SINGLE-STAGE COMPRESSOR DESIGN AND EFFICIENCY PROVEN IN THE
MOST DEMANDING APPLICATIONS
Designed to be the most reliable chillers we’ve ever made, YORK centrifugal chillers
incorporate a single-stage compressor design. With fewer moving parts and straightfor-
ward, efficient engineering, YORK single-stage compressors have proven durability re-
cords in hospitals, chemical plants, gas processing plants, the U.S. Navy, and in other
applications where minimal downtime is a crucial concern.
In thousands of installations worldwide, YORK single-stage compressors are working to
reduce energy costs. High strength aluminum-alloy compressor impellers feature back-
ward curved vanes for high efficiency. Airfoil shaped pre-rotation vanes minimize flow dis-
ruption for the most efficient part load performance. Precisely positioned and tightly fitted,
they allow the compressor to unload smoothly from 100% to minimum load for excellent
operation in air conditioning applications.
PRECISION CONTROL OF COMPRESSOR OIL PRESSURE
Utilizing our expertise in variable speed drive technology and applications, Johnson Con-
trols has moved beyond the fixed head and bypass approach of oil pressure control. The
old approach only assured oil pressure at the outlet of the pump, rather than at the com-
pressor, and allows no adjustment during chiller operation. YK-EP chillers feature two (2)
variable speed oil pumps (VSOPs), one for each compressor, to monitor and provide the
right amount of oil flow to the compressors on a continuous basis. This design also pro-
vides sophisticated electronic monitoring and protection of the oil pump electrical supply,
ensuring long life and reliable operation of the oil pump motor. Variable speed drive tech-
nology reduces oil pump power consumption, running only at the speed required, rather
than at full head with a pressure regulating bypass valve.
FACTORY PACKAGING REDUCES FIELD LABOR COSTS
YORK YK-EP centrifugal chillers are designed to keep installation costs low. YK-EP chill-
ers can be shipped using Form 2, Form 3, or Form 7 shipment methods.
Form 2 shipment allows the chiller to be shipped completely packaged as one assem-
bly and saves on installation time. Form 3 shipment requires the two drive lines to ship
separate from the shells as three major assemblies. Form 7 shipment, for more complex
installations, ensures the two drivelines, evaporator, and condenser shells are split apart
into four major assemblies.
In all three shipping methods, refrigerant and oil charges are shipped separately, con-
nections are closed/flanged, wiring connections are simple plug-type to ensure simple
commissioning using a starter, and heat exchanger refrigerant sides are charged with
nitrogen.
TAKE ADVANTAGE OF COLDER COOLING TOWER WATER TEMPERATURES
YORK YK-EP centrifugal chillers have been designed to take full advantage of colder
cooling tower water temperatures, which are naturally available during most operating
hours. Considerable energy savings are available by letting tower water temperature
drop, rather than artificially holding it above 75°F (23.9°C), especially at full load and full
condenser flow, as some chillers require. 50°F (10°C) is used as the rule of thumb in many
scenarios depending on the conditions, but this Min. ECWT should be validated using the
formula on page 51.
Introduction (Cont'd)
YK-EP chillers feature
two (2) variable speed
oil pumps (VSOPs),
one for each com-
pressor, to monitor
and provide the right
amount of oil flow to
each compressor on a
continuous basis.