCALE) ............................................................................................. 64
6.8.3 Calibrate the meter (CAL) ........................................................................................... 66
6.8.4 Multi-point linearization (noPtS) ..................................................................................69
6.9 Total reset (T RESEt) ..................................................................................................................69
6.9.1 Manual or automatic total reset function (t rSt) ...........................................................69
6.9.2 Manual or automatic grand total reset function (GrtrSt) .............................................. 70
6.10 Set up passwords (PASSWRD) ....................................................................................................71
6.10.1 Lock meter setup parameters .....................................................................................72
6.10.2 Reset total and grand total on a password protected meter ....................................... 72
6.10.3 Disable password protection ...................................................................................... 72
6.10.4 Non-resettable grand total .........................................................................................73
6.11 Custom (CUSTOM) .....................................................................................................................74
6.12 System (SySTEM) .......................................................................................................................76
6.12.1 Set real time clock (SETTIME) ......................................................................................77
6.12.2 View data log (LOGVIEW) ............................................................................................ 79
6.12.3 Backlight (BAKLITE) .................................................................................................... 79
6.12.4 Analog output calibration (AO CAL) ............................................................................ 79
6.12.5 Backup and restore (BACkUP) ..................................................................................... 80
6.12.6 Battery power symbol alert (BAT SyM) .........................................................................81
6.12.7 Information (INFO) ..................................................................................................... 81
6.13 Serial communications (COMM) .................................................................................................81
6.14 Standby mode (STANDBy) ......................................................................................................... 82
6.14.1 Wakeup the meter (WAKEUP?) ................................................................................... 83
Chapter 7 Startup procedure ....................................................................................................... 85
7.1 Operation and startup procedure for DRT-899 ..........................................................................85
7.2 DRT-899 button tips ................................................................................................................. 87
7.3 Grand total reading (Gr TOTAL) ..................................................................................................87
7.4 Max/Min readings (MAXIMUM, MINIMUM) .................................................................................... 87
7.5 Reset the total (rESEt TOTAL?) ................................................................................................... 88
7.6 Reset the grand total (rESEt Gr TOT?) .........................................................................................88
7.7 Reset Max/Min readings (RESET MAXIMUM, MINIMUM) ................................................................ 88
7.8 Reset meter to factory defaults .................................................................................................89
7.9 Factory defaults and user settings .............................................................................................89
Contents
ii DRT-899
Part IV Maintain
Chapter 8 Maintenance of the DRT-899 ....................................................................................... 95
8.1 Troubleshooting tips .................................................................................................................95
8.2 Quick user interface reference .................................................................................................. 96
8.3 Battery replacement ................................................................................................................. 97
8.4 Recommended spare parts ....................................................................................................... 98
Contents
User manual iii
Contents
iv DRT-899
Part I
Plan
Chapters covered in this part:
Introduction
Product certifications
Product connections
Plan
User manual 1
Plan
2 DRT-899
1 Introduction
Topics covered in this chapter:
Introduction
General settings
Rate input settings
Rate/totalizer settings
4-20 mA transmitter output settings
Open collector output settings
Serial communication settings
Default settings for startup of DRT-899
1.1 Introduction
The Daniel Digital Rate Totalizer (DRT-899), 3-9008-800, is an explosion-proof pulse input
rate/totalizer fully featured for demanding applications in hazardous areas or in the
harshest environmental conditions. It can be programmed using the four through-glass
buttons, without removing the cover, or with four internal push-buttons.
The numeric rate display reads up to five digits and the alphanumeric total/tag display
reads up to 7 digits. The total overflow feature reads up to 12 digits. The alphanumeric
display can also be programmed to display any combination of numbers and letters up to
seven characters long for use as engineering units and/or the process identification tag.
The backlight increases the visibility of the display under various lighting conditions. The
enclosure contains threaded conduit holes and integrated pipe or wall mounting slotted
flanges.
1.1.1 Model numbers and accessories
These are the models and accessories that Daniel offers for the DRT-899.
Part number
DescriptionOIM Daniel
PD6830-BTA-I-DN 899-10-230-34 DRT-899-BTA-I-DN Exp-proof Pulse input Rate/Total-
izer. 24 VDC powered with battery backup. Isolated
ModBus Protocol enabled. Loop-Powered Backlight.
Isolated 4-20 mA output. 2 pulse outputs.
Introduction
User manual 3
Part number
DescriptionOIM Daniel
PD6830-DTB-0-DN 899-10-230-33 DRT-899-DTB-0-DN Exp-proof Pulse input Rate/To-
talizer. 4-20 mA powered with battery backup. Loop-
Powered Backlight. Non-isolated 4-20 mA output. 2
pulse outputs.
1.2 General settings
The settings below are general specifications for the DRT-899. Except when noted, all
specifications apply to operate at +25°C.
General settings Table 1-1:
Setting Description
Display Five digits Top display (0 to
99999)
17.8 mm (0.7") high, 7-segment, automatic
lead zero blanking.
