Danfoss Unloader flange valve, type EVRF - 032R9794 Installation guide

Type
Installation guide
Installation Guide
Unloader ange valve
Type EVRF
© Danfoss A/S (RC-MDP / RJA), 2014-10 DKRCC.PI.BH0.A2.02 / 520H9113 1
032R9794
032R9794
Refrigerants:
Oil with R717, R22/R407C, R404A/R507, R410A, R134a, R407A, R23.
For other refrigerants, please contact Danfoss.
Max. working pressure:
PS / MWP = 35 bar (508 psig)
Medium temperature:
Min. -40 °C (-40 °F) Max. 105 °C (221 °F)
EVRF
a.c. ~
a.c. ~
12 W a.c. ~
20 W d.c. –
a.c. ~
Clip-on coil
Warning
Never switch on power
to the coil when the
coil is dismounted from
the valve. Otherwise
the coil may be dam-
aged and there is risk of
injuries and burns.
Danfoss
32F909_EVRF
2 DKRCC.PI.BH0.A2.02 / 520H9113 © Danfoss A/S (RC-MDP / RJA), 2014-10
Danfoss
32F963_EVRF
A
[Nm] [kpm] [ft-lbs]
A 80 8.16 59
Cross tighten
Danfoss
32F961_EVRF
NC NO
  • Page 1 1