REED R2002 User manual

Category
Measuring, testing & control
Type
User manual
reedinstruments
www com
Model R2002
Infrared Thermometer
Instruction
Manual
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
reedinstruments
www com
2
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Table of Contents
Safety ............................................................................................ 3
Features ......................................................................................... 3
Specications ................................................................................ 4
Instrument Description .................................................................. 5
Operating Instructions ................................................................6-7
Battery Replacement ..................................................................... 7
For service on this or any other REED product or information on other
REED products, contact REED Instruments at [email protected]
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
reedinstruments
www com
3
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Safety
• Do not let the laser beam enter your eye, another person’s eye or the
eye of an animal
• Do not shine the laser beam off of a reective surface into your eye
• Do not direct the laser beam towards any gas that can explode
Features
• Precise non-contact temperature measurements
• Built-in laser pointer identies target area
• 8:1 Distance to Spot Size ratio
• Fixed emissivity covers 90% of all applications
• Automatic ambient temperature compensation
• Max/Min temperature display
• User selectable °F or °C
• Display backlight
• Automatic Data hold
• Trigger lock
• Low battery indication with auto shut off
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
reedinstruments
www com
4
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Specifications
Temperature Range: -58 to 932°F (-50 to 500°C)
Resolution: 0.1º
Accuracy: ±2% of reading or ±2°C (±4°F)
Sample Rate: < 1 sec.
Emissivity: 0.95 xed value
Field of View: Approx 8:1 distance to spot ratio with 90%
encircled energy at focal point
Diode Laser: Output <1mW, Wavelength 630~670nm,
class 2 (II) Laser product
Spectral Response: 6~14um
Power Off: 8 seconds of inactivity
Operating Temperature: 0 to 50ºC (32 to 122ºF)
Operating Humidity: 10 to 90% RH
Storage Temperature: -20 to 60ºC (-4 to 140ºF)
Storage Humidity: <80% RH
Power Supply: One 9V battery
Weight: 130g
Size: 131 x 82 x 35mm
Includes: Battery and carrying case
Optional Accessories: Accredited Calibration Certicate (CERTIIR1)
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
reedinstruments
www com
5
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Instrument Description
1. IR Sensor
2. Laser Pointer
3. LCD Display
4. °C/°F Button
5. Max/Min Button
6. Laser & Backlight Button
7. Trigger
8. Battery Cover
Display Description
1. Measuring Indicator
2. Data Hold
3. Laser Pointer
4. Fixed Emissivity Symbol
5. Temperature Unit
6. Low Battery Indicator
7. Max/Min Readout
8. Max/Min Symbol
9. Digital Readout
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
reedinstruments
www com
6
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Operating Instructions
1. Hold the meter and point it toward the surface to be measured
2. Pull and hold the Trigger to turn the meter on and begin measur-
ing, which is indicated by the SCAN icon on the LCD screen
3. Release the Trigger and the HOLD display icon will appear on the
LCD indicating that the current measurement is being held on the
screen
4. The meter will automatically power down after approximately 8
seconds of inactivity
Notes:
• The meter will take up to 30 minutes to adjust from high ambient
temperatures to low ambient temperatures
• Not recommended for measuring shiny or polished metal surfaces
(stainless steel, aluminum, etc)
• This meter cannot measure through transparent surfaces, it will
measure the surface temperature
• Steam, dust, and smoke can prevent accurate measurement by
obstructing the unit’s optics
Laser Pointer and Backlight
1. While taking a measurement, press the Laser & Backlight Button
once to turn on the laser pointer. The Laser icon will appear on the
display screen.
2. Press the Laser & Backlight Button twice to turn the display
Backlight
3. Press the Laser & Backlight Button three times to turn the laser off
4. Press the Laser & Backlight Button four times to turn both the
laser and backlight off
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
reedinstruments
www com
7
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Field of View
This meter’s eld of view is 8:1, meaning that if the meter is 8 inches from
the target the diameter of the object under test must be at least 1 inch in
size. The target needs to be larger than the unit’s spot size. The smaller
the target, the closer you should be to it. When accuracy is critical, make
sure the target is at least twice as large as the spot size. See below for
more information, or refer to the side of your meter for the same diagram.
Battery Replacement
1. Open battery cover
2. Remove the battery from the
meter and replace with a new
9-Volt battery
3. Replace the battery cover
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
reedinstruments
www com
8
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
1.800.561.8187 info@REED-Direct.ca REED-Direct.ca
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

REED R2002 User manual

Category
Measuring, testing & control
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI