Intelbras 8000 Slim System User guide

Type
User guide
Installation/user guide
AMT 8000 Slim
AMT 8000 Slim
Wireless theft alarm system
Congratulations, you have just purchased a product with Intelbras quality and safety.
The AMT 8000 SLIM alarm system is a solution against intrusion. Composed by the AMT 8000 alarm panel,
XSS 8000 siren, XAC 8000 remote control, IVP 8000 PET motion sensor and XAS 8000 aperture sensor, offers
protection with maximum security. With long-range fully wireless communication, it is not necessary to change
the structure of the residence for installation.
Summary
AMT 8000 - Alarm center 6
1. Technical Specications 8
2. AMT 8000 Alarm Center Features 8
3. AMT 8000 Accessories 9
3.1. GPRS XAG 8000 Module and GSM XAG 8000 3G Module ............................................9
3.2. Communication module via telephone line - FXO 8000 .............................................10
3.3. Wireless keyboard for alarm centers– XAT 8000 ..................................................10
3.4. XAC 8000 remote control ...................................................................11
3.5. Wireless siren - XSS 8000 ...................................................................12
3.6. Wireless magnetic sensor - XAS 8000 ..........................................................12
3.7. Passive infrared wireless sensor - IVP 8000 Pet ....................................................13
3.8. Passive infrared wireless sensor - IVP 8000 Pet Cam ................................................14
3.9. Universal Transmitter – TX 8000 ...............................................................14
4. Installation of the alarm center and its peripherals 16
4.1. Power supply for the alarm center (full range 90 and 265 Vac) ........................................18
4.2. Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
4.3. XAG 8000 GPRS Module ....................................................................19
4.4. FXO 8000 Phone Module ....................................................................19
4.5. AMT 8000 Alarm Center ....................................................................19
5. Operation 20
5.1. Description of the XAT 8000 LCD keyboard indications ..............................................20
5.2. Display of troubles ........................................................................20
5.3. Description of the LEDs signaling on the alarm center boards .........................................20
5.4. Partitioning ..............................................................................21
5.5. Activation/deactivation of the alarm center .......................................................21
5.6. Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
5.7. Remote update ...........................................................................26
6. Programming 26
6.1. Programming mode .......................................................................26
6.2. Wireless devices (register/delete) ..............................................................28
6.3. Wireless sensor functions ....................................................................33
6.4. Functions of Remote Control Keys .............................................................34
6.5. Functions of Wireless Keyboard ...............................................................36
6.6. Siren functions ............................................................................38
6.7. Update .................................................................................40
6.8. Passwords ...............................................................................40
6.9. Quick setup for SMS monitoring and programming .................................................44
6.10. Zone settings ............................................................................48
6.11. Programming the alarm center partitioning ......................................................51
6.12. Timings ................................................................................52
6.13. Alarm Center Time Settings .................................................................53
6.14. Periodic Test .............................................................................55
6.15. Autoactivation ...........................................................................56
6.16. Telephony and Monitoring Settings ............................................................59
6.17. Functions via SMS ........................................................................76
6.18. Activation/deactivation of Functions ..........................................................79
6.19. Time to send the AC fault ...................................................................82
6.20. System Reset ...........................................................................83
6.21. Quick programming reference ...............................................................83
XSS 8000 - Wireless siren 98
Care and security 99
1. Technical specications 100
2. Features 100
3. Initial battery activation 100
4. Register 101
5. Installation 102
6. Operation 102
7. Battery 102
8. Homologation 103
XAS 8000 - Magnetic sensor 104
1. Care and security 105
1. Technical specications 106
2. Features 106
3. Product 106
4. Installation 107
5. Identifying the best place for installation 107
6. Fixing the XAS 8000 sensor 108
7. Conguring the LED through the center unit keyboard 108
7.1. Information on LED operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108
7.2. Conguring the LED through the application ....................................................108
8. Battery 110
9. Homologation 110
IVP 8000 PET - Infrared passive sensor 111
1. Care and security 112
1.1. Scan (upper view) ........................................................................113
1.2. Detection range (side view) .................................................................113
1. Technical specications 114
2. Features 114
3. Product 115
4. Registering the IVP 8000 PET sensor 115
4.1. Deleting the sensor register .................................................................115
5. Identicando o melhor local para a instalação 116
6. Installation 116
7. Conguring the IVP 8000 PET sensor 117
7.1. Conguring the sensor through the keyboard ....................................................117
7.2. Information on sensor settings ...............................................................117
7.3. Conguring the sensor through the application ..................................................118
8. Battery 119
9. Homologation 119
XAC 8000 - Remote control 120
1. Care and security 121
1. Technical specications 122
2. Features 122
3. Register 123
4. Handling 123
5. Battery 124
6. Homologation 124
Warranty term 125
AMT 8000
Alarm center
AMT 8000 Wireless Alarm Center has advanced technology and is easy to program. Due to its differentiated technology, the
following unique wireless devices can be connected to this center: XAC 8000 remote control, XAS 8000 magnetic wireless
sensor, IVP 8000 Pet passive wireless sensor, IVP 8000 Pet Cam passive wireless sensor, XSS 8000 wireless siren, wireless
keypad for XAT 8000 alarm center, REP 8000 range RF amplier and also the TX 8000 universal transmitter with all devices
exchanging information with encryption, for greater system security. In addition to various security devices such as tamper
against removal of the installation surface and violation of devices and with long battery life. This center has 16 partitions,
8 memories for phone numbers,
Panic
function,
Emergency
function, smart battery charger with protection against short
circuit or polarity reversal, timing and sensor test function. The system has differentials such as high performance wireless
device communication (bidirectional) with a range of up to 1000 meters without barriers and direct view, GPRS and
GSM type connections, telephone line, Ethernet and Wi-Fi connection to provide greater ease for system monitoring and
checking. Reports events to 2 IP destinations (monitoring companies). The center is already directed to the Intelbras Cloud
using initially the random remote access password indicated along with the QR Code label that also contains the MAC.
AMT 8000 Center has remote software update (rmware), using Ethernet cable or Wi-Fi communication to download the
most updated rmware version.
In addition to this option, the center can also be updated using the BootLoader feature. To do this, you need to have the
Atualizador 8000
software previously installed on your computer.
Care and security
» Follow all instructions in the manual for product installation and handling.
» Perform the installation in environments not susceptible to factors such as rain, fog and splashes of water.
» Wireless communication technology, when exposed to environments with high power radiation, may suffer interference
and have its performance impaired. Example: places near TV towers, AM/FM radio stations, amateur radio stations, etc.
» Do not install the control panel and its accessories near radio frequency equipment such as routers, repeaters and / or wi-
 signal ampliers. The control panel and its devices must maintain a minimum distance of 2 meters from this equipment.
» Do not install the alarm center facing air conditioning or heating equipment.
» Do not expose directly to sunlight.
» Clean only the external part of the device, using only a damp cloth (do not use chemical solvents).
» Do not subject the device to excessive pressure or knocks/falls.
» Do not cover the device with adhesives, paper or inks.
» Check that at the installation site, the LED indicating the devices ash green when activated.
» Avoid installation on metal surfaces in order not to attenuate the transmission signal between the devices in the system.
» The installation, conguration of the center and the other products that make up this system must be performed by a
qualied professional.
» Perform periodic tests on it in order to validate weather conditions, battery level and other factors, so that the site super-
vised by the system is always able to operate correctly.
» LGPD - General Law for the Protection of Personal Data: this product handles personal data, but Intelbras does not
» has access to data from this product.
8
1. Technical Specications
Product Monitored alarm center
AC power 90 to 265 V (we recommend the use of a cable with gauge ≥ 1 mm)
DC power 5.7 V coming from XFT 8000 source
Battery 3.7 Vdc rechargeable battery (supplied with alarm center)
Operating temperature –10 °C to 50 °C @ 90% humidity
Weight 568 grams (with battery and other accessories connected - XAG and FXO)
Dimensions (W × H × D) of Product: 84 × 290 × 273 mm
With individual packaging: 90 × 292 × 276 mm
Average power¹
AMT 8000: 5.2 Watts
AMT 8000 + FXO 8000: 5.8 Watts
AMT 8000 + XAG 8000: 8.1 Watts
AMT 8000 + FXO 8000 + XAG 8000: 8.2 Watts
Antenna type: internal
Antenna gain: 0 dBi
Wireless communication frequency
AMT 8000/Accessories 915 to 928 MHz via internal antenna, power 18 dBm
Modulation DSSS BPSK 40 Kbps
Battery 3.7 Vdc lithium rechargeable, internal
Optional²
XAC 8000 remote control
REP 8000 Range RF Amplier
XAT 8000 Wireless Keyboard
XAS 8000 Wireless Magnetic Sensor
TX 8000 Universal Transmitter
IVP 8000 Pet passive infrared wireless sensor
IVP 8000 Pet Cam passive infrared wireless sensor
FXO 8000 Telephone Line Module
XAG 8000 GPRS Module
XSS 8000 Wireless Siren
XAG 8000 3G GSM Module
1
Conditions: maximum power veried with alarm center activated, with registered peripherals (keyboards/sensors/sirens) and with the
means of communication connected and operating in conjunction with the center. In some operations the consumption may vary ac-
cording to the number of peripherals operating in the security system and their information exchange (
Stand by
- continuous mode).
