CAME PST003 Installation guide

Type
Installation guide

This manual is also suitable for

PST001
TWISTER SERIES
TRIPOD
TURNSTILE
English
EN
INSTALLATION MANUAL
119G3040EN
WARNING!
Important instructions for the safety of people:
READ CAREFULLY!
Foreword
• Use of the products must be restricted to its intended use
(i.e. that for which it was expressly built for). Any other use is
to be considered dangerous. Came Cancelli Automatici S.p.A.
is not liable for any damage resulting from improper, wrongful
or unreasonable use Keep these warnings with the installa-
tion and use manuals issued with the automated system.
Before installing
(preliminary check: in case of a negative
outcome, do not proceed before having
complied with the safety obligations)
• Make sure that the parts you intend to automate are in
good working order, and that they are properly balanced
and aligned. Also, make sure that proper mechanical stops
are already in place • If the operator will be installed at a
height of less than 2.5 m from the ground or other access
level, check whether you will need any protections and/or
warnings • Any gate leaves, fi tted with pedestrian entrances,
onto which you will install an operator, must have a blocking
mechanism when the gate is in motion • Make sure that the
opening of the automated gate is not an entrapment hazard
as regards any surrounding fi xed parts • Do not mount the
operator upside down or onto any elements that may fold
under its weight. If needed, add suitable reinforcements at
the points where it is secured • Do not install onto gates on
either an upward or downward slope (i.e. that are not on fl at,
level ground) • Check that any lawn watering devices will not
wet the gearmotor from the bottom up.
Installation
• Carefully section off the entire site to prevent unauthorised
access, especially by minors and children • Be careful when
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling
safety equipment • All opening commands (e.g. buttons, key
selectors, magnetic detectors, etc.) must be installed at least
1.85 m from the gate’s area of operation perimeter - or where
they cannot be reached from the outside of the gate. Also,
the direct commands (e.g. push button, or proximity devices,
etc.) must be installed at a height of at least 1.5 m and must
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release
mechanism • Before delivering to the client, verify that the
system is EN 12453 (impact test) standard compliant. Make
sure that the operator has been properly adjusted and that the
safety and protection devices, as well as the manual release
are working properly • Where necessary and in plain sight,
apply the Warning Sings (e.g. gate plate).
Special instructions and
advice for users
• Keep the gate’s area of operation clean and clear of any
obstacles. Trim any vegetation that may interfere with the
photocells • Do not allow children to play with the fi xed com-
mand devices, or in the gates area of operation. Keep any
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether
any anomalies or signs of wear and tear appear on the moving
parts, on the component parts, on the securing points, on the
cables and any accessible connections. Keep any joints (i.e.
hinges) lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on
photocells and sensitive edges, every six months. Keep glass
panels constantly clean (use a slightly water-moistened cloth;
do not use solvents or any other chemical products) • If the
system requires repairs or modifi cations, release the operator
and do not use it until safety conditions have been restored
• Cut off the power supply before releasing the operator for
manual openings. See instructions • Users are FORBIDDEN
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL
ASSISTANCE STAFF • On the periodic maintenance log, note
down the checks you have done.
Special instructions and
advice for all
• Avoid working near the hinges or moving mechanical parts
• Stay clear of the gate’s area of operation when in motion •
Do not resist the direction of movement of the gate; this may
present a safety hazard • At all times be extremely careful
about dangerous points that must be indicated by proper
pictograms and/or black and yellow stripes • When using
a selector or command in ‘maintained action’ mode, keep
checking that there are no people in the area of operation of
the moving parts. Do this until you release the command •
The gate may move at any time without warning • Always cut
the power when cleaning performing maintenance.
THIS PAGE LEFT INTENTIONALLY BLANK
THIS PAGE LEFT INTENTIONALLY BLANK
#

#
Pag.
2
- Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
4.1 Turnstile
4 Description
2.1 Intended use
1 Legend of symbols
This symbol shows parts to be read carefully.
This symbol shows parts related to safety.
This symbol shows what to tell users.
The TWISTER electromechanical turnstile is designed to select transit flows in high-volume passage areas, and in highly fre-
quented contexts like stadiums, airports, stations, public buildings and in any other places where high-volume flows need to be
regulated and/or selected
Any installation or use other than that shown in this manual is prohibited.
3 Reference Legislation
IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION
WARNING: WRONG INSTALLATION MAY CAUSE SERIOUS INJURY, FOLLOW ALL INSTALLATION INSTRUCTIONS
THIS MANUAL IS EXCLUSIVELY MEANT FOR PROFESSIONAL INSTALLERS OR OTHER COMPETENT PERSONS
This product is designed and built by CAME Cancelli Automatici S.p.A. in compliance with the current safety legislation.
It allows passage in the desired direction of one person a time. By activating a command device, the mechanism releases the tripod
which rotates freely allowing people to pass through; the arms automatically return into place and the mechanism locks immediately
after a single passage, waiting for a new command.
The range includes:
001PST001 - Bi-directional electromechanical tripod turnstile AISI 304 steel with scotch-brite fi nishing, complete with ocntrol board,
transponder sensors and high-luminosity LED bi-directional traffi c light with display. Tripod automatic release in case of blackout.
Power: 230 V AC 50 / 60 Hz
Power Draw: 260 mA max
Insulation class: II
Protection rating: IP44
Weight: 60 Kg
The product being described herein complies with the following legislation: see compliance statement.
4.2 Technical Data
2 Intended use and limits
11
1
7
5
2
1
6
5
8
9
4
4
8
3
10
12
13
14
1200
950
750
250
195
ø 40
850
Pag.
3
-
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
4.4 Dimensions
4.3 Description of parts
Legs1.
Tripod2.
Steel body3.
Casing4.
Casing cover5.
Upper cover6.
Traffic-light with display7.
Transponder8.
Status display9.
Mechanism10.
Control panel11.
Cover lock12.
Screws and washers for fixing the legs13.
Screws for fixing the casing14.
EXIT
SWIMMING POOL
Pag.
4
- Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Standard installation Against the wall installation
Multiple installation
Platform installation
5 Application examples
Warning: Turnstile-controlled exits cannot serve as emergency exits. Always have an emergency exit and one also for disabled
persons.
6 Installation
Only skilled, qualified staff must perform the installation, in full compliance of the current legislation.
6.1 Preliminary checks
Before installing the automated device, please:
• Set up a proper omnipolar cut-off device, with contacts more than 3 mm apart, and power source isolation;
• Set up proper tubing and conduits for the electrical cables to go through with enough protection from any mechanical damage;
Check that any connections within the container (made to give continuity to the protection circuit) have additional isolation
compared to the other internal power conductors.
Make sure you have all the tools and materials needed to carry out the installation in total safety and in compliance with current
legislation. The figures shows examples of installers’ tools.
6.2 Tools and equipment
Suggested distance
between turnstiles
SWIMMING POOL
2
1
3
4
4
5
6
Pag.
5
-
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
6.3 Standar installation
6.4 Setting up the turnstile
Warning: installation required two people. Use hoisting equipment to move and position the turnstile.
Do not lean on the turnstile until it is solidly anchored, to prevent it from toppling over.
1) Used the issued key to open the lock on the front part of the
turnstile.
Tripod turnstile1.
Traffi c-light with display2.
Electric wiring connector block3.
Transponder for transit access4.
Protection handrail5.
Status displays6.
2)
Raise the cover carefully so as to gently remove the
metal strip from the display (traffic light).
1
2
1
2
Pag.
6
- Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
4) Remove the top cover.
Note: Lift the cover slightly tor easy removal.
5) Remove the two screws that fix the casing to the legs.
6) Remove the protective casings by gently lifting them. Then,
extract the casings.
6) Use the supplied M10 x 60 screws and flat washer to secure
the three arms to the tripod hub.
7) Slide the tripod onto the pin that protrudes out of the body,
secure it using the screw cap and M8 x 20 screw.
200
870
ø11
ø40
10
0
Ø12 mm
Ø12 mm
Pag.
7
-
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
5) Insert the nogs into the holes.
6) Place the turnstile over the nogs and pass the cable duct
through the central hole.
Screw the turnstile to the ground using the ratchet spanner.
6.5 Preparing the site and fixing the turnstile to the ground.
1) Check that the floor where the turnstile is anchored is level
and without warping.
3) Drill the marked holes.
2) Depending on the size of the passage, decide where to
install the turnstile and any accessories that should be added,
marking the fixing holes with a pencil respecting the measure-
ments given in the drawing.
4) Set up corrugated tubes for cables to go through.
If the ground cannot be drilled use a platform (001PSPEBUL) for
fixing the turnstile and accessories.
L
N
+ E
-
EbA EbA EbI EbI
10
S2
S12EM432111
Pag.
8
- Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
7 Electric cabling
Use the proper cable clamps to secure
the cables inside the box in the control
panel.
Threading the power supply (and that
of any accessories) cable through the
bottom plate of the turnstile leg.
Pass the cable through the hole in the
top of the turnstile leg.
Threading the power supply cable (al-
ternatively to the hole on the base plate)
through a cable gland at the bottom of
the turnstile leg.
Earth
Cable clamps
Hole
Hole
7.1 Cable types and sections
N.B. If the cable length differs to that shown in the table, determine cable section based on the actual power draw by the connected
devices and according to what is prescribed by law CEI EN 60304-1.
For sequential connections on the same line, length-measurements by the table must be converted on the basis of draw and actual
distances. To connect any products not mentioned in this manual, see documentation provided with said products.
Cable clamps
Connections Cable types
Cable length
1 < 10 m
Cable length
10 < 20 m
Cable length
20 < 30 m
Power to electrical panel 230 V
FROR CEI 20-22
CEI EN
50267-2-1
3G x 1,5 mm
2
3G x 1,5 mm
2
3G x 1,5 mm
2
Power to accessories 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1 mm
2
Command and safety devices 2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
L
N
+ -
+ E
-
A B
GND
EbA EbA EbI EbI
10
S2
S12EM432111
6
7
8
9
15
14
3
2
2
4
5
11
10
12
13
1
16
Pag.
9
-
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
FUSE TABLE
To protect: Fuse rating:
Control board (line) 1,6A-F
Accessoriesi 1,6A-F
8.2 Main Components
Transformer1.
Transformer connection terminals2.
1.6A accessories Fuse3.
Endpoint connection terminal4.
1.6A line fuse5.
230 V AC control board power terminals6.
Terminals for connecting accessories and com-7.
mand systems.
electro-block connection terminal board8.
Not used terminal board 9.
Transponder connection terminals10.
R700 board connectors11.
Memory roll board connectors12.
Traffic-light display connection terminal13.
Functions programming buttons14.
RBM84 connection terminal15.
Signal LED16.
The control panel is powered by 230 V AC on terminals L-N, with
max frequency of 50/60Hz
The 24 V power supply is of the SELV type.
The command and control devices and accessories are 24 V D.C.
Warning! The accessories must not comprehensively exceed
35W.
All connections are quick-fuse protected, see table.
The functions and user interface are set and displayed on the
software-managed display.
8.1 General description
8 Control panel
The defi nable command and control functionalities are:
- clock-wise activation;
- counter clock-wise activation;
- Stop command;
- emergency command.
WARNING: before doing any work inside the equipment, cut the
power mains.
10 11 1 2 3 4 EM 2 S1 S2
A
B
GND
A
B
GND
L
N
Pag.
10
10 - Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Counter-clockwise activating button / (N.O. contact)
Release the tripod in an anti-clockwise direction. If
no other command is given, the turnstile relocks itself
automatically after the time set in the “F5” function.
Clockwise activating button / (N.O. contact)
Release the tripod in a clockwise direction. If no
other command is given, the turnstile relocks it self
automatically after the time set in the “F5” function.
RBM84 - Access control
Software for recording user movements and for managing
personalised permits according to the program given to
each single user.
9 Electrical connections
230 V AC power, 50/60Hz
frequency
Connect the earth to the terminal fi tted on the turnstile.
9.1 Power
9.2 Optional devices
Panic button / (N.C. contact)
Activating the contact triggers total block of the
turnstile. Note: Short circuit if unused!
Emergency button / (N.C. contact)
Pressing the button allows the tripod to turn in both
directions.
Note: Short circuit if unused!
Terminals for powering 24 V AC accessories,
max 250 mA and 35 W
+
E
-
L1T
L2T
24V
0V
EbA EbA
EbI EbI
L
N
+ -
+ E
-
A B
GND
EbA EbA EbI EbI
10
S2
S1 2 EM 4 3 2 1 11
Pag.
11
11 -
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Endpoint
Clockwise activated trasponder / (N.O. contact)
Release the tripod in a clockwise direction. If no other com-
mand is given, the turnstile relocks itself automatically after
the time set in the “F5” function.
Counter- clockwise activated trasponder / (N.O. contact)
Release the tripod in an anti-clockwise direction. If no other
command is given, the turnstile relocks itself automatically
after the time set in the “F5” function.
Blue
White
Pink
Red
Electromagnet
Red
Red
Red
Red
S1 - Red
GND - Black
Status displays
TSP00
White
Brown
Green
Transformer
9.3 Already connected devices
Traffi c-light with display
#!.#%,,)!54/-!4)#)
#!.#%,,)!54/-!4)#)
1
2
1
2
Pag.
12
12 - Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Decoder boards for
transponders
LThe R700 boardscommand the turnstile with (TZP00/LT001) proximity sensors and the memory roll to save and load any settings
including registered users on another board
The R700 and Memory Roll boards must be inserted when the power is disconnected.
9.5 Decoder boards
Once the power is connected, wait 10 seconds before proceeding with any operations
Memory roll
9.6 Fixing the side casings and cover
1) Remount the side casing following the procedure given at point
6 on page 5 in reverse order.
2) Introduce the casings and screw them in place.
3) Introduce the top cover and connect the strap to the traffic
light.
IMPORTANT: before proceding with programming, make sure the electric cables are out of the way of the mechanical
parts.
{
{
{
{
{
< 00:00 >
F - 1
F - 2
F - 3
F - 4
F - 5
F - 6
F - 7
F - 8
F - 17
F - 16
F - 15
F - 14
F - 13
F - 12
F - 11
F - 10
F - 9
TSP2
TSP1
12 :30
Pag.
13
13 -
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
The ENTER button is for:
-entering the menu
-confirming or memorising the set value
The ESC button is for:
-exiting the menu
-cancelling the settings
Transponder to insert, modify and confirm functions via the Master card
without having to open the turnstile.
Position the Master card near the transponder receiver and carry out the
settings required which will be displayed step-by-step on the display.
10 Programming
10.1 Description of commands
The <> buttons are for:
- moving among menu items;
- increasing or decreasing a setting
Display to view the functions and settings that are assigned
via programming buttons or transponder
10.2 Menu structure
Creating the MASTER card
Creating a new card
Cancelling a card
Cancelling all of the cards
Inserting timeout time
Chosing the information-type on display
Cancelling the number of passages
Setting the number of passages
Setting the time and date
Data reading in the memory roll
Data recording in the memory roll
Differential entrance management
Antipassback mode (On or Off)
Setting the entrance direction
Periferal device number
Standalone or online mode
Enabling the Intrusion Buzzer
N.B. Functions F-2, F-3 and F-4 appear on the display only when the MASTER pass is generated.