Seven characters
Bottom display
10.2 mm (0.4")high, 14-segment, automatic
lead zero blanking.
Symbols Total, grand total, battery power/low battery,
high alarm, low alarm, button sleep mode/dis-
able, password lock
Display Assign-
ment
Top display: rate or total
Bottom display: Combinations of rate, total, grand total, units and custom tag
Backlight White LED, 10 second auto-off when battery powered
Backlight deactivated below temperatures -20° C
Alarm indication Flashing display plus HI/LO indicators
Display update
rate
Ambient > -25°C: 2 Update/Second
Ambient < -25°C: 1 Update/10 Seconds
Note: Update is dependent on gate settings.
Overrange Display flashes 99999
Underrange Display flashes -9999
Programming
methods
Four through-glass buttons when cover is installed. Four internal pushbuttons
when cover is removed.
Recalibration All ranges are calibrated at the factory to read frequency in Hz. No recalibration
required.
Max/Min display Max/Min readings acquired are stored until reset by the user or until power to
the meter is cycled.
Introduction
4 DRT-899
General settings (continued)Table 1-1:
Setting Description
Password menu
options
Three programmable password selections can restrict modification of pro-
grammed settings, prevent resetting the total or grand total without the pass-
word, or permanently lock out the ability to change or reset the grand total or
any grand total related settings, making a non-resettable grand total.
Pass: Restricts modifications of programmed settings without re-entering the
password.
Pass T: Restricts the reset of total without re-entering the password. Disables
the manual mode reset contact.
Pass GT: Restricts the reset of grand total without re-entering the password.
Enables a non-resettable total and permanent lockout of grand-total related
settings with a specific password.
Power options 9-30 VDC, 2.2 W max
4-20 mA Transmitter Output Power, 30 VDC max
Battery Power
DC Power with battery backup
4-20 mA Output Power with battery backup
Battery 3.6 V Primary Lithium (Li-SOCl
2
), non-rechargeable model 899-10-230-31
Expected Service Life and Recommended Replacement Interval
Operating Condition Estimated Service Life Suggested Replace-
ment Interval
Open collector outputs off,
through-glass buttons off,
minimal backlight use
7.5 years 5.5 years
<100 kHz open collector out-
puts, minimal through-glass
button or backlight use
5.5 years 4 years
<2 kHz open collector outputs,
minimal through-glass button
or backlight use
2.5 year 2 years
<5 kHz open collector outputs,
minimal through-glass button
or backlight use
1.3 year 1 year
Backup power only N/A 10 years
Data logging Up to 512 records, recorded four/day at specific times or at defined time inter-
vals. Record contains date, time, rate, total, grand total, and log number.
Isolation All Models 500 V opto-isolated input-to-power/output
with isolated input enabled
899-10-230-33 500 V input-to-output
899-10-230-34 500 V input/power-to-output
Note: Requires separate output supply
Introduction
User manual 5
General settings (continued)Table 1-1:
Setting Description
Environmental Operating temperature range: -40° C to 75°C
Storage temperature range: -40° C to 75°C
Backlight deactivated below temperatures -20° C
Relative humidity: 0 to 90% non-condensing
Non-volatile
memory
All programmed settings and total readings are stored in non-volatile memory
for a minimum of ten years if power is lost.
Connections Screw terminals accept 12 to 22 AWG wire
Enclosure Explosion-proof die-cast aluminum with glass window, corrosion resistant ep-
oxy coating, color: blue. NEMA 4X, 7, & 9, IP68. Copper-free (0.3%).
Default conduit connections: Three ¾" NPT threaded conduit openings. One ¾"
NPT metal plug with 12 mm hex key fitting installed. Additional conduit open-
ing configurations and plugs may be available; verify quantity and sizes on spe-
cific device labeling during installation.
Mounting The totalizer may be mounted directly to conduit by using slotted flanges for
wall mounting or NPS 1½" to 2½" or DN 40 to 65 mm pipe mounting. Note:
Certain sequences of events can cause unexpected results. To avoid unexpec-
ted issues, use factory defaults and anticipate the possibility of changes in the
mounting strategy.
Overall dimen-
sions
(144 mm x 133 mm x 124 mm)
5.67" x 5.24" x 4.88" (W x H x D)
Weight 5.00 lbs (80 oz, 2.27 kg)
1.3 Rate input settings
The settings below are rate input specifications for the DRT-899. Except when noted, all
specifications apply to operation at +25°C (+77°F).
Rate input settingsTable 1-2:
Setting Description
Pulse/ transistor/ con-
tact closure input
Field selectable; Sourcing or sinking pulse or square wave 0-5 V, 0-12 V,
or 0-24 V; TTL; NPN or PNP transistor
Open collector 100 kΩ pull-up to 3 V
Switch contact 100 kΩ pull-up to 3 V
PNP transistor 100 kΩ pull-down to ground (COM)
Active input 100 kΩ to battery level, 10 kΩ to power
Maximum Frequency: 64 kHz
Minimum Pulse Width: 5 μs
Threshold Setting Low (V) High (V)
Normal 1.2 1.8
Introduction
6 DRT-899
Rate input settings (continued)Table 1-2:
Setting Description
Low 0.2 1.0
Opto-isolated input Sourcing pulse or square wave 0-5 V, 0-12 V, or 0-24 V
Logic High: 2-24 V, Logic Low: < 1 V
Maximum Frequency: 20 kHz
Minimum Pulse Width: 20 μs
Input Current: 1 mA @ 5 V, 2.5 mA @ 12 V, 5 mA @ 24 V
Low voltage mag pick-
up input
Sensitivity: 20 mVp-p to 24 Vp-p
Maximum Frequency: 6 kHz
Minimum input fre-
quency
0.001 Hz. Minimum frequency is dependent on high gate setting (rate
display).
Input impedance Pulse input: Greater than 75 kΩ @ 1 kHz.
Open collector/switch input: 100 kΩ pull-up to 3 V.
Accuracy ±0.03% of calibrated span ±1 count
Temperature drift Rate display is not affected by changes in temperature.
Low-flow cutoff 0-99,999 (0 disables cutoff function)
Decimal point Up to four decimal places or none:
4.4444, 33.333, 222.22, 1111.1, or 00000
Calibration May be calibrated using K-Factor, scale without signal source, or by ap-
plying an external calibration signal.
K-Factor Field programmable K-Factor converts input pulses to rate in engineer-
ing units. May be programmed from 0.000001 to 9,999,999 pulses/unit.
Calibration range Input 1 signal must be ≥ 1 Hz; input 2 signal may be set anywhere above
input 1 setting.
Minimum input span is 1 Hz.
An Error message will appear if the input 1 and input 2 signals are too
close together.
Input contact de-
bounce filter
Programmable contact debounce filter. Input signal frequency speed se-
lections of Hi (no filter), Med (250 Hz max input, 2 ms pulse width), and
Low (100 Hz max input, 5 ms minimum pulse width).
Time base Second, minute, hour, or day
Gate Low gate: 1-99 seconds; High gate: 2-9,999 seconds
1.4 Rate/totalizer settings
The settings below are rate/totalizer specifications for the DRT-899. Except when noted,
all specifications apply to operation at +25°C (+77°F).
Introduction
User manual 7
Rate/totalizer settingsTable 1-3:
Setting Display
Display assignment The Top display calculates rate or total. The Bottom displays total; total and
units; total and tag; total, total units, and rate units; grand total; grand to-
tal and grand total units; grand total and tag; grand total, grand total units,
and rate units; rate units; rate; rate and total units; rate and rate units; rate
and tag; rate units; total units; a custom tag; or be off (blank).
Rate display units Gallons, liters, imperial gallons, cubic meters, barrels, bushels, cubic yards,
cubic feet, cubic inches, liquid barrels, beer barrels, hectoliters, or custom.
Rate display time
base
Display rate may be calculated in terms of units per second, minute, hour,
or day.
Total and grand total
display units
Gallons, liters, imperial gallons, cubic meters, barrels, bushels, cubic yards,
cubic feet, cubic inches, liquid barrels, beer barrels, hectoliters, or custom.
Setting is independent for each.
Total and grand total
display unit multipli-
er
x1, x100 (h), x1000 (k), or x1,000,000 (M) multiplier (and prefix) applied to
total or grand total display units. Setting is independent for each.
Total and grand total
decimal point
Up to six decimal places or none:
6.666666, 55.55555, 444.4444, 3333.333, 22222.22, 111111.1 or
0000000
Total and grand total decimal points are independently programmed, and
are independent of rate decimal point.
Totalizers Calculates total and grand total based on rate and field programmable mul-
tiplier to display total in engineering units. Time base must be selected ac-
cording to the time units in which the rate is displayed. The total and grand
total utilize the same time base, with different conversion factors and re-
sets.
Totalizer reset Via through-glass RESET button, manual button (cover off), external con-
tact closure (total only), automatically via user selectable preset value and
time delay (1 – 99,999 sec). Manual reset may be disabled or protected by
pass word for the total and grand total. Total and grand total reset inde-
pendently.
Total overflow and
rollover
The total can display up to 999,999,999,999. Up to 9,999,999 can normally
be displayed on the lower display. A rollover display toggles between the
first 6 digits and last six digits (999,999 <> 999,999) for a 12 digit total. The
total will rollover beyond 999,999,999,999.
Grand total overflow
and rollover
The grand total can display up to 999,999,999,999. Up to 9,999,999 can
normally be displayed on the lower display. A rollover display with toggle
between the first 6 digits and last six digits (999,999 <> 999,999) for a 12
digit grand total. The grand total will rollover beyond 999,999,999,999.
External total reset External reset connections are made between RST and COM. Logic High:
1.4V, 3.3V max; Logic Low: < 0.8V.
32 ms debounce.
Introduction
8 DRT-899
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112

Daniel Flow Accessories-DRT-899 Pulse Input Rate/Totalizer User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI