LGU+ IoT@home SSE-304 User manual

Type
User manual
When Light ON, LED off
When Light OFF, LED On.
Z- Wave Add / Remove*
Add / Remove by the button in the bottom (3rd Button)
Press the 3rd button for above 5 seconds,
- Then, red color LED blinks every 0.5 second 6 times.
- At this time released the button during the red color LED
blinking.
- Then, ZWAVE Add / Remove operation is started.
- Over 30 seconds, Add / Remove mode is stopped.
When keep pressing buttons after 5 seconds,
- Red LED is blinking times after 10 seconds.
- At his time, released the button, and initialized.
- When initialized, whole adding information erased.
- All lights OFF. Button LED all ON.
Product Reset Instructions
(* Use this procedure only when the network primary
controller is missing or otherwise inoperable.)
1) Hold the low touch button for 10 seconds.
- Keep holding the button, then at 5 second, red LED of
3rd
button is blinking 6 times and keep holding10 seconds
later, red LED of 3rd is blinking 6 times again. In this time
factory reset will be started if you release the button.
2) After factory reset is done, all the lamps will be turned off
and all variables will be initialized to default values.
*“Add” means “Add” the device into the Z-Wave network
*”Remove” means “Remove” the device from the Z-Wave
network.
Product Overview & Specification
U+ Switch enables Light ON/OFF remotely with
PUSH buttons and wireless connection
(Z-Wave※①).
Functions
1. Light ON/OFF (PUSH button, Wireless connection)
2. Current capacity : Light power consumption standard
1 Contact
2 Contact
3 Contact
1 switch
30W~600W
X
X
2 switch
30W~600W
~600W
X
3 switch
30W~600W
~600W
~600W
Product figuration and each name
Z-Wave : Wireless communications protocol with
low-power and low-bandwidth, such as home
automation and sensor network
1st Button : Light connected to 1st light
2nd Button : Light connected to 2nd light
3rd Button : Light connected to point 3rd light
Wiring connect socket
∙ Jack to connect the wiring of light switch
∙ Terminal sequence
[Front] [Rear]
1st(L1) : Line connect terminal to Light #1
2nd(L2) : Line connect terminal to Light #2
3rd(L3) : Line connect terminal to Light #3
COM(L): Common line connectors
2 “COM” Connected inside SET
Wiring
1st
Light
2nd
Light
3rd
Light
Buttons and LED/Light action
Precautions
Please read the instructions/setup manual before
construction/wiring work/operation/repair/check.
Danger : When mishandled, danger of mortality
risks or serious injury.
Caution : When mishandled, possibility of slight
injury or property damage.
Danger
(1) Before installing the product, be sure to shut
circuit breaker OFF to cut off the power.
Danger of electric shock during install.
(2) Be sure to attach barrier to the part of power
side. If not, danger of short accident.
(3) Be sure not to contact exposed terminal.
Cause of short-circuit and electric shock.
(4) If the circuit breaker operated automatic shut-
off , please be sure to remove the cause before
turning on the power. Electric shock or fire may
occur.
Cautions
(1)Be sure to read this instructions before product
install, and follow instruction when installing..
(2) There is a risk of malfunctions and accidents
caused by improper installation. Installation and
maintenance of the circuit breaker should be done
by a qualified person .
(3)Avoid circumstances including rainwateroil
dust sunlight, etc.. Danger of electric shock, short
circuit, fire, malfunctions.
(4) Connect to a power source in accordance with
the rated power of the product. If not, may cause a
unit malfunction and failure.
(5) Because the operating current is changed
according to the mounting angle of the product,
install the product and the wall is to be
perpendicular to the ground
(6)Be sure not to drop and break the product
during handling and installation
(7) Damage or dismantle caused by user
carelessness would not be guaranteed.
(8) For detailed information, you may refer to the
catalogue or visit our website at www.ezex.co.kr
or contact our representative contact number.
1st
(L1)
2nd
(L2)
3rd
(L3)
COM
(L)
COM
(L)
AC
220V
ZWAVE supplementary Information
Group ID
Maximum Nodes
Description
1
5
Z-Wave Plus Lifeline
2
5
Button 1 Switch On/Off Notification
3
5
Button 2 Switch On/Off Notification
4
5
Button 3 Switch On/Off Notification
Following is the product's Association Group information
Association Command Class supports 4 groups.
- Group ID 1 is for Z-Wave Plus Lifeline
- Group ID 2/3/4 are used for reporting On/Off Notification.
- Maximum nodes in each group is 5.
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers
and/or other applications by applying the inclusion method explained above.
All non-battery operated nodes including this product within the network will act as repeaters regardless of vendor to increase
reliability of the network.
Security
- Unauthenticated S2 Security
* Security (S2) enabled Z-Wave controller must be used to fully utilize the product.
Multi Channel Command Class
- Multi Channel CC is used to control light (from Controller) and report light status to controller
- Controlling light from Controller
. Used MULTI_CHANNEL_CMD_ENCAP command
. Destination endpoint (1, 2 and 3) is mapped to 3 light buttons.
. Control light using BASIC_SET command of BASIC CC.
- Reporting light status to Controller
. Used MULTI_CHANNEL_CMD_ENCAP command
. Destination endpoint (1, 2 and 3) is mapped to 3 light buttons
. Used notification command class.
. Used NOTIFICATION_REPORT command to report light status.
Notification Command Class
- Notification CC is used to report light status to controller when controlling the light at once.
- (Unsolicited) Reporting light status to Controller
. Used NOTIFICATION_REPORT command
. Notification type is 0x08 (Power Management)
. All light is on, then “Event” value is 0x03. All is off, then “Event” value is 0x02.
ZWAVE supplementary Information
Configuration Command Class
Command Classes
- Non-Security CC
COMMAND_CLASS_ZWAVEPLUS_INFO
COMMAND_CLASS_SUPERVISION
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC
COMMAND_CLASS_VERSION
COMMAND_CLASS_SECURITY_2
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
-S2 Security CC
COMMAND_CLASS_SWITCH_BINARY
COMMAND_CLASS_ASSOCIATION
COMMAND_CLASS_NOTIFICATION
COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V2,
COMMAND_CLASS_MULTI_CHANNEL_V3
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_SENSOR_MULTILEVEL
COMMAND_CLASS_POWERLEVEL
Parameter
Number
Size
Default Value
Description
0
1
0x00 (fixed)
Default value (No effect to system)
1
2
0x258
(600)
Temperature/Humidity Reporting period
2
1
0x14
(20)
Temperature Deviation
3
1
0x0A
(10)
Humidity Deviation
Operation of Configuration CC based on LGU+ Software specification.
- The value for parameter number 0 is 0x00 as default.
- If setting values are out of range (when setting these values by using CONFIGURARION_SET command), setting values are ignored.
(CONFIGURARION_SET command is valid if input parameters meet above condition.)
  • Page 1 1
  • Page 2 2
  • Page 3 3

LGU+ IoT@home SSE-304 User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI