EPO10

Geotab EPO10 Installation guide

  • Hello! I've analyzed the Field Services Installer Documentation for IOX-WRKS and EPO10. This document explains how to connect the IOX-WRKS to the Rasco EPO10 controller, set up the required controller parameters, including the proper protocol, passcode and baud rate, and use the SIM mode to test the device speed. All related to a specific telemetry input mappings for various types of plows. I'm ready to answer your questions regarding the installation and use of these devices.
  • What cable is used to connect IOX-WRKS to Rasco EPO10?
    What protocol does Rasco EPO 10 require?
    What is the passcode to access the Rasco menu?
    What should be the baud rate?
    How do you enter SIM mode?
Rasco EPO10 + IOX-WRKS
Field Services Installer Documentation:
IOX-WRKS
Notice: Always use winter input mapping for telemetries
AUX5- Belly Plow or Manual Spreader, AUX6- Front Plow, AUX7- Wing Plow, AUX8- Tow Plow or Beacon
Rasco EPO10 to IOX-WRKS Primary port
IOX-WRKS primary port connects to
the serial port on the Rasco EPO10
with a standard straight cable
HRN-DB9SI15
Required Controller settings
Rasco EPO 10 requires protocol EN 15430-1
Rotate center dial to the right to obtain “Rasco” selection
Press “check” button, enter passcode ( 727) using the three dials, press checkmark again.
Select the menu button, then Executive settings, Option settings, then Mobile box.
Ensure baud rate is set to 115200
Exit to main operator screen
Press “test” to enter SIM mode, use up/down arrows to increase / decrease speed.
Confirm data flow using MyGeotab or calling support.
Exit SIM mode when complete.
/