Power-Lite POWER-LITE WP36W-CC-E-MS LED Batten Microwave Motion Sensor is a unique lighting solution that offers automatic control, energy efficiency, and flexibility in various indoor settings. With its advanced microwave technology, it detects motion and adjusts lighting accordingly, making it ideal for areas like warehouses, offices, corridors, and public spaces. The sensor's customizable settings, including sensitivity, hold time, and daylight threshold, allow for tailored operation to suit specific needs.

Power-Lite POWER-LITE WP36W-CC-E-MS LED Batten Microwave Motion Sensor is a unique lighting solution that offers automatic control, energy efficiency, and flexibility in various indoor settings. With its advanced microwave technology, it detects motion and adjusts lighting accordingly, making it ideal for areas like warehouses, offices, corridors, and public spaces. The sensor's customizable settings, including sensitivity, hold time, and daylight threshold, allow for tailored operation to suit specific needs.

Certainty at The Speed of Light
SET-UP
INSTRUCTIONS
5.8GHz Microwave
MOTION SENSOR
WP18W-CC-MS
WP36W-CC-MS
WP36W-CC-E-MS
Features
Linear configuration antenna (only 11mm width), suitable for build in linear lighting fixture.
Tri-level dimming control.
Dual-PD technology, automatic lux on and lux off function.
Optional detection range, hold time and daylight threshold.
5 years warranty.
Dimensions (Unit: mm)
10
5
64
101.2
11.3 19
108
ø2.3
ø2.3
112.5
Mechanical Structure
Sensi
100%
1
50%
Stan
dimming le
d-by
vel
Hold Time
5s
2 3
90s
5min
10min
ON
OFF
10%
8
30%
DaylightSensor
Disable
4 5
50Lux
25Lux
10Lux
Stand-by period
0s
6 7
10s
15min
+∞
Antenna module Daylight sensor
Switch
Installation hole
Wiring Diagram
L
N
LED
Dimmable
Driver
L
N
PEGND
VCC
OUT
GND
VCC
DIM
GND FS007B
LED+
LED-
Detection Coverage
Detection area: 100%
3m
2m
1m
4m
5m
Ceiling Mounted
6m 5m 4m 3m 2m 1m 0m 1m 2m 3m 4m 5m 6m
Mounng
height
50%
Wall Mounted
1m 2m 3m 4m 5m 6m 7m 8m 9m 10m 12m 14m
3m
3m
2m
2m
1m
1m
Mounng
height
Technical Data
Operating voltage 12VDC
Input Operating current 40mA
Stand-by power
Output Output 5V PWM
Microwave frequency 5.8GHz±75MHz
Microwave power <0.3mW
Sensitivity 100%/50%
Sensor Hold time 5s/90s/5min/10min
Parameters Daylight threshold 10Lux/25Lux/50Lux/Disable
Stand-by period 0s/10s/15min/+∞
Stand-by dimming level 10%/30%
Mounting height Max.5m (ceiling mounted);
1.5-1.8m (Wall Mounted)
Detection range Radius: Max.6m (ceiling mounted);
Max.10m (Wall Mounted 1.8)
Operating temperature -25°C~+60°C
External wire length
500mm
IP rating
IP20
Note Size (L*W*H) 112.5*19*15 mm
Warranty 5 years
Other
≤0.5W
Settings
In this area,
movement will be
detected and able
to trigger the
sensor. 100%
detecon area is
also known as the
strong sensitvity.
The period of light
keeping 100% brightness
aer moving objects
leave the detecon area.
Definition of the ambient
brightness; only when the
ambient brightness is
lower than the preset
specific lux amount, the
sensor will work; when it's
preset as "disable", the
sensor works everyme it
detects motion
regardless the ambient
brightness.
The period of light
keeping low output before
it's completely switched
off. When it's preset as"∞“,
the light always keep at
low output if no
movement in the
detection area and
doesn't turn off.
The definition of
low output in
the stand-by
period.
0s
10s
DIP switch
Stand-by period
6 7
15min
+∞
5s
90s
DIP switch
Hold time
2 3
5min
10min
100%
50%
DIP switch
Sensitivity
1
10%
30%
DIP switch
Stand-by
dimming level
8
Disable
50Lux
DIP switch
Daylight threshold
4 5
25Lux
10Lux
12345678
ON
OFF
Daylight Priority
Thanks to the Dual-PD technology, the sensor can tell the difference between natural light
and artificial LED light.
The sensor will turn on your light fixtures when the ambient light is lower than the setting value,
even if no motion was detected. When the ambient light is up to the setting value, the sensor
will switch off the light fixtures even if there is still motion.
NoteLux-Off sampling time--30s
Lux-Off sampling time--10s
Lux-On function takes effect only when stand-by dimming period set at +∞.
Lux off
light on automatically
Sampling time
light off automatically
Lux on
Sampling time
Application Daylight Priority
① ②
With sufficient daylight, even
when motion detected, light
remains OFF.
Light automatically on when
ambient brightness is lower
than preset lux level.
With insufficient ambient
brightness, light dims to 100%
when motion detected.
Light dims to stand-by level if
no motion detected after hold
time.
Light off when ambient lux level
is higher than preset lux amount.
Application
With sufficient daylight, even
when motion detected, light
remains OFF.
With insufficient daylight, when
motion detected, light ON.
Automatically ON/OFF function
The sensitivity is set to 10Lux/25Lux/50Lux, Stand-by period is set to "0s".
After people leave the detection
area, light remains 100%
brightness within hold me.
After the last detection and the
preset hold time elapsed, light
OFF.
No daylight function
The sensitivity is set to "Disable". Light on when detect movement, After people
leave, Light off after stand-by period.
When moon is detected, the
sensor will switch on the light to
100% brightness.
Aer people leave the detecon
area, light remains 100%
brightness within hold me.
Aer the last detection and
the present hold time elapsed,
light OFF.
Application
Function Demo - Dimmable control/Corridor function
The sensitivity is set to "10Lux/25Lux/50Lux, stand-by period is set to "10s/15min".
① ②
With sufficient daylight, even
when motion detected, light
remains OFF.
With insufficient daylight, when
motion detected, light ON.
After people leave the detection
area, light remains 100%
brightness within hold time.
After last detection, the light will
be dimmed down to the
stand-by dimming level
10%/30% after hold time.
After the stand-by period, light
OFF.
Applications
Train station, Airport, etc.
Industrial Lighting: Factory, Warehouse etc.
Commercial Lighting: Office, Supermarket, etc.
Public Lighting: Residence, Hospital, School, Metro station
Celing Lamp / Bulkhead
Linear Light / Led Triproof Light
Warehouse Parking Corridor
Installation Precautions
Wiring must be strictly in accordance with the wiring diagram to avoid short circuit.
The detected surface cannot be shielded by metal objects.
Microwave sensor can be installed in any lamp except the one with full metal shell.
Should be kept away from the driver to avoid interference generation and lamp flashing.
Shall not be installed next to large oper
ating
machines such as ventilator/ceiling fan to
avoid false triggering caused by machine vibration.
Suitable for indoor installation to avoid false triggering due to external factors such as rain,
wind or tree swing.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Power-Lite POWER-LITE WP36W-CC-E-MS LED Batten Microwave Motion Sensor Operating instructions

Category
Motion detectors
Type
Operating instructions

Power-Lite POWER-LITE WP36W-CC-E-MS LED Batten Microwave Motion Sensor is a unique lighting solution that offers automatic control, energy efficiency, and flexibility in various indoor settings. With its advanced microwave technology, it detects motion and adjusts lighting accordingly, making it ideal for areas like warehouses, offices, corridors, and public spaces. The sensor's customizable settings, including sensitivity, hold time, and daylight threshold, allow for tailored operation to suit specific needs.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI