Clean Dump CDPU Installation guide

Type
Installation guide
Installation manual
Step #1
Locate the house battery on RV and disconnect power. using part( C )the 10 ga wire and part( L)
battery connectors make a good secure connection to battery cables and run wire back to
macerator mounting location at black and gray water sewer outlet
Step #2
Install part (D) in line 20 amp fuse
in positive side of 10 ga wire at an
easily accessible location if fuse
needs to be checked in future.
Note: (the fuse should be placed
between the battery and the
macerator) See wiring diagram
Step #3
Install Part B 20 amp switch at
desired location. Note: (this should be close to macerator ) Negative wire will run from ground
side of battery to one pole on switch and then using Part(K) 6 ft piece of 10 ga single wire to
ground side of macerator. Note: you will make part (K) from the 20ft piece of 10ga wire
supplied.( Safety) : do not have macerator powered while completing installation. See wiring
diagram
Step #4
Install Part (A) Flo-Jet macerator in compartment with sewer outlet for motor homes and under
frame for travel trailer and fifth wheel applications. When installing macerator be aware
material from sewer outlet must be able to flow to pump with gravity feed. Level or a slope to
macerator is fine do not mount macerator above outlet. There is 4 screws supplied with
macerator to accomplish this.
Step #5
Install Part (N) the 2ft piece of 3” flexible connection hose using part (J) heavy duty hose clamp
at the macerator and part (O) the white coil filler material and part (P) 3” clamp on part (F) the
45 degree clear connector that hooks to sewer outlet. Note: Make sure and get a good snug fit
and secure locking nuts on clamp, you will only use as much of the 3” hose as needed to make
connection from macerator to fitting.
Step #6
Install Part (E) 20ft 1” blue discharge hose to macerator using part (G) 1” hose clamp. Note: If
your compartment is not large enough for storage of hose simply drill a 1/1/2” hole from
compartment that macerator is mounted to nearest compartment that will hold hose.
Remember once the material is in the macerator it is now under pressure and requires no more
gravity. This is also true for 5th wheels and trailer installs just plumb the hose to the
compartment you wish to store hose in. Keep in mind you want to keep hose on same side of
unit as switch and macerator.
Step #7
Now that everything is hooked up you can complete hooking up the power to macerator using
part (M) 10ga wire connectors. See wiring diagram.
  • Page 1 1