Transponder used to
confirm the functions
and settings (ENTER)
Transponder used to
change, increase and
decrease a value (< >)
The functions can be programmed from the internal keypad on the control panel or from the Master pass.
Warning: to use the programming function, both display and transponder commands must be installed on the turnstile.
Also, all NC contacts, if unused, must be shortcircuited.
F - 1
F
-
2
---
F
-
1
F
-
2
F - 3
F
-
4
500
CLR-A
F - 4
F
-
5
F - 5
F
-
6
OFF
65000
F - 6
F
-
7
10:00
F - 3
1
3
2
500
1
3
2
500
CLR
10
12
11
60
F
-
2
F
-
3
F
-
4
F
-
5
Pag.
14
14 - Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
10.3 Functions menu
Function 1: Creating the MASTER card
Creating the MASTER, activates the programming functions without opening the small-door.
See detailed function on pages 14 and 15.o.
Function 2: Creating a new card
Creating new cards (max. 500 cards)
See detailed fucntions on page 16.
Function 3: Cancelling a card.
Select the number of the pass that has to be cancelled using the keys or place the pass on the transponder (TSP1), the display
will show the pass number. Press ENTER to confirm cancellation.
Function 4: Cancelling all cards.
Cancelling all the cards memorised in the software.
Function 5: Setting the timeout time.
To set the time that the turnstile stays released after a button or transponder command (2-3 / 2-4).
The waiting time can be set between 10” and 60”.
Function 6: Chosing the type of information on the display.
Chosing the type of information to view on the display between the number of passages, the time or neither
Max 500 users
F - 10
-
65000
F - 7
F
-
8
CLR
OFF
F - 8
F
-
9
02
01
65000
12:00
2008
OFF
02
01
60
F - 11
F
-
12
OFF
ON
F - 12
F
-
13
1
3
2
60
:00 12:
31
07
12
Sto
ON
F - 9
F
-
10
F
-
9
F -
6
F
-
7
F
-
10
-
F
-
8
Pag.
15
15 -
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Function: Cancelling the number of passages
Cancelling the number of passages (entrance-exit) made by the turnstile
Function 8: Setting the maximum number of passages.
Setting the number of maximum passages allowed in the direction established by the “F-13” function.
From 1 to 65,000 passages or leave unlimited passages “OFF”.
Note: the number appearing on the display shows user presence at the entrance at that moment.
Function 9: setting the time and date.
Note: press the ENTER button until the datum you wish to change appears then press the <> buttons to increase or decrease the
datum, press ENTER until the automatic setting choice for daylight savings time (ON) or only set the GMT (OFF) time for the entire
year, confirm by pressing ENTER again.
Function 10: intrusion alarm Buzzer
Activating the buzzer in case of intrusion of deactivation. The activation time can be set between 1” and 60”.
Function 11: StandAlone or Online mode.
Stand-Alone (the turnstile works automatically – OFF) or On-Line (the turnstile is connected to and managed by the RBM84
access control system – ON).
Function 12: Periferal device number.
Assign to each turnstile (if more than one) a peripheral number (e.g. access control, etc.)
minutes
Hour
Days of the week, e.g.: 1 =
Monday, 2 = Tuesday, etc.
Day of the monthMonthyear
< ---
--- >
F - 14
F
-
115
F - 13
F
-
14
< OFF >
< ON >
000
F
-
16
F - 17
000
OFF
< -2- >
< -6- >
< -5- >
< -4- >
< -3- >
F - 15
F
-
16
< -1- >
F
-
13
F
-
12
F
-
14
F - 17
F-17
F - 16
F
-
15
Pag.
16
16 - Manual code:
119G3040
119 G3 04 0 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
Function 13: Setting the direction for the passage counter.
Assign to the turnstile the direction for which the counter records the entrances set by function “F-8”. The flashing arrow indicated
the direction.
Function 14: Antipassback mode.
Activate or deactivate the Antipassback functions.
Prevents entering an area when the person is already inside. It can be used to prevent using the same pass for two or more conse-
cutive accesses to the same area: for example in a gym, to prevent clients entering with the personal pass of a client who is already
inside.
Funzione 16: Data recording in the memory roll.
It saves registered users and data settings in the memory roll.
Funzione 17: Data reading in the memory roll.
It loads registered users and data settings in the memory roll.
Intermittent arrow
Function 15: Differentiated passage mamangement.
Free = free passage for all users (Green Arrow).
Blocked = passage not allowed to all users (Red Arrow)
Controlled = passage allowed only to cleared users (Green Intermittent Arrow).
OFF = passaggio consentito solo a utenti abilitati su entrambe le direzioni (Freccie ros-
se).
Attention: when one of these 6 functions is activated, the antipassback function (Function 14)
and the maximum number of transits (Function 8) are deactivated.
12 :30
OFF Controlled Controlled
-1- Free Blocked
-2- Blocked Free
-3- Controlled Blocked
-4- Blocked Controlled
-5- Controlled Free
-6- Free Controlled
12 :30.
X2
F - 1
F - 1
F - 2
OFF
F - 8
01
02
Sto
Clr
Pag.
17
17 -
Manual code
:
119G3040
119G3040 ver.
1.5
1.5 09/2010
© CAME cancelli automatici s.p.a. -
The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
10.5 Creating a master card
1) Press ENTER twice consecutively.
IMPORTANT: before actually creating the card, carefully read the instructions.
Follow the order of the following instructions otherwise the programming will not work.
To enter the functions menu, press
the ENTER button.
To choose the function, press
the arrows…
then press ENTER
then press ENTER to
confirm
also for the the “sub-
menus”, move by using the
arrows … to raise or lower
a value.
Open the turnstile’s upper cover
and position it turned by 90° abo-
ve the body, so that the display
can be easily read. Open the
electrical oanel box to use the
programming buttons.
10.4 Browsing and programming the menu via the internal button console.
IMPORTANT: before doing any programming, carefully read the instructions.
Follow the order of the following instructions otherwise the programming will not work
to modify increments, settings, creating cards, after confir-
ming with ENTER, “Sto” appears on the display.
to cancel cards, number of passages, after confirming
with ENTER, “Clr” appears on the dislay.
Note: the flashing dot on the display shows that the Master
pass has not been generated yet.
----
Sto
F - 1
F - 1
F - 2
TSP1
TSP2
TSP1
TSP2
TSP1
TSP2
TSP1
TSP2
Pag.
18
18 - Manual code:
119G3040
119G3040 ver.
1.5
1.5 09/2010 © CAME cancelli automatici s.p.a. - The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s.p.a. to notify users.
ENGLISH
2) the “S1” LED transponder flashes RED and the lines will appear on the display.
3) Within 10 seconds, approach a the chosen MASTER card to the flashing transponder and leave it for several seconds until the
display shows the “Sto” (Storage) letters.
Intermittent Red LED
10.6 Browsing and programming the menu using the Master card.
1) To enter the function menu, place the Master pass on the transponder (TSP1). The display will show “F1.
The transponder remains green throughout the programming time. Carrying out this operation is like keeping the “ENTER” button
pressed.
2)By moving the Master card, alternatively either right or left, or vice-versa, allows you to set the various functions without ope-
ning the turnstile.
Sensor used to confirm functions and
settings (ENTER)
Warning: always first create the MASTER card and keep it to be able to browse the functions menu.
Note: if the MASTER card is misplaced, follow the same procedure from point 1 using a new card.
red LED
red LED
green LED
Transponder (TSP2) used to change, increase or
decrease a value (endless loop system).
Intermittent Red LED
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24

CAME PST003 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI