2 Installation
2.1 Installation Position Requirements
Theminimumspacerecommendedmustbesufficienttokeepthat
safetyspaceinalldirectionsfortheoperatortoworkproperly.
2.2 Pneumatic Installation
Themachinehasanairinletvalve,typequickactingcoupler(ISO6150-
Bstandard)8mm,locatedonthebackofthemachine.
Foranoptimaloperation,thesupplyofcompressedairshouldbe6kg/cm2,adjusted
withapressuregaugethatcustomer’swillhaveinstalledonitscompressor.
2.3 Transport
Ifitisnecessarytotransportthemachineagainafteritsinstallationandthecustomerdoesnot
havetheoriginalpackaging,weadvicetouseareinforcedpackage(woodorcardboard).
2.4 And Holding The Box Firmly
Beforeanyoperationwiththeequipment,themachinemustbeproperlyfixedtothebench
(fromthecustomer)with4xM8screws(8.8quality),washersandself-lockingnuts.
2.5 Learning Instructions
ThefollowingsetofinstructionsandwarningsaboutEMBLEMEasy
AIRPRESSStandardshouldalwaysbetakeninaccount:
Beforeconnectingthemachinetothecompressorortocustomer’s
pneumaticinstallation,itshouldbeplaceonitspermanentlocation.
• Thecleaning,handlingorreplacementofpartsshould
alwaysbemadewiththeairinletvalveshut.
• Donotremovefromthemachinethesafetydevices,stickers
orwarningsignsthatpointoutdangerousareas.
• Themachinehasanairinletvalvetomanuallyopenandclosetheairsupplyto
thepneumaticcylinder“F”(Fig.1);Whenthemachineisnotinuse,itshouldbe
shut(seeFig.5),toavoidaccidentswhenusebyathirdparty.Wealsosuggest
disconnectingthehosepipefromthecompressorforsafetyreasons.