Cooper Lighting Sure-Lites GFR User manual

Type
User manual

This manual is also suitable for

Catalog #
Project
Comments
Prepared by
Type
Date
SPECIFICATION FEATURES
05/19/2008 2:56:13 PM
Consult your representative for additional options and finishes.
ADX081164
ORDERING INFORMATION
GFR
Electrical
- 6V or 12V DC Input Voltage
GFR
Construction
- Matches RG1 Series emergency
lighting units
- 20-gauge die-stamped steel
housing with white baked
enamel finish
- Housing adjusts in plaster frame
1 3/8" to accommodate different
ceiling thicknes
- Bar hangers included for fast,
easy installation
- Gimbal trim ring has white paint
finish
- Lamp adjusts 40° from vertical
with 358° rotation
GFR
Code Compliance
- CSA Certified
- UL Listed
- UL Damp Location Listed
- Life Safety NFPA 101
GFR
Warranty
- Unit: 1-year
GFR
Lamp Data
- 6 Volt Incandescent Sealed Beam
- 12 Volt Incandescent Sealed
Beam
- Consult factory for other lamp
types (See Technical Information
Section)
GFR SERIES
ROUND SPECIALTY
REMOTES
CSA Certified
Emergency Lighting
E N E R G Y D AT A
Power Consumption is equal
to lamp wattage.
G F R S e r i e s
Isofootcandle
.oN margaiD.oN pmaLsttaWstloVepyT pmaLhsiniF.oN golataC
GFR2703 White Trim Incandescent Sealed Beam 6 8 029-03 3
GFR2716 White Trim Halogen Sealed Beam 12 8 029-16 6
Alternate Lamps: Consult Cooper Lighting Representative
Other Finishes Available: Cooper Lighting Representative
COOPER LIGHTING - SURE-LITES
®
Sure-Lites • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801
05/19/2008 2:56:13 PM
ADX081164
PHOTOMETRICS
SERIES
GFR
LAMP
AXIS
10
FEET
LEFT
FEET
RIGHT
10
0 10 20 30 40 50 60
FEET FROM LAMP (Measured on axis)
1F
C 0.5 0.3 0.2 0.1
70
0
LAMP
AXIS
10
FEET
LEFT
FEET
RIGHT
10
0 10 20 30 40 50 60
FEET FROM LAMP (Measured on axis)
1F
C 0.5 0.3 0.2 0.1
70
0
H o r i z o n t a l D i s t r i b u t i o n
Ve r t i c a l D i s t r i b u t i o n
Diagram No. 3 Lamp No. 029-03 @ 108 Initial Lumens
LAMP
AXIS
10
FEET
LEFT
FEET
RIGHT
15
0 10 20 30 40 50 60
FEET FROM LAMP (Measured on axis)
70
0
1FC
0.5 0.3 0.2 0.1
LAMP
AXIS
10
FEET
LEFT
FEET
RIGHT
15
0 10 20 30 40 50 60
FEET FROM LAMP (Measured on axis)
70
0
1FC
0.5 0.3 0.2 0.1
Diagram No. 12 Lamp No. 029-121 @ 75 Initial Lumens
Diagram No. 3
Lamp No. 029-03
Diagram No. 12 Lamp No. 029-121
0 20 50 100
15
FEET
LEFT
FEET
RIGHT
15
FEET FROM LAMP (Measured on axis)
10 4030 90807060
0.
5 0.3
0.2
0.1
1FC
LAMP
AXIS
0
0 20 50 100
15
FEET
LEFT
FEET
RIGHT
15
FEET FROM LAMP (Measured on axis)
10 4030 90807060
0.
5 0.3 0.2 0.1
1FC
0
LAMP
AXIS
Diagram No. 6 Lamp No. 029-16 @ 155 Initial Lumens
Diagram No. 6
Lamp No. 029-16
  • Page 1 1