² Optional: for more information see the website
www.intelbras.com.br.
Attention: Intelbras wireless systems are tested to the highest standards and bring high reliability, however, due to their
use/installation in various scenarios, some considerations must be taken into account:
» Transmitters/receivers may be being disturbed by radio signals, natural interference, location of device operation, climatic
issues and other adversities that affect the transmission of data regardless of the frequency or technology used, since the
means of transmission is adverse and different from place to place.
» Receivers/transmitters of the devices have an internal processing time, and only receive the data necessary for commu-
nication between them after this particular time for the system.
» Wireless devices must be tested regularly to determine if sources of interference exist and to protect against possible
failures.
2. AMT 8000 Alarm Center Features
» Capacity for 16 partitions with independent activations/deactivations.
» Zone allocation according to the desired partitions.
» Wireless signal receiver/transmitter integrated into the alarm center operating with a frequency from 915 to 928 MHz.
» Support for 2 (SIM card) mobile phone chips with XAG 8000 module installed.
» Quad-band GPRS modem: compatible with most national GSM operators for AMT 8000 operating with XAG 8000 and
XAG 8000 3G module (sold separately).
» Event reporting via Ethernet / Wi-Fi connection, telephone line (with FXO 8000 module installed - sold separately), GPRS connection
(with XAG 8000 module installed - sold separately) and GSM connection (with XAG 8000 3G module installed - sold separately).
9
» Remote access from the alarm center via applications and services (telephone and SMS - requires communication mo-
dules).
» Use in connection with all wireless devices on the 8000 line.
» Ability to display and program parameters by up to 16 XAT 8000 keyboards.
» Ability to connect up to 16 XSS 8000 wireless sirens.
» Ability to connect up to 98 XAC 8000 controls with user identication.
» Ability to connect up to 64 wireless sensors of the 8000 line.
» Remote programming via fax/modem card, Ethernet, Wi-Fi, GPRS and GSM.
» Ability to connect up to 04 REP 8000 RF ampliers.
» Programming for up to 97 passwords including duress with congurable permissions.
» Monitorable by Contact-ID protocol.
» Supervision of sensors, sirens and keyboards.
» Low battery detection of registered wireless devices.
» Internal buffer for 512 events.
» Remote software update through Ethernet or Wi-Fi connections.
3. AMT 8000 Accessories
AMT 8000 alarm center can have several accessories grouped to compose the monitoring and security system, with the
accessories responsible for communication and monitoring, sound warning, LCD keyboard and several sensors, for better
adequacy and composition of the necessary protection system.
3.1. GPRS XAG 8000 Module and GSM XAG 8000 3G Module
Optional accessory dedicated for data transmission via GPRS / GSM for communication, conguration and reporting of
events between user and / or monitoring company with the AMT 8000 security system.
Features
» Supports up to two SIM card type chips.
» 2G GPRS communication with the XAG 8000 module and 2G / 3G communication with the XAG 8000 3G module.
» External antenna with 0 dBi gain.
» Reports events to 2 IP destinations (monitoring company) plus the Intelbras cloud.
» Operates with xed or dynamic IP.
» Connections to DNS destinations.
» Power from the AMT 8000 alarm panel.
The following gure shows the illustrative image of the XAG 8000 and XAG 8000 3G modules:
ST
100
25V
GPRS XAG 8000 Module and GSM XAG 8000 3G Module
10
Note:
the XAG 8000 and XAG 8000 3G modules are compatible with most national GPRS / GSM operators with 2G and
3G technology and can only be used with the AMT 8000 alarm panel.
3.2. Communication module via telephone line - FXO 8000
Optional accessory dedicated to data transmission via telephone line for communication and event reporting to a
monitoring company with the AMT 8000 security system, in addition to dialing up to 5 personal phones and emitting the
sound of a siren from the telephone line.
Features
» Up to 8 programmable phone addresses.
» DTMF type dialing mode.
» Telephone line cut/interruption check.
» Contact-ID communication protocol.
» Power supply from the AMT 8000 alarm center.
The following gure shows the illustrative image of the FXO 8000 module:
+
10
50G
682
FX8000
4640353/P/4P
108XXXX
LINHA FONE
FXO 8000 Telephone Line Module
3.3. Wireless keyboard for alarm centers– XAT 8000
Optional dedicated accessory to congure, check status and operate the AMT 8000 alarm center. Communication between
the keyboard and the center is made through a wireless signal, providing a simpler installation and long communication
range. Up to 16 XAT 8000 keyboards can be added to each AMT 8000 alarm center.
Features
» Monochrome character liquid crystal screen with 3 lines:
» 1st line for graphic icons (alarm center battery charge indication, problem indication and siren activated).
» 2nd message line with 14 segments.
» 3rd message line with 14 segments.
» Keyboard with illumination on the keys.
» Cover for protection against accidental activation of the keys.
» Light sensor to activate the illumination of the display and keys.
» Display of problems.
» Wireless communication with the alarm center (915 to 928 MHz) via internal antenna, power 11 dBm.
» Simplies the programming of the alarm center.
» Text message display.
» Display of the battery level of the alarm center.
» Display of zone status (open/closed).
» Signs the status of the partitions.
»
Panic, Medical Emergency
and
Fire
function.
» Violation protection (tamper).
11
» Sound signalling during operation.
» DC Power:4 batteries 3 Vdc (CR2450) included.
» Communication supervision and encrypted transmission.
» Range: up to 600 m with direct view in open eld.
The following gure shows the illustrative image of the keyboard:
1 2 3
4 5 6
7 8
0
9
XAT 8000 Wireless Keyboard
The keyboard has two tamper keys, one of which is located on the front of the keyboard, under the cover, is activated by
moving the keyboard cover, its function is to activate the keyboard and the other key, located on the back of the keyboard
cabinet is functioning as tamper (violation protection). On the front of the XAT 8000 there is the light conductor for the
brightness sensor, which has the function of controlling the intensity of the display and keyboard for battery optimization.
The keyboard can be installed on different surfaces, always placing it in the vertical position in relation to the oor and
using double-sided tape or screws (not included) to x the base and after attaching the device, tting and checking that it
was placed correctly so that there are no falls and damage.
3.4. XAC 8000 remote control
Optional dedicated accessory for interface between user and alarm center. Allows to activate, deactivate and perform other
functions together with the alarm center with three keys and light identication of events. Up to 98 XAC 8000 controls can
be added for each AMT 8000 alarm center.
Features
» Visual indication of communication with the system through a two-color LED.
» 3 programmable buttons.
» Wireless communication with the alarm center (915 to 928 MHz) via internal antenna.
» Power 11 dBm.
» DC Power Supply:1 internal 3 Vdc (CR2032) battery of long duration.
» Encrypted transmission.
» Range: up to 200 m with direct view in open eld.
The following gure shows the illustrative image of the control:
XAC 8000 remote control
12
3.5. Wireless siren - XSS 8000
Optional dedicated accessory for status audible warning, intrusion and emergency indications from the AMT 8000 alarm
center. Communication between the siren and the center is made through a wireless signal, providing a simpler installation
and long communication range. Up to 16 XAC 8000 sirens can be added for each AMT 8000 alarm center.
» Features Sound power from 100 dB to 1 meter.
» Communication status check through LED.
» Audible trigger if communication is lost with the alarm center.
» Wireless communication with the alarm center (915 to 928 MHz) via internal antenna, power 11 dBm.
» DC Power Supply:1 Li-SoCl2 3.6 V / 14 A non-rechargeable battery with wire/connector - included.
» Communication supervision and encrypted transmission.
» Range: up to 600 m with direct view in open eld.
The following gure shows the illustrative siren image:
XSS 8000 Wireless Siren
XSS 8000 siren has a tamper key against violation, located at the back of the siren, and if this key is opened/violated,
registered sirens will trigger and send the corresponding event if the
Problems that generate trigger
function is enabled
(see section
Problems that generate trigger
).
Siren can be installed on several surfaces, always placing it in a vertical position with a height between 1.80 and 2.20
meters from the oor and using double-sided tape or screws (not included) to x the base and after securing the device,
tting and checking that it has been placed correctly so that there are no falls and damage. The status of the siren
communication with the alarm center will be represented on it through the indicator LED located on the front, and when
in normal communication the LED will ash green, with partial communication orange and no communication red (the
indicator LED after 15 minutes will enter hibernation mode for battery saving, not hindering the device communication and
to activate again press the device synchronisation key once).
3.6. Wireless magnetic sensor - XAS 8000
Optional dedicated accessory for door and window open checking in a distinctive, discreet and compact design. With low
battery indication and sensor communication status, supervision, activation and anti-violation system with internal tamper
to compose the 8000 line security system with maximum results.
Features
» Wireless communication with the alarm center (915 to 928 MHz) via internal antenna, power 11 dBm.
» Communication status check through LED.
» Fastening by screws (not included) or double-sided tape (not included).
» DC Power Supply:1 CR2450 type 3 Vdc battery of long life lithium.
» Communication supervision and encrypted transmission.
» Range: up to 600 m with direct view in open eld.
13
The following gure shows the illustrative image of the XAS 8000 sensor:
XAS 8000 aperture sensor
XAS 8000 sensor has a tamper key against violation, and if this key is opened/violated, registered sirens will trigger and
send the corresponding event if the
Problems that generate trigger
function is enabled (Problems that generate trigger).
The status of the sensor communication with the alarm center will be represented on it through the indicator LED located
on the front, and when in normal communication the LED will ash green, with partial communication orange and no
communication red (the indicator LED after 15 minutes will enter hibernation mode for battery saving, not hindering the
device communication and to activate again press the device synchronisation key once).
3.7. Passive infrared wireless sensor - IVP 8000 Pet
Dedicated accessory for checking intrusions through infrared reading in indoor environments, in a discreet and compact
way and taking into account the presence of a pet and not triggering the alarm. With low battery indication and sensor
communication status, supervision, activation and anti-violation system with internal tamper to compose the 8000 line
security system with maximum results.
Features
» Wireless communication with the alarm center (915 to 928 MHz) via internal antenna, power 11 dBm.
» Communication status check through LED.
» Coverage of 12 meters by 90°.
»
Pet
function with detection ≥20 kg.
» Fastening by screws (not included) or double-sided tape (not included).
» DC Power Supply:1 CR123A type 3 Vdc battery of long life lithium.
» Communication supervision and encrypted transmission.
» Range: up to 600 m with direct view in open eld.
The following gure shows the illustrative image of the IVP 8000 sensor:
IVP 8000 Pet presence sensor
14
IVP 8000 Pet sensor has a tamper key against violation, and if this key is opened/violated, registered sirens will trigger and
send the corresponding event if the
Problems that generate trigger
function is enabled (see section
Problemas que geram
disparo
). The status of the sensor communication with the alarm center will be represented on it through the indicator LED
located on the front, and when in normal communication the LED will ash green, with partial communication orange and
no communication red (the indicator LED after 15 minutes will enter hibernation mode for battery saving, not hindering
the device communication and to activate again press the device synchronisation key once).
3.8. Passive infrared wireless sensor - IVP 8000 Pet Cam
Dedicated accessory for checking intrusions through infrared reading in indoor environments, in a discreet and compact
way and taking into account the presence of a pet and not triggering the alarm. It has a camera that after the sensor
triggering, sends the image of the site to the applications and software compatible with the AMT 8000 Alarm Center. With
low battery indication and sensor communication status, supervision, activation and anti-violation system with internal
tamper to compose the 8000 line security system with maximum results.
Features
» Wireless communication with the alarm center (915 to 928 MHz) via internal antenna, power 11 dBm.
» Communication status check through LED.
» Coverage of 12 meters by 90°.
»
Pet
function with detection ≥20 kg.
» Takes two pictures per shot. Attending therefore light and dark environments / night period.
» Fastening by screws (not included) or double-sided tape (not included).
» DC Power Supply:2 CR123A type 3 Vdc batteries of long life lithium.
» Communication supervision and encrypted transmission.
» Range: up to 600 m with direct view in open eld.
The following gure shows the illustrative image of the IVP 8000 Pet Cam sensor:
Presence sensor with IVP 8000 Pet Cam camera
IVP 8000 Pet Cam sensor has a tamper key against violation, and if this key is opened/violated, registered sirens will
trigger and send the corresponding event if the
Problems that generate trigger
function is enabled (see section
Problems
that generate trigger
). The status of the sensor communication with the alarm center will be represented on it through the
indicator LED located on the front, and when in normal communication the LED will ash green, with partial communication
orange and no communication red (the indicator LED after 15 minutes will enter hibernation mode for battery saving, not
hindering the device communication and to activate again press the device synchronisation key once).
3.9. Universal Transmitter – TX 8000
Optional accessory dedicated to receive wired sensor signals and transmission of this reading to the AMT 8000 alarm
center. The operation of this device is the same as that of a XAS 8000 wireless magnetic sensor, but it will be activated
every time another sensor has an opening/closing and sends the signal via a pair of wires of the dry contact type (NO or
NC), thus transforming a wired sensor into a wireless one.
15
Features:
» Wireless communication with the alarm center (915 to 928 MHz) via internal antenna, power 11 dBm.
» Communication status check through LED.
» Fastening by screws (not included) or double-sided tape (not included).
» DC Power Supply:1 CR2450 type 3 Vdc battery of long life lithium.
» Communication supervision and encrypted transmission.
» Range: up to 600 m with direct view in open eld.
The following gure shows the illustrative image of the TX 8000 transmitter:
TX 8000 Wired Sensor Transmitter
TX 8000 transmitter has a tamper key against violation, and if this key is opened/violated, registered sirens will trigger and
send the corresponding event if the
Problems that generate trigger
function is enabled (see section
Problemas que geram
disparo
). The status of the sensor communication with the alarm center will be represented on it through the indicator LED
located on the front, and when in normal communication the LED will ash green, with partial communication orange and
no communication red (the indicator LED after 15 minutes will enter hibernation mode for battery saving, not hindering
the device communication and to activate again press the device synchronisation key once).
Attention: the sensors can be installed on different surfaces, always respecting the best position and height for the sensor
to read data correctly. Use double-sided tape or screws (not included) to x the base and after attaching the device, tting
and checking that it was placed correctly so that there are no falls and damage. Observe the maximum communication
distance of the devices with the alarm center.
Range RF Amplier (REP 8000 Repeater)
Optional dedicated accessory for amplifying the RF range between the AMT 8000 alarm center and the other devices.
Communication between the repeater and the center is made through a wireless signal, providing a simpler installation
and long communication range. Repeater can be installed at a distance of 600 meters from the alarm center without
barriers and the other devices at 600 meters from the repeater, also without barriers. Extending the range of the alarm
center from 600 m to 1200 m without barriers.
Features:
» Range: up to 600 m with direct view in open eld.
» Amplier of the coverage area of the AMT 8000 system.
» Protection against malicious signals.
» Cryptography in data transmission between devices.
» Easy installation and handling.
» Amplication of the RF signal up to 600 meters beyond the maximum limit for communication with the alarm center, so
with the use of the amplier a device can communicate at a distance of up to 1.2 kilometers with the alarm center in the
case of direct view and without barriers.
» Rechargeable battery.
» Includes 7 Vdc/500 mA source.
Important: each AMT 8000 alarm center can have up to 4 repeaters operating simultaneously, but all in separate
operation from each other, so there is no possibility of one repeater being used to extend the signal to another, only in
direct use between devices and alarm center.
16
The following gure shows the illustrative image of the repeater:
Range RF Amplier (REP 8000 Repeater)
Range RF Amplier (REP 8000 Repeater) has a tamper key against violation, located at the back of the repeater, and if this
key is opened/violated, registered sirens will trigger and send the corresponding event if the
Problems that generate trigger
function is enabled (see the
Problems that generate trigger
section).
The installation of the Range RF Amplier (REP 8000 Repeater) can be on various surfaces, always placing it in a vertical
position with a height between 1.80 and 2.20 meters from the oor and using double-sided tape or screws (not included)
to x the base and after securing the device, tting and checking that it has been placed correctly so that there are no
falls and damage. The status of the repeater communication with the alarm center will be represented on it through the
indicator LED located on the front, and when in normal communication the LED will ash green, with partial communication
orange and no communication red (the indicator LED after 15 minutes will enter hibernation mode for battery saving, not
hindering the device communication and to activate again press the device synchronisation key once).
4. Installation of the alarm center and its peripherals
Attention: only connect the AMT 8000 alarm center to the mains and battery after the installation of all equipment and
peripherals.
Open the product box and then open the cover of the AMT 8000 alarm center cabinet by removing the screws, where two
plates can be seen, that is, its basic conguration contains the AMT 8000 alarm center board and its respective power
supply and rechargeable battery that comes with the system.
telephone, GPRS and GSM, these cards with their respective interconnection cables with the AMT 8000 exchange.
If you choose the full conguration, 4 boards must be installed in the alarm center cabinet (the alarm center board, the
source board, the telephone line module and the GPRS module or GSM module).
AMT 8000 alarm center has only wireless zones, as well as other accessories (keyboard, sirens, etc.) are connected to the
alarm center via wireless signal, with only the AC power cables, telephone line and Ethernet network cable connected to
the alarm center.
17
Image below illustrates the alarm center with all the devices that can be physically connected:
AMT8000
SENTIDO DE SOLDA
12524
23
22
2
3
4
5
6
7891011
12
1314
15
16
18
19
20
21
17
26
AMT 8000 Alarm Center
1. Connector for network cable (Ethernet).
2. CPU card of the AMT 8000 alarm center.
3. Mini-USB type connector for alarm center rmware update.
4. Alarm center CPU card indicator LED.
5. Alarm center board connector for interconnecting the FXO 8000 telephone line module.
6. Alarm center board connector for interconnecting the XAG 8000 GPRS/GSM module.
7. Pin-type connector (2×5-way) for rmware update of the alarm center.
8. Key for wireless device registration.
9. Input connector for telephone line.
10. Output connector for telephones.
11. CPU board for FXO 8000 telephone line module.
12. Flat cable connector for the XAG 8000 module.
13. Connector for SIM 1 card and SIM 2 card.
14. Connector for external antenna of the XAG 8000 GPRS module.
15. CPU card of the XAG 8000 GPRS module.
16. External GSM antenna (included with XAG 8000 module).
17. Connector for at cable for the output of the telephone line signal to the alarm center board.
18. 3.7 V battery.
19. Flat cable connector for DC output from power supply.
20. Input connector for two-way battery cable.
21. XFT 8000 power supply board.
22. Protection fuses (2 x 250 Vac/400 mA).
23. Connector to connect the ground to the power supply (ground).
24. AC input of the power supply (switched full range - 90 to 265 Vac).
25. Flat cable input of the power supply.
26. Radio connector (future use).
18
Attention: the AMT 8000 alarm center does not have an auxiliary output to feed other devices and no connection point
must be used on the alarm center cards (alarm center, GPRS card, telephone line card or source) for this functionality,
because besides damaging the alarm center, it may damage the devices due to the alarm center operating at different
voltages according to the circuit.
4.1. Power supply for the alarm center (full range 90 and 265 Vac)
Alarm unit is equipped with a full range switching source that works with the input voltage of 90 and 265 Vac without the
need of a voltage selector switch. This way, even if some voltage variation occurs in the mains, the alarm unit will continue
working normally (as long as the voltage is in the range of 90 to 265 Vac).
On this board there are two protection fuses of the unit. If you need to change, use new ones of the same value (250
V/400 mA).
To connect the AC mains input and also to ground, it is recommended to use a three pin cable with a gauge of 1 mm or
higher.
The output to the alarm center board is 5.7 Vdc and 1.7 A.
CN3
Q1 Q2
R3
R5
C7
JP1
CN3
TERRA
TERRA
CN2
CL2
TR1
D1
R4
UR1
CN1
TE
OK
U1
12
L3
L1
FONE
LINHA
108XXXX
XFT8000
4640511/0/8P
TRIGON 1721a
YEE19V-9P2.03MHA
Terra
Rede AC
Fusíveis
Conector bateria
Conector para a central
Ground
Fuses
AC Mains
Connector for the alarm
center
Battery connector
XFT 8000 Power Supply
Connect the source ground terminal as shown above to the local electrical installation ground.
If the local electrical installation is not grounded, install a grounding bar and wire the connection terminal to the alarm
center to perform the correct grounding.
Attention: it is mandatory to connect the grounding to the alarm center in order to have greater protection against
lightning and overload by the mains and/or telephone line. If this connection is not made, the alarm center will function
normally, but will be unprotected against overloads.
Warranty does not cover possible damages caused by lightning to the alarm center or to any other equipment connected
to it.
4.2. Battery
AMT 8000 alarm center has an internal rechargeable battery of 3.7 Vdc and a capacity of 3,000 mA. The battery connector
is located on the power supply board and is used to connect the battery to the alarm system. To wire the battery to this
connector use the cable that comes with it, as shown below.
TERRA
TERRA
CN2
CL2
CN3
Q1 Q2
R3
R5
C7
JP1
CN3
TR1
D1
R4
UR1
CN1
TE
OK
U1
12
L3
L1
FONE
LINHA
108XXXX
XFT8000
4640511/0/8P
TRIGON 1721a
YEE19V-9P2.03MHA
Rechargeable battery for AMT 8000 alarm center
19
Alarm center has protection against reverse polarity and short circuit in the battery.
The unit also has protection to prevent the battery from being damaged in the event of a mains failure.
If the voltage in the battery is below 2.8 V, the alarm center will switch off in order not to damage the battery.
Battery life of 8 hours with Wi-Fi enabled and 16 hours with Wi-Fi disabled.
Attention: in case battery replacement is required, please contact our accredited service network.
4.3. XAG 8000 GPRS Module
Check that the cable for connection to the alarm center is correctly connected, passing under the board of the FXO
8000 telephone line module (if used), and its installation should be done only with the unit off, to avoid damage to the
equipment and the installer.
In the XAG 8000 module there are two slots to be allocated two chips (SIM card) being superimposed on each other, with
chip 1 being above chip 2. When installing the chips, let the metal contacts of the same face down and insert until the end
of the slot for the correct allocation of chips.
2
1
CHIP
CHIP 1CHIP 2
Chip allocation in XAG 8000 GPRS module
4.4. FXO 8000 Phone Module
Check that the cable for connection to the alarm center is correctly connected, and that it is only installed with the unit off,
to avoid damage to the equipment and the installer.
In the FXO 8000 module there is the
Line
terminal, where the main telephone line (two wires) must be wired, connecting
the
Phone
output (two wires) in the other telephone sets contained in this same line and as can be seen in the image
below:
Line
Phone
Wiring diagram of telephone line in the FXO 8000 module
This connection is necessary so that in case of reporting events or remote accesses, the alarm center is not without
communication or has it interrupted if other phones of the same circuit enter/are in operation. In this case, when reporting
events or remote access, the other phones will be inoperative, because the center will be occupying the line.
4.5. AMT 8000 Alarm Center
AMT 8000 alarm center has a tamper key against violation, and if this tamper switch is opened/violated, registered
sirens will trigger and send the corresponding event if the
Problems that generate trigger
function is enabled (see section
Problems that generate trigger
).
Ethernet cables, AC power and telephone line should be directed through the hole located at the rear of the alarm center.
20
Alarm center can be installed on several surfaces, always placing it in a vertical position with a height between 1.80 and
2.20 meters and using double-sided tape or screws (not included) to x the base and after securing the alarm center,
tting and checking that it has been placed correctly so that there are no falls and damage, and directing the wires in the
dedicated areas.
5. Operation
Once the installation is nished, connect the alarm center to the local mains and the rechargeable battery.
Note:
to connect the AMT 8000 alarm center it is necessary that it is connected to the AC mains and the 5-way cable of
the source is wired to the
Source
connector of the alarm center board, otherwise the alarm center will not power on even if
the same is with battery. With the alarm center on and the battery connected, it will be recharged by the source and when
the AC network is dropped the alarm center will be maintained by battery power.
5.1. Description of the XAT 8000 LCD keyboard indications
The following icons are located on top of the LCD display:
» : If this icon is ashing, it indicates that a trouble has been detected.
» : it will light up whenever there is a shot in the siren
.
» P: with the icon lit, the center is in programming mode.
» Battery: indicates the battery status of the alarm center.
5.2. Display of troubles
The occurrence of troubles is described as follows:
On the XAT 8000 keyboard the icon will ash.
If any trouble is detected, press the up or down arrow keys on the XAT 8000 keyboard to view them. To end the display,
press the
Exit
key.
Note:
if the
Indication of troubles by the siren in the activation/deactivation
function and
Beeping of the siren in the
activation/deactivation
are enabled and if any trouble is detected, 1 long beep will beep on activation and 2 long beeps
on deactivation.
5.3. Description of the LEDs signaling on the alarm center boards
LEDs of alarm center baseplate
LED Status/event Signaling1
LED1/LED2 Disconnected from the Ethernet network LED off
LED1/LED2 Connected to Ethernet network1Flashing LED
LED3 Center off LED off
LED3 Center on Flashing LED
LED3 Center on and registering devices LED lit
1
This status does not mean that the system is connected to the monitoring servers. To view the connection status, observe through the
Menu
function (see section
Connections).
LEDs of XAG 8000 GPRS board
LED Status/event Signaling1
LED1, LED2 Powered (connected to CPU board) LED1 and LED2 constantly on
LED1, LED2 Chip (SIM1 or SIM2) seeking
connection Only the corresponding LED is lit
LED1 Chip 1 (SIM1) connected to servers LED ashing 1 time (connected to server 1),
LED ashing 2 times (connected to server 2)
LED2 Chip 2 (SIM2) connected to servers LED ashing 1 time (connected to server 1),
LED ashing 2 times (connected to server 2)
1
This status does not mean that the system is connected to the monitoring servers. To view the connection status, observe through the
Menu
function (see section
Connections).
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126