Whirlpool AKM 473/IX Program Chart

Type
Program Chart
AKM 473 PRODUCT DESCRIPTION SHEET
IT
5019 319 66024/B
Operation of burners with safety
device and electric ignition
To light one of the burners:
Press the relative knob and turn it anti-clockwise
to the large flame and star setting .
At the same time, hold the knob down until the
burner ignites.
After the burner has ignited, keep the knob
pressed for about 10 seconds.
Release the knob.
If the burner does not ignite, repeat the operations
described above.
Note:
Should particular local conditions of the
delivered gas make ignition of the burner
difficult, it is advisable to repeat the
operation with the knob turned to the small
flame setting .
The burner safety device shuts off the gas
supply to the burner if the flame goes out
accidentally (because of a sudden draught,
an interruption in the gas delivery, boiling
over of liquids, etc.).
The separator panel, positioned beneath the
cooktop at a minimum distance of 20 mm,
must be sealed.
1.
Removable grids
2-5.
Medium burners
3-6.
Large burners
4.
Auxiliary burner
7.
Control knob for front, left burner
8.
Control knob for rear, left burner
9.
Control knob for central burner
10.
Control knob for rear, right burner
11.
Control knob for front, right burner
Symbols
Shaded
circle
Tap closed
Large flame
and star
Maximum opening/
delivery and electric
ignition
Small flame
Minimum opening or
reduced delivery
A wooden shelf must be
installed below the cooktop
with a minimum thickness of 20
mm, at least 15 mm from the
bottom of the surface itself.
3gb66024b.fm Page 1 Monday, July 14, 2003 3:49 PM
DIMENSIONS OF COOKING HOB AND WORKTOP (mm)
NOTES: If the distance A between the wall cabinets is between 600 mm and 680 mm, the
height B must be a minimum of 520 mm.
If the distance A between the wall cabinets is greater than the width of the
cooktop, the height B must be a minimum of 400 mm.
Before installing a hood above the cooktop please refer to the hood instructions,
which specify the correct distance.
INJECTORS TABLE CATEGORY II2H3+
Type of gas used Type of
burner
Injector
marking
Rated heat
capacity
Pcs-kW
Rated
consumption
Reduced
heat
capacity
Pcs-kW
Gas pressure mbar
min. rat. max.
NATURAL GAS
(Methane) G20
large
medium
small
129
101
77
3.00
1.75
1.00
286 l/h
167 l/h
95 l/h
0.80
0.50
0.50
17 20 25
LIQUID PETROLEUM GAS
(Cylinder) G30
large
medium
small
87
66
50
3.00
1.75
1.00
218 g/h
127 g/h
73 g/h
0.80
0.50
0.50
20 28-30 35
LIQUID PETROLEUM GAS
(Cylinder) G31
large
medium
small
87
66
50
3.00
1.75
1.00
218 g/h
127 g/h
73 g/h
0.80
0.50
0.50
25 37 45
Type of gas used Appliance model Total rated heat
capacity Pcs-kW
Total rated
consumption
Air required for
burning m
3
/h
G20 20 mbar 5 gas 10.5 1001 l/h 21
G30 28-30 mbar 5 gas 10.5 763 g/h 21
G31 37 mbar 5 gas 10.5 763 g/h 21
3gb66024b.fm Page 2 Monday, July 14, 2003 3:49 PM