CAME STILE ONE Installation guide

Type
Installation guide
INSTALLATION MANUAL
STILE ONE
TRIPOD
TURNSTILES
FA00151-EN
English
EN
Page
2
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
CAUTION!
important personal safety instructions:
READ CAREFULLY!
DANGER OF HAND CRUSHING
DANGER - LIVE PARTS
FOREWORD
• THIS PRODUCT SHOULD ONLY BE USED FOR THE PURPOSE FOR WHICH IT WAS
EXPLICITLY DESIGNED. ANY OTHER USE IS CONSIDERED DANGEROUS. CAME S.P.A.
IS NOT LIABLE FOR DAMAGE CAUSED BY IMPROPER, INCORRECT OR UNREASONABLE
USE. • THE SAFETY OF THE PRODUCT, AND THEREFORE ITS PROPER INSTALLATION,
DEPENDS ON TOTAL COMPLIANCE WITH THE TECHNICAL SPECIFICATIONS AND INSTALLA-
TION PROCEDURES, AS WELL AS WITH RULES REGARDING SAFETY AND USE, EXPRESSLY
MENTIONED IN THE TECHNICAL DOCUMENTATION FOR THE PRODUCTS THEMSELVES. •
KEEP THESE WARNINGS TOGETHER WITH THE INSTALLATION AND OPERATION MANUALS
FOR THE OPERATOR SYSTEM COMPONENTS.
BEFORE INSTALLING
(PRELIMINARY CHECK: IN CASE OF A NEGATIVE OUTCOME,
DO NOT PROCEED UNTIL YOU HAVE COMPLIED
WITH THE SAFETY REQUIREMENTS)
• INSTALLATION AND TESTING MUST ONLY BE PERFORMED BY QUALIFIED PERSONNEL
CABLE ROUTING, INSTALLATION, CONNECTION AND TESTING MUST BE CARRIED OUT TO
THE HIGHEST STANDARDS OF WORKMANSHIP AND IN ACCORDANCE WITH APPLICABLE
STANDARDS AND LAWS • BEFORE STARTING ANY OPERATION, YOU MUST READ ALL
THE INSTRUCTIONS; INCORRECT INSTALLATION MAY BE DANGEROUS AND INJURE AND
DAMAGE PEOPLE AND THINGS • CHECK THAT THE OPERATOR IS IN GOOD MECHANICAL
CONDITION, THAT IT IS BALANCED AND ALIGNED, AND THAT IT OPENS AND CLOSES
CORRECTLY. IF NEEDED, ALSO INSTALL SUITABLE GUARDS OR USE APPROPRIATE ADDI-
TIONAL SAFETY SENSORS • ENSURE THAT OPENING THE TURNSTILE DOES NOT CREATE
A DANGEROUS SITUATION • DO NOT MOUNT THE OPERATOR UPSIDE DOWN OR ONTO
ANY ELEMENTS THAT MAY FOLD UNDER ITS WEIGHT. IF NEEDED, ADD SUITABLE REIN-
FORCEMENTS AT THE POINTS WHERE IT IS SECURED • DO NOT INSTALL ON GROUND
THAT IS NOT LEVEL • CHECK THAT ANY LAWN WATERING DEVICES WILL NOT WET THE
OPERATOR FROM THE BOTTOM UP.
INSTALLATION
• CAREFULLY SECTION OFF THE ENTIRE SITE TO PREVENT UNAUTHORISED ACCESS,
ESPECIALLY BY MINORS AND CHILDREN • BE CAREFUL WHEN HANDLING OPERATORS
THAT WEIGH MORE THAN 25 KG. IN SUCH CASES, USE PROPER WEIGHT HANDLING
SAFETY EQUIPMENT • CE SAFETY DEVICES MUST BE INSTALLED IN COMPLIANCE WITH
APPLICABLE LEGISLATION AND ACCORDING TO THE HIGHEST STANDARDS OF WORKMAN-
SHIP, BEARING IN MIND THE ENVIRONMENT, THE TYPE OF SERVICE REQUIRED AND THE
OPERATING FORCES APPLIED TO THE MOVING TURNSTILES. POINTS WHERE THERE IS
A RISK OF CRUSHING, SHEARING OR DRAGGING MUST BE PROTECTED • END USERS
MUST BE INFORMED OF ANY RESIDUAL RISKS BY MEANS OF SPECIAL PICTOGRAMS AS
ENVISAGED BY LEGISLATION • ALL OPENING COMMANDS (BUTTONS, KEY SELECTORS,
MAGNETIC READERS ETC.) MUST BE INSTALLED AT LEAST 1.85 M FROM THE PERIM-
ETER OF THE AREA OF TURNSTILE MOVEMENT, OR WHERE THEY CANNOT BE REACHED
FROM OUTSIDE THROUGH THE TURNSTILE. IN ADDITION, THE DIRECT COMMANDS (BUT-
TON, TOUCH ETC.) MUST BE INSTALLED AT A MINIMUM HEIGHT OF 1.5 M AND MUST
NOT BE ACCESSIBLE TO THE PUBLIC • THE TURNSTILE MUST CLEARLY SHOW THE
IDENTIFICATION DATA • BEFORE CONNECTING THE TURNSTILE TO THE POWER SUP-
PLY, MAKE SURE THAT THE IDENTIFICATION DATA MATCHES THE MAINS DATA • THE
TURNSTILE MUST BE CONNECTED TO AN EFFECTIVE EARTHING SYSTEM COMPLIANT WITH
APPLICABLE STANDARDS • THE MANUFACTURER IS NOT LIABLE FOR THE USE OF NON-
ORIGINAL PRODUCTS; THIS VOIDS THE WARRANTY • BEFORE DELIVERY TO THE USER,
CHECK THAT THE SYSTEM COMPLIES WITH THE EN12453 AND EN12445 STAND-
ARDS, ENSURING THAT THE OPERATOR HAS BEEN ADEQUATELY ADJUSTED AND THAT
THE SAFETY AND PROTECTION DEVICES ARE WORKING CORRECTLY • AFFIX WARNING
SYMBOLS CLEARLY WHERE NECESSARY IN A CLEARLY VISIBLE POSITION.
SPECIAL INSTRUCTIONS AND
ADVICE FOR USERS
• KEEP THE TURNSTILES AREA OF OPERATION CLEAN AND CLEAR OF ANY OBSTA-
CLES. CHECK THAT THE PHOTOCELLS' AREA OF OPERATION IS FREE FROM OBSTACLES
• CHILDREN MUST BE SUPERVISED TO MAKE SURE THEY DO NOT PLAY WITH THE
OPERATOR AND THE FIXED CONTROL DEVICES OR STAND IN THE TURNSTILE'S AREA OF
OPERATION. KEEP THE REMOTE CONTROL DEVICES (TRANSMITTERS) OR ANY OTHER
CONTROL DEVICE OUT OF REACH OF CHILDREN, TO PREVENT THE OPERATOR BEING
ACTIVATED INVOLUNTARILY. • THE OPERATOR CAN BE USED BY CHILDREN AGED OVER
8 AND BY PERSONS WITH REDUCED PHYSICAL, SENSORIAL OR MENTAL ABILITIES, OR
BY PERSONS WITH NO EXPERIENCE OR WITHOUT THE AWARENESS NEEDED, AS LONG
AS THEY ARE SUPERVISED BY OR HAVE RECEIVED INSTRUCTIONS REGARDING SAFE
USE OF THE OPERATOR AND UNDERSTAND THE RELATED DANGERS. CLEANING AND
MAINTENANCE MEANT TO BE PERFORMED BY THE USER MUST NOT BE PERFORMED BY
UNSUPERVISED CHILDREN. • CHECK THE SYSTEM FREQUENTLY TO SEE WHETHER ANY
ANOMALIES OR SIGNS OF WEAR AND TEAR APPEAR ON THE MOVING PARTS, ON THE
OPERATOR COMPONENTS, ON THE SECURING POINTS AND DEVICES, ON THE CABLES
OR ON ANY ACCESSIBLE CONNECTIONS. KEEP ANY JOINTS LUBRICATED AND CLEAN,
AND DO THE SAME WHERE FRICTION MAY OCCUR • PERFORM FUNCTIONAL TESTS ON
PHOTOCELLS EVERY SIX MONTHS. ENSURE THAT THE GLASS ON THE PHOTOCELLS IS
KEPT CLEAN (USE A CLOTH SLIGHTLY MOISTENED WITH WATER; DO NOT USE SOLVENTS
OR ANY OTHER CHEMICALS AS THESE COULD DAMAGE THE DEVICES) • IF THE SYSTEM
REQUIRES REPAIRS OR MODIFICATIONS, DISCONNECT THE POWER TO THE OPERATOR
AND DO NOT USE IT UNTIL SAFETY CONDITIONS HAVE BEEN RESTORED • CUT OFF THE
ELECTRICAL POWER SUPPLY FOR MANUAL OPENING. READ THE INSTRUCTIONS • IF
THE POWER CABLE IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER OR
THE TECHNICAL ASSISTANCE SERVICE OR BY A PERSON WITH A SIMILAR QUALIFICATION
SO AS TO PREVENT ANY RISKS • IT IS STRICTLY FORBIDDEN FOR USERS TO PERFORM
OPERATIONS THEY ARE NOT EXPLICITLY REQUIRED AND ASKED TO DO. FOR REPAIRS,
ADJUSTMENTS AND EXTRAORDINARY MAINTENANCE, CONTACT THE SPECIALIST TECHNI-
CAL SERVICE CENTRE • ON THE PERIODIC MAINTENANCE LOG, NOTE DOWN THE
CHECKS YOU HAVE DONE.
FURTHER SPECIAL INSTRUCTIONS
AND ADVICE FOR ALL
• AVOID WORKING NEAR THE TURNSTILES OR MOVING MECHANICAL PARTS • STAY
CLEAR OF THE TURNSTILE'S AREA OF OPERATION WHEN IN MOTION • DO NOT RE-
SIST THE DIRECTION OF MOVEMENT OF THE OPERATOR; THIS MAY PRESENT A SAFETY
HAZARD • AT ALL TIMES BE EXTREMELY CAREFUL ABOUT DANGEROUS POINTS THAT
MUST BE INDICATED BY PROPER PICTOGRAMS AND/OR BLACK AND YELLOW STRIPES
WHEN USING A SELECTOR OR COMMAND INHOLD-TO-RUNMODE, KEEP CHECKING
THAT THERE ARE NO PEOPLE IN THE AREA OF OPERATION OF THE MOVING PARTS. DO
THIS UNTIL YOU RELEASE THE COMMAND • THE TURNSTILE MAY MOVE AT ANY TIME
WITHOUT WARNING • ALWAYS CUT THE POWER WHEN CLEANING OR PERFORMING
MAINTENANCE.
= 770
= 998
= 792
= 265
= 307
= 440
= 322
= 805
= 326
= 100
= 320
Page
3
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
DESCRIPTION
Two-way motorised turnstile, made from grey painted textured steel complete with control board. In the event of a blackout, the tripod is free to move in both
directions. Arms made from AISI 304 steel with gloss fi nish.
Programming and control fully managed from access control system remotely via CRP.
The motorised turnstile is two-way and selective, allowing only one person at a time to pass through in the chosen direction. After receiving a command, the
tripod turns slightly to encourage the person to pass through; as soon as it detects a push from a user, it completes the rotation and then repositions itself waiting
for a new command. It is also possible to select free rotation and blocked mode.
Break-in system: any attempt to force the turnstile is detected by the encoder and sets o the buzzer.
Arm drop system: in emergency situations, in the event of a power cut, the horizontal arm moves down, freeing the passage.
The range includes:
001PSMM01 - Standard suspended tripod turnstile
001PSMM02 - Suspended tripod turnstile with arm drop
Optional accessories:
001PSMMA-A - Indicator LED bars
001PSMMA-B - Wall fi xing bracket
001PSMMA-C - Boxed single-leg
001PSMMA-D - Tubular single-leg
Used for access selection and authorisation in areas with high transit intensity such as tradefair grounds, stadiums, sports centres, parking facilities, shopping
centres, undergrounds, public o ces.
This symbol indicates parts to read carefully.
This symbol indicates parts about safety.
This symbol tells you what to say to end users.
Measurements, unless otherwise indicated, are in millimetres.
KEY
Intended use
Dimensions
Page
4
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Technical data
Model PSMM01 PSMM02
Protection rating (IP) 44
Power supply (V - 50/60 Hz) 120/230 AC
Rated power (W) 120
Power in standby mode (W) 410
Max transits/minute* 30
Insulation class I
Weight (kg) 22 25
Operating temperature (°C) -20 to +55
* Detectable in Free access mode (see F 77 function). In Controlled mode, the times vary according to the access control reading speed.
Description of the components
1. Box
2. Tripod
3. Upper cover
4. Cover lock
5. Mechanism
6. Indicator LED bar housing
7. Control panel
Preliminary checks
Tools and materials
Before starting installation:
if necessary, prepare the corrugated pipes to pass the electric cables through;
provide a suitable single-pole disconnection device, with a maximum of 3 mm between the contacts and an overvoltage category of at least 3, to disconnect
the power supply;
prepare suitable piping and ducts for routing the electrical cables, ensuring protection against mechanical damage;
make sure that any connections within the container (made to ensure the continuity of the protection circuit) are fitted with additional insulation compared
to the other internal conductor parts;
Make sure you have all the tools and materials you will need for the
installation at hand to work in total safety and compliance with current
standards and regulations. The figure shows some examples of installer’s
tools.
GENERAL INSTALLATION INSTRUCTIONS
Installation must be carried out by qualified and experienced personnel in compliance with applicable regulations.
1
3
4
2
Page
5
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Example of a system
Examples of use
1. Single-leg turnstile
2. Emergency button
3. Barrier
4. Junction box
Cable type and minimum cross-section
Connection cable length
< 20 m 20 < 30 m
Gearmotor with control board 3G x 1.5 mm² 3G x 1.5 mm²
Control devices 2 x 0.5 mm² 2 x 0.5 mm²
Safety devices 2 x 0.5 mm² 2 x 0.5 mm²
24 V accessories 2 x 0.5 mm² 2 x 0.5 mm²
With 230 V power supply and outdoor use, use H05RN-F cables compliant with 60245 IEC 57 (IEC); for indoor use, on the other hand, use H05VV-F
cables compliant with 60227 IEC 53 (IEC). For power supplies up to 48 V, FROR cables 20-22 II cables compliant with EN 50267-2-1 can be used.
For CRP connection, use UTP CAT5 cables up to 1000 m.
If the cables differ in length compared to what is shown in the table, the cable cross-section is determined according to the actual current draw of the
devices connected and according to the provisions of the EN 60204-1 standard.
For connections that require several loads on the same line (sequential), the sizes given on the table must be re-evaluated based on actual current draw
and distances. When connecting products that are not specified in this manual, please refer to the documentation provided with said products.
= 270
= 100
= 746
= 250
= 70
Page
6
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Opening the turnstile
Release the upper cover via the lock ; lift it up from the front and pull it forwards to remove it.
After determining the position, draw axes as shown and mark them with a pencil.
Drill holes at the marked points and insert screw anchors.
We recommend the use bolts suitable for the type of wall/floor; the holes on the structure are Ø 9.
DRILLING FOR SECURING TO THE FLOOR
WITH LEG
DRILLING FOR SECURING TO THE WALL
Marking for securing the turnstile
INSTALLATION
The following illustrations are only examples, given that the space for securing the operator and accessories varies depending on the overall dimensions. The
installation technician is responsible for choosing the most suitable solution.
Pay particular attention to the verticality of the wall or the flatness of the floor on which the turnstile is secured.
The location in which to secure the turnstile depends on the size of the opening and any accessories to be connected.
If the turnstile is installed close to a wall, leave at least 5 cm on the opposite side in relation to the tripod.
The turnstile must be assembled by two people. To transport and lift it, use proper lifting equipment.
Risk of tipping over or falling! Do not lean on the turnstile until it is fully secured.
The height from the ground is nominal
and can be varied as desired.
With the PSMMA-B fi xing bracket, with the same
nal height of the turnstile from the ground, this
height must be increased by 3 cm.
PSMMA-B
Page
7
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Wall-mounting
Loosen the 4 screws and remove the power and
control unit to access the box fixing wall.
Move the bolts on the bottom of the box, one at
a time.
Without a bracket, secure the turnstile using appropriate bolts to the type of wall , also using the cross bars as reinforcement.
With the PSMMA-B fixing bracket, use the nuts and washers provided
Insert the connecting cables through the appropriate cable glands.
Replace the power and control unit in the box.
Page
8
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Floor installation
Secure the tubular or boxed single leg to the floor using appropriate bolts (not provided).
Route the cables inside the single leg and, through the relative cable glands, inside the body of the turnstile .
Assemble and secure the body of the turnstile to the single leg using the bolts provided .
Page
9
- Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
In the standard version with fixed tripod arms, they must be immobilised with the following procedure:
Remove the 3 ABS covers . Arm the tripod by opening the arms then attach the fixing bracket by turning it.
Secure the brackets using the M4x8 screws .
Remove any vertical play with the bolt and side play by firmly tightening the bolt .
Replace the covers using all the 3.9x16 screws
Secure the tripod to the rotation mechanism using the M8x20 screws and the washers ; finally close using the small cover and the M4x25 screw
Preparing the tripod (for PSMM01 only)
Securing the tripod
1
6
5
13
12
11
10
16
14
15
4
17
3
2
9
8
7
Page
10
10 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
WIRING AND PROGRAMMING
Before intervening on the control board, disconnect the line voltage.
Control board power supply (V - 50/60 Hz): 120 - 230 AC.
Control device power supply: 24 V DC.
The output 24 V DC power supply is SELV and so there is no risk of electrocution.
All the connections are protected by quick fuses.
Main components
1. Programming buttons
2. Terminal block for operation counter or external siren
3. Memory roll card connector
4. R700 card connector of the first control device
5. R700 card connector of the second control device
6. Display
7. Terminal block for control devices or paired connection
8. Connector for arm rotation sensor
9. Connector for indicator LED bar
10. Terminal block for transponder
11. Terminal block for control devices
12. Accessory power supply terminal block
13. Board power supply terminal block
14. Accessory fuse
15. Board fuse
16. Motor/encoder connector
17. Power indicator LED
18. Line fuse
FUSE TABLE
Line fuse 1.6 A-F (230 V)
2 A-F (120 V)
Accessory fuse 1 A-F
Control unit fuse 630 mA-F
A B GND
24V 0V10 11
Page
11
11 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Power supply
Indicator devices
Terminals for powering
the accessories at 24 V AC.
Overall power
permitted: 10 W
24 V AC
power supply
Mains
power supply*
Transformer
Base card
Line
fuse holder
Optional item PSSMA-A.
Turnstile status indicator LED bars.
Confi gured for 230 V power supply.
With 120 V mains power supply, invert cables and and
change the line fuse .
Control devices
RBM84 - Access control.
Connection to the Came access
control system.
CRP - Came Remote Protocol.
Connect to Came home
automation systems.
EMC filter
120 V 230 V
24V 0V10 11
CANCELLI AUTOMATICI
R700
TSP00
LT001
R700
Memory Roll
Page
12
12 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Stop button (N.C. contact).
Turnstile stop button with exclusion of the automatic closing cycle. To
resume movement, activate a control device.
N.B. if the contact is not used, select 0 (Disabled) using the F 1
function.
Contact (NO) for anti-clockwise rotation activation devices.
For details see function F 54.
Contact (NO) for clockwise rotation activation devices.
For details see function F 54.
Input (NO) on the fi rst SENSOR 1 control device (transponder or card reader with R700 card) for
clockwise rotation.
Input (NO) on the second SENSOR 2 control device (transponder or card reader with R700 card) for
anti-clockwise rotation.
Contact (NC) for release devices.
When activated, in PSMM01 it allows free rotation in both directions; in
PSMM02 it causes the arms to drop.
Control devices
The R700 decoding cards are used to control the turnstile with the sensors (TSP00/LT001), the to save and load all settings including registered
users in another card.
Before you connect them you MUST cut off the mains voltage and, if present, disconnect the batteries.
Other connections
Black
Red
Black
Red
24 V DC gearmotor
with encoder
Gearmotor with encoder
FERRITE
Page
13
13 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
F 1 Total Stop
F 2 2-CX Input
F 2 2-CY Input
F 19 Invitation Time
F 28 Rotation Speed
F 30 Slowdown Speed
F 31 Bracing Power
F 32 Invitation Rotation Speed
F 33 Calibration Speed
F 34 Motor Torque Adjustment
F 36 Invitation Angle
F 37 Slowdown Space
F 49 Management
F 50 Data Saving
F 51 Data Reading
F 53 AntiPassBack
F 54 Entry Direction
F 55 Break-In Alert Angle
F 56 Device number
F 57 Close Limit Switch Offset
F 63 COM Port Speed
F 73 Obstacle Detection Time
F 74 Turnstile Reset Time
F 76 Relay Operating Mode
F 77 Turnstile Operating Mode
U 1 Storing User
U 2 Deleting User
U 3 Deleting All Users
A 2 Motor Test
A 3 Run Calibration
A 4 Reset Parameters
A 5 Operation Counter
H 1 Firmware Version
Function Description (
default values in negative
)
F-1 Total Stop. With button connected to terminals 1-2.
[ ] To disable it (mandatory if there is no button); [ ] to enable it.
F-2 Setup 2-CX Input. Choice of the function activated by the connected device.
[ ] To disable it; [ ] for the arm drop function.
F-3 Setup 2-CY Input. Choice of the function activated by the connected device.
[ ] To disable it; [ ] for the cover lock key function.
F-19 Invitation Time. Wait time after pre-rotation (F 36), after which the turnstile goes back and is ready for a new command.
[ ] To disable it; [ …… ] adjustment from 1 to 30 seconds.
F-28 Rotation Speed. Set as a percentage.
[ …… …… ] Adjustment from 50% to 100% of motor speed.
F-30 Slowdown Speed Set as a percentage.
[ …… …… ] Adjustment from 15% to 40% of motor speed.
PROGRAMMING
Description of programming commands
Menu mapping
Menu description
Start programming by first performing the A 2 Motor test and A 3 Run calibration functions.
The key is used to
enter programming mode
enter the individual menus
confirm/store the set value
The keys are used to
move from one menu heading to another
increase or decrease a value
The key is used to exit the menus without saving changes
Display to show the functions
and settings that are assigned
via the programming keys.
After 10 seconds without
pressing a key, the individual
programs end without effects,
similar to the key.
Page
14
14 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Function Description (
default values in negative
)
F-31 Bracing Power. Setting the force that opposes the turnstile in the event of forcing.
[ …… …… ] Adjustment from 20% to 50% of the motor power.
F-32 Invitation Rotation Speed Setting the speed during invitation pre-rotation, calculated as a percentage.
[ …… …… ] Adjustment from 15% to 30% of motor speed.
F-33 Calibration Speed. Setting the speed during the calibration operations, calculated as a percentage.
[ …… …… ] Adjustment from 15% to 30% of motor speed.
F-34 Motor Torque Adjustment Force applied to the turnstile during normal access.
[ …… …… ] from minimum to maximum.
F-36 Invitation Angle. Initial pre-rotation of the turnstile after an opening command.
[ …… …… ] Angle adjustment from 5 to 30 degrees.
F-37 Slowdown Space. Setting the slowdown run, calculated as a percentage.
[ …… …… ] Adjustment from 25 to 45% of the total rotation run.
F-49 Management. Setting the turnstile management mode.
[ ] Stand Alone Management; [ ] RBM84 access control management; [ ] management via CRP (Came Remote Protocol).
F-50 Data Saving. Saving of registered users and all settings in the .
The function only appears with connected.
[ ] To disable it; [ ] to enable it.
F-51 Data Reading. Loading all the data from the .
The function only appears with connected.
[ ] To disable it; [ ] to enable it.
F-53 Antipassback. To prevent one card being used for two or more consecutive accesses in the same area.
[ ] To disable it; [ ] to enable it.
F-54 Entry Direction. To conform rotation to the direction of entry of the opening.
[ ] For anti-clockwise tripod
rotation [ ] For clockwise tripod rotation
F-55 Break-In Alert Angle Angle of forced rotation, beyond which the turnstile alerts a break-in.
[ …… ] Angle adjustment from 1 to 30 degrees ( = disabled).
F-56 Device Number. If the turnstile is operated by the RBM84 access control (see F-49), it is useful to assign each one a unique number.
[ …… ] Maximum number of turnstiles permitted 255.
F-57 Limit Switch Offset. See details in “Limit Switch Offset” chapter.
From -10° [ ] to no adjustment [ ] to +10° [ ].
F-63 COM Port Speed. Setting the communication speed of the COM serial port, measured in Baud.
[ ] 1200; [ ] 2400; [ ] 4800; [ ] 9600; [ ] 14400; [ ] 19200; [ ] 38400; [ ] 57600; [ ] 115200;
F-73 Obstacle Detection Time Push time after which an obstacle is considered to be present.
[ …… …… ] Adjustment from 1 to 10 seconds.
F-74 Turnstile Reset Time To reset normal turnstile operation after an obstacle has been detected.
[ …… …… ] Adjustment from 1 to 15 seconds.
F-76 Relay Operating Mode To choose between the counter functions for turnstile operations (relay 1 = anti-clockwise rotation; relay 2 = clock-
wise rotation) or for the activation of an external device. In both cases, with or without simultaneous activation of the break-in buzzer.
[ ] Operation counter + Buzzer enabled; [ ] Operation counter + Buzzer disabled.
[ ] Device on C-NO1 enabled + Buzzer enabled; ] Device on C-NO1 enabled + Buzzer disabled.
F-77 Turnstile Operating Mode Setting the activity status for each direction of the traffic.
Selection IN (entry) OUT (exit)
KEY:
Controlled = transit only permitted to
authorised users (green LED on steady);
Free = free transit to all (LED bar
flashing green);
Blocked = no transit for anyone (LED
bar on steady red).
* with PSMM-A accessory assembled
[ ]Blocked Blocked
[ ] Blocked Controlled
[ ]Controlled Blocked
[ ] Controlled Controlled
[ ] Blocked Free
[ ]Free Blocked
[ ]Free Controlled
[ ]Controlled Free
[ ] Free Free
U-1 User Storage. Up to 150 users. See details in “Entering a user” chapter.
U-2 User Deletion. See details in “Deleting a user” chapter.
ENTER ENTER >
3A 0 1 LCA
°°
°
°°
°
Page
15
15 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Function Description (
default values in negative
)
U-3 Deleting All Users Deleting all stored users. After deletion, the message [ ] appears.
[ ] To disable it; [ ] to delete all users.
A-2 Motor Test Test to check for correct tripod rotation.
[ ] To disable it; [ ] to enable it.
A-3 Run Calibration See details in “Run calibration” chapter.
[ ] To disable it; [ ] to enable it.
A-4 Reset Parameters. Deletion of all programming (including the run calibration) and return to the default parameters.
[ ] To disable it; [ ] to reset all the default parameters.
A-5 Operation Counter. This enables you to view the number of operations performed or forcing attempts.
[ ] For forcings; [ ] for operations.
H-1 Firmware Version. Shows the firmware version. For example [ ]
Activate procedure A 3.
The card will make the tripod perform a complete 360° calibration rotation, recording the 3 stop positions of
the arms.
Before calibrating the run, check that the manoeuvre area is free from any obstacle.
During calibration, all safety devices will be disabled except for the Total Stop device.
Run calibration
Definitions
At the end, the display will indicate registration in progress for a few
seconds with these screens and then automatically exit the procedure.
ROTATION
INVITATION
ANGLE
SLOWDOWN
SPACE
CLOCKWISE ROTATION
ANTI-CLOCKWISE ROTATION
…… ……
CL
LCr
I
U
I
U
i
i
i
i
i
i
2
U
3
U
2
U
3
U
2
2
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
>
>
>
0
0
0
2
>
ENTER > ENTER <
5
i 5
- i
75F
Page
16
16 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
User storage (max. 150)
Deleting a single user
Deleting all users
Activate procedure U 1 and select 1 to activate user storage.
Activate procedure U 2 and select 1 to activate user deletion.
Activate procedure U 3.
The first free position for storage will appear flashing*: pass the card or cards in front of the transponder sensor; the number of the last card will remain lit for a
few moments to register the users. At the end, the next free number will flash.
At the end of the manual, there is a table in which to list users for easier management.
* When adding/deleting users, the numbers displayed fl ashing are numbers that are available and can be used for users to be added.
Use the arrow keys to move to the user to delete and press Enter: the wording CLr will flash for a few seconds and the procedure will terminate automatically.
For another deletion, repeat the procedure.
To delete all the users, use function U 3 (see menu detail).
Select 1 and press Enter to delete all stored users at the same time: the wording CLr will flash for a few seconds and the procedure will terminate automatically.
Activate procedure F 57.
Press > or < to adjust the arm stop position by 15° more or less (to compensate any flooring or fixings that
are not perfectly horizontal).
Limit switch offset
After the run calibration, the limit switch o set operation further adjusts the rotation of the arms on the perpendicular, as illustrated.
Page
17
17 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
MAINTENANCE
Before any maintenance, disconnect power to prevent any dangerous situations that may be caused by accidental movement .
For correct maintenance of the AISI 304 steel (tripod arms), refer to the section about cleaning steel in the 119RW48 manual.
Table of the mean number of cycles between failures (MCBF) for StileOne turnstiles, considering correct installation and maintenance as described in this
manual:
Model Operating limits MCBF
001PSMM01
001PSMM02
Maximum number of cycles per day: continuous service
Maximum number of cycles per minute: 30 (1 cycle every 2 seconds) 3,000,000
Troubleshooting
PROBLEM POSSIBLE CAUSES CHECKS AND SOLUTIONS
The turnstile does not accept commands • No power
Stop button open
Check for mains power
Check that the button is intact/suitable
Periodic maintenance
Every 1,000,000 cycles and in any case every 6 months:
Check the tightness of the bolts
Check the tightness of the tripod head bolts
Check the efficiency of the arm drop
Once electrical connection and commissioning have been completed, connect the earthing cable supplied attached to point to the cover in the point indicated, using
the bolts supplied .
If fitted with the boxed leg, assemble the closing plate .
FINAL OPERATIONS
Page
18
18 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
Error messages and warnings during installation
ERROR CAUSE SOLUTIONS
E 1 Calibration aborted Repeat calibration
E 2 Incorrect calibration Repeat calibration
E 3 Encoder broken Replace the encoder
E 7 Run time expired Check the operation of the gearmotor
E 8 Hatch open Close the cover
E 9 Obstacle during the return from the opening rotation
(see function F-36)
Remove the obstacle
E 10 Obstacle during the opening rotation Remove the obstacle
E 20 Arm dropped Reset the arm
Indications of the indicator LED bar
Individual LED status Description
• FREE entry
• CONTROLLED entry
• BLOCKED entry
Calibration in progress
Stop button activated
FREE entry with ongoing error
CONTROLLED entry with ongoing error
BLOCKED entry with ongoing error
Ongoing error during calibration
Key:
Steady red - Flashing red - Quick flashing red
Steady green - Flashing green
DISMANTLING AND DISPOSAL
CAME S.p.A. implements an EN ISO 14001 certified and compliant Environmental Management System at its plants, to ensure environmental protection.
Please continue our efforts to protect the environment, something that CAME considers to be one of the foundations in developing its business and market
strategies, simply by observing brief recommendations as regards disposal:
DISPOSAL OF PACKAGING
Packaging components (cardboard, plastic etc.) can be disposed of together with normal household waste without any difficulty, by simply separating the
different types of waste and recycling them.
Before proceeding, it is always advisable to check specific regulations in force in the place of installation.
DISPOSE OF PROPERLY!
DISPOSAL OF THE PRODUCT
Our products are made with different materials. Most of them (aluminium, plastic, iron, electrical cables) can be disposed of together with normal household
waste. They can be recycled if collected, sorted and sent to authorised centres.
Other components (control boards, transmitter batteries etc.) on the other hand, may contain pollutants. They should therefore be removed and handed over to
companies authorised to recover and recycle them.
Before proceeding, it is always advisable to check specific regulations in force in the place of disposal.
DISPOSE OF PROPERLY!
REGULATORY REFERENCES
The product complies with the applicable reference directives.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
Page
19
19 - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © CAME S.p.a. - The data and information provided in this manual are subject to change at any time without prior notice.
LIST OF REGISTERED USERS
www.came.com
www.came.com
CAME S.p.A.
CAME S.p.A.
Via Martiri Della Libertà, 15 Via Cornia, 1/b - 1/c
31030
Dosson di Casier
Dosson di Casier
Treviso
Treviso
- Italy
33079 Sesto al Reghena
Sesto al Reghena
Pordenone
Pordenone
- Italy
(+39) 0422 4940
(+39) 0422 4941
(+39) 0434 698111
(+39) 0434 698434
English
English - Manual code:
FA00151-EN
FA00151-EN - ver.
2
- 08/2016 - © Came S.p.A.
The data and information provided in this manual are subject to change at any time without prior notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

CAME STILE ONE Